In this paper, we describe the XENON100 data analyses used to assess the
target-intrinsic background sources radon ($^{222}$Rn), thoron ($^{220}$Rn) and
krypton ($^{85}$Kr). We detail the event selections of high-energy alpha
particles and decay-specific delayed coincidences. We derive distributions of
the individual radionuclides inside the detector and quantify their abundances
during the main three science runs of the experiment over a period of $\sim$ 4
years, from January 2010 to January 2014. We compare our results to external
measurements of radon emanation and krypton concentrations where we find good
agreement. We report an observed reduction in concentrations of radon daughters
that we attribute to the plating-out of charged ions on the negatively biased
cathode.
-
We report on the response of liquid xenon to low energy electronic recoils
below 15 keV from beta decays of tritium at drift fields of 92 V/cm, 154 V/cm
and 366 V/cm using the XENON100 detector. A data-to-simulation fitting method
based on Markov Chain Monte Carlo is used to extract the photon yields and
recombination fluctuations from the experimental data. The photon yields
measured at the two lower fields are in agreement with those from literature;
additional measurements at a higher field of 366 V/cm are presented. The
electronic and nuclear recoil discrimination as well as its dependence on the
drift field and photon detection efficiency are investigated at these low
energies. The results provide new measurements in the energy region of interest
for dark matter searches using liquid xenon.
-
We report the first dark matter search results from XENON1T, a
$\sim$2000-kg-target-mass dual-phase (liquid-gas) xenon time projection chamber
in operation at the Laboratori Nazionali del Gran Sasso in Italy and the first
ton-scale detector of this kind. The blinded search used 34.2 live days of data
acquired between November 2016 and January 2017. Inside the (1042$\pm$12) kg
fiducial mass and in the [5, 40] $\mathrm{keV}_{\mathrm{nr}}$ energy range of
interest for WIMP dark matter searches, the electronic recoil background was
$(1.93 \pm 0.25) \times 10^{-4}$ events/(kg $\times$ day $\times
\mathrm{keV}_{\mathrm{ee}}$), the lowest ever achieved in a dark matter
detector. A profile likelihood analysis shows that the data is consistent with
the background-only hypothesis. We derive the most stringent exclusion limits
on the spin-independent WIMP-nucleon interaction cross section for WIMP masses
above 10 GeV/c${}^2$, with a minimum of 7.7 $\times 10^{-47}$ cm${}^2$ for
35-GeV/c${}^2$ WIMPs at 90% confidence level.
-
We present results of searches for vector and pseudo-scalar bosonic
super-WIMPs, which are dark matter candidates with masses at the keV-scale,
with the XENON100 experiment. XENON100 is a dual-phase xenon time projection
chamber operated at the Laboratori Nazionali del Gran Sasso. A profile
likelihood analysis of data with an exposure of 224.6 live days $\times$ 34\,kg
showed no evidence for a signal above the expected background. We thus obtain
new and stringent upper limits in the $(8-125)$\,keV/c$^2$ mass range,
excluding couplings to electrons with coupling constants of $g_{ae} >
3\times10^{-13}$ for pseudo-scalar and $\alpha'/\alpha > 2\times10^{-28}$ for
vector super-WIMPs, respectively. These limits are derived under the assumption
that super-WIMPs constitute all of the dark matter in our galaxy.
-
The XENON1T experiment at the Laboratori Nazionali del Gran Sasso (LNGS) is
the first WIMP dark matter detector operating with a liquid xenon target mass
above the ton-scale. Out of its 3.2t liquid xenon inventory, 2.0t constitute
the active target of the dual-phase time projection chamber. The scintillation
and ionization signals from particle interactions are detected with
low-background photomultipliers. This article describes the XENON1T instrument
and its subsystems as well as strategies to achieve an unprecedented low
background level. First results on the detector response and the performance of
the subsystems are also presented.
-
We describe the purification of xenon from traces of the radioactive noble
gas radon using a cryogenic distillation column. The distillation column is
integrated into the gas purification loop of the XENON100 detector for online
radon removal. This enabled us to significantly reduce the constant $^{222}$Rn
background originating from radon emanation. After inserting an auxiliary
$^{222}$Rn emanation source in the gas loop, we determined a radon reduction
factor of R > 27 (95% C.L.) for the distillation column by monitoring the
$^{222}$Rn activity concentration inside the XENON100 detector.
-
The XENON1T experiment aims for the direct detection of dark matter in a
cryostat filled with 3.3 tons of liquid xenon. In order to achieve the desired
sensitivity, the background induced by radioactive decays inside the detector
has to be sufficiently low. One major contributor is the $\beta$-emitter
$^{85}$Kr which is an intrinsic contamination of the xenon. For the XENON1T
experiment a concentration of natural krypton in xenon $\rm{^{nat}}$Kr/Xe < 200
ppq (parts per quadrillion, 1 ppq = 10$^{-15}$ mol/mol) is required. In this
work, the design of a novel cryogenic distillation column using the common
McCabe-Thiele approach is described. The system demonstrated a krypton
reduction factor of 6.4$\cdot$10$^5$ with thermodynamic stability at process
speeds above 3 kg/h. The resulting concentration of $\rm{^{nat}}$Kr/Xe < 26 ppq
is the lowest ever achieved, almost one order of magnitude below the
requirements for XENON1T and even sufficient for future dark matter experiments
using liquid xenon, such as XENONnT and DARWIN.
