We examine the sensitivity of a large scale two-phase liquid argon detector
to the directionality of the dark matter signal. This study was performed under
the assumption that, above 50 keV of recoil energy, one can determine (with
some resolution) the direction of the recoil nucleus without head-tail
discrimination, as suggested by past studies that proposed to exploit the
dependence of columnar recombination on the angle between the recoil nucleus
direction and the electric field. In this paper we study the differential
interaction recoil rate as a function of the recoil direction angle with
respect to the zenith for a detector located at the Laboratori Nazionali del
Gran Sasso and we determine its diurnal and seasonal modulation. Using a
likelihood-ratio based approach we show that, with the angular information
alone, 100 events are enough to reject the isotropic hypothesis at three
standard deviation level. For an exposure of 100 tonne years this would
correspond to a spin independent WIMP-nucleon cross section of about 10^-46
cm^2 at 200 GeV WIMP mass. The results presented in this paper provide strong
motivation for the experimental determination of directional recoil effects in
two-phase liquid argon detectors.
-
We present the results of a search for dark matter WIMPs in the mass range
below 20 GeV/c^2 using a target of low-radioactivity argon. The data were
obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso
(LNGS). The analysis is based on the ionization signal, for which the
DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The
observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and
is almost entirely accounted for by known background sources. We obtain a 90%
C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section
of dark matter WIMPs on nucleons, extending the exclusion region for dark
matter below previous limits in the range 1.8-6 GeV/c^2.
-
We present new constraints on sub-GeV dark matter particles scattering off
electrons in argon based on an analysis of ionization signal data from the
DarkSide-50 detector.
-
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon
time projection chamber operating at Laboratori Nazionali del Gran Sasso. This
paper reports on the blind analysis and spin-independent dark matter-nucleon
coupling results from a 532.4 live-days exposure, using a target of
low-radioactivity argon extracted from underground sources. The background-free
result in the dark matter selection box gave no evidence for dark matter. The
present blind analysis sets a 90% C.L. upper limit on the dark matter-nucleon
spin-independent cross section of 1.1E-44 cm^2 (3.8E-44 cm^2, 3.4E-43 cm^2) for
a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10 TeV/c^2).
-
We report the measurement of the longitudinal diffusion constant in liquid
argon with the DarkSide-50 dual-phase time projection chamber. The measurement
is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using
high statistics $^{39}$Ar decays from atmospheric argon. We derive an
expression to describe the pulse shape of the electroluminescence signal (S2)
in dual-phase TPCs. The derived S2 pulse shape is fit to events from the
uppermost portion of the TPC in order to characterize the radial dependence of
the signal. The results are provided as inputs to the measurement of the
longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04)
cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift
field and 2.8kV/cm extraction field. To study the systematics of our
measurement we examine datasets of varying event energy, field strength, and
detector volume yielding a weighted average value for the diffusion constant of
(4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is
observed to have an energy dependence, and within the studied energy range the
result is systematically lower than other results in the literature.
-
This paper describes the design, fabrication, commissioning and use of a
CALibration source Insertion System (CALIS) in the DarkSide-50 direct dark
matter search experiment. CALIS deploys radioactive sources into the liquid
scintillator veto to characterize the detector response and detection
efficiency of the DarkSide-50 Liquid Argon Time Projection Chamber, and the
surrounding 30 t organic liquid scintillator neutron veto. It was commissioned
in September 2014 and has been used successfully in several gamma and neutron
source campaigns since then. A description of the hardware and an excerpt of
calibration analysis results are given below.
-
A Geant4-based Monte Carlo package named G4DS has been developed to simulate
the response of DarkSide-50, an experiment operating since 2013 at LNGS,
designed to detect WIMP interactions in liquid argon. In the process of WIMP
searches, DarkSide-50 has achieved two fundamental milestones: the rejection of
electron recoil background with a power of ~10^7, using the pulse shape
discrimination