-
We report on WIMP search results in the XENON100 detector using a
non-relativistic effective field theory approach. The data from science run II
(34 kg $\times$ 224.6 live days) was re-analyzed, with an increased recoil
energy interval compared to previous analyses, ranging from $(6.6 -
240)~\mathrm{keV_\mathrm{nr}}$. The data is found to be compatible with the
background-only hypothesis. We present 90% confidence level exclusion limits on
the coupling constants of WIMP-nucleon effective operators using a binned
profile likelihood method. We also consider the case of inelastic WIMP
scattering, where incident WIMPs may up-scatter to a higher mass state, and set
exclusion limits on this model as well.
-
The XENON1T dark matter experiment aims to detect Weakly Interacting Massive
Particles (WIMPs) through low-energy interactions with xenon atoms. To detect
such a rare event necessitates the use of radiopure materials to minimize the
number of background events within the expected WIMP signal region. In this
paper we report the results of an extensive material radioassay campaign for
the XENON1T experiment. Using gamma-ray spectroscopy and mass spectrometry
techniques, systematic measurements of trace radioactive impurities in over one
hundred samples within a wide range of materials were performed. The measured
activities allowed for stringent selection and placement of materials during
the detector construction phase and provided the input for XENON1T detection
sensitivity estimates through Monte Carlo simulations.
-
We present the first constraints on the spin-dependent, inelastic scattering
cross section of Weakly Interacting Massive Particles (WIMPs) on nucleons from
XENON100 data with an exposure of 7.64$\times$10$^3$\,kg\,day. XENON100 is a
dual-phase xenon time projection chamber with 62\,kg of active mass, operated
at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy and designed to
search for nuclear recoils from WIMP-nucleus interactions. Here we explore
inelastic scattering, where a transition to a low-lying excited nuclear state
of $^{129}$Xe is induced. The experimental signature is a nuclear recoil
observed together with the prompt de-excitation photon. We see no evidence for
such inelastic WIMP-$^{129}$Xe interactions. A profile likelihood analysis
allows us to set a 90\% C.L. upper limit on the inelastic, spin-dependent
WIMP-nucleon cross section of $3.3 \times 10^{-38}$\,cm$^{2}$ at
100\,GeV/c$^2$. This is the most constraining result to date, and sets the
pathway for an analysis of this interaction channel in upcoming, larger
dual-phase xenon detectors.
-
We present the first search for dark matter-induced delayed coincidence
signals in a dual-phase xenon time projection chamber, using the 224.6\,live
days of the XENON100 science run~II. This very distinct signature is predicted
in the framework of magnetic inelastic dark matter which has been proposed to
reconcile the modulation signal reported by the DAMA/LIBRA collaboration with
the null results from other direct detection experiments. No candidate event
has been found in the region of interest and upper limits on the WIMP's
magnetic dipole moment are derived. The scenarios proposed to explain the
DAMA/LIBRA modulation signal by magnetic inelastic dark matter interactions of
WIMPs with masses of 58.0\,GeV/c$^2$ and 122.7\,GeV/c$^2$ are excluded at
3.3\,$\sigma$ and 9.3\,$\sigma$, respectively.
-
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For $^{124}$Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of $^{124}$Xe using
7636 kg$\cdot$d of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life $T_{1/2}>6.5\times10^{20}$
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
$T_{1/2}>6.1\times10^{22}$ yr after an exposure of 2 t$\cdot$yr.
-
We report on WIMP search results of the XENON100 experiment, combining three
runs summing up to 477 live days from January 2010 to January 2014. Data from
the first two runs were already published. A blind analysis was applied to the
last run recorded between April 2013 and January 2014 prior to combining the
results. The ultra-low electromagnetic background of the experiment, ~$5 \times
10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic
recoil rejection, together with the increased exposure of 48 kg $\times$ yr
improves the sensitivity. A profile likelihood analysis using an energy range
of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic,
spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8
GeV/$c^2$, with a minimum of 1.1 $\times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and
90% confidence level. We also report updated constraints on the elastic,
spin-dependent WIMP-nucleon cross sections obtained with the same data. We set
upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0
$\times 10^{-40}$ cm$^2$ (52$\times 10^{-40}$ cm$^2$) at a WIMP mass of 50
GeV/$c^2$, at 90% confidence level.
-
We report on a search for electronic recoil event rate modulation signatures
in the XENON100 data accumulated over a period of 4 years, from January 2010 to
January 2014. A profile likelihood method, which incorporates the stability of
the XENON100 detector and the known electronic recoil background model, is used
to quantify the significance of periodicity in the time distribution of events.
There is a weak modulation signature at a period of $431^{+16}_{-14}$ days in
the low energy region of $(2.0-5.8)$ keV in the single scatter event sample,
with a global significance of $1.9\,\sigma$, however no other more significant
modulation is observed. The expected annual modulation of a dark matter signal
is not compatible with this result. Single scatter events in the low energy
region are thus used to exclude the DAMA/LIBRA annual modulation as being due
to dark matter electron interactions via axial vector coupling at
$5.7\,\sigma$.
-
We present the first results of searches for axions and axion-like-particles
with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$,
has been probed by exploiting the axio-electric effect in liquid xenon. A
profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has
shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times
10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on
this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions
heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For
axion-like-particles, under the assumption that they constitute the whole
abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than
$1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set
the best limit to date as well.
-
We perform a low-mass dark matter search using an exposure of
30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a
scintillation signal and using only the ionization signal to determine the
interaction energy, we lowered the energy threshold for detection to 0.7\,keV
for nuclear recoils. No dark matter detection can be claimed because a complete
background model cannot be constructed without a primary scintillation signal.
Instead, we compute an upper limit on the WIMP-nucleon scattering cross section
under the assumption that every event passing our selection criteria could be a
signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a
limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs
with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\%
confidence level.
-
The XENON1T experiment is currently in the commissioning phase at the
Laboratori Nazionali del Gran Sasso, Italy. In this article we study the
experiment's expected sensitivity to the spin-independent WIMP-nucleon
interaction cross section, based on Monte Carlo predictions of the electronic
and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$,
$12$) keV electronic recoil equivalent energy region, before applying any
selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm
0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the
decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil
background in the corresponding nuclear recoil equivalent energy region ($4$,
$50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from
radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from
coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$
from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio
method, after converting the deposited energy of electronic and nuclear recoils
into the scintillation and ionization signals seen in the detector. We take
into account the systematic uncertainties on the photon and electron emission
model, and on the estimation of the backgrounds, treated as nuisance
parameters. The main contribution comes from the relative scintillation
efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs
and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial
volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$
cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
-
Laboratory experiments searching for galactic dark matter particles
scattering off nuclei have so far not been able to establish a discovery. We
use data from the XENON100 experiment to search for dark matter interacting
with electrons. With no evidence for a signal above the low background of our
experiment, we exclude a variety of representative dark matter models that
would induce electronic recoils. For axial-vector couplings to electrons, we
exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2
GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as
explanation for the long-standing DAMA/LIBRA signal, such as couplings to
electrons through axial-vector interactions at a 4.4 sigma confidence level,
mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
-
We have searched for periodic variations of the electronic recoil event rate
in the (2-6) keV energy range recorded between February 2011 and March 2012
with the XENON100 detector, adding up to 224.6 live days in total. Following a
detailed study to establish the stability of the detector and its background
contributions during this run, we performed an un-binned profile likelihood
analysis to identify any periodicity up to 500 days. We find a global
significance of less than 1 sigma for all periods suggesting no statistically
significant modulation in the data. While the local significance for an annual
modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and
the phase of the modulation disfavor a dark matter interpretation. The
DAMA/LIBRA annual modulation interpreted as a dark matter signature with
axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
-
Experiments searching for weak interacting massive particles with noble gases
such as liquid argon require very low detection thresholds for nuclear recoils.
A determination of the scintillation efficiency is crucial to quantify the
response of the detector at low energy. We report the results obtained with a
small liquid argon cell using a monoenergetic neutron beam produced by a
deuterium-deuterium fusion source. The light yield relative to electrons was
measured for six argon recoil energies between 11 and 120 keV at zero electric
drift field.
-
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.
-
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.
-
The XENON100 dark matter experiment uses liquid xenon in a time projection
chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of
dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we
report the observation of single-electron charge signals which are not related
to WIMP interactions. These signals, which show the excellent sensitivity of
the detector to small charge signals, are explained as being due to the
photoionization of impurities in the liquid xenon and of the metal components
inside the TPC. They are used as a unique calibration source to characterize
the detector. We explain how we can infer crucial parameters for the XENON100
experiment: the secondary-scintillation gain, the extraction yield from the
liquid to the gas phase and the electron drift velocity.
-
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso,
aims at the direct detection of dark matter in the form of weakly interacting
massive particles (WIMPs), based on their interactions with xenon nuclei in an
ultra low background dual-phase time projection chamber. This paper describes
the general methods developed for the analysis of the XENON100 data. These
methods have been used in the 100.9 and 224.6 live days science runs from which
results on spin-independent elastic, spin-dependent elastic and inelastic
WIMP-nucleon cross-sections have already been reported.
-
Results from the nuclear recoil calibration of the XENON100 dark matter
detector installed underground at the Laboratori Nazionali del Gran Sasso
(LNGS), Italy are presented. Data from measurements with an external 241AmBe
neutron source are compared with a detailed Monte Carlo simulation which is
used to extract the energy dependent charge-yield Qy and relative scintillation
efficiency Leff. A very good level of absolute spectral matching is achieved in
both observable signal channels - scintillation S1 and ionization S2 - along
with agreement in the 2-dimensional particle discrimination space. The results
confirm the validity of the derived signal acceptance in earlier reported dark
matter searches of the XENON100 experiment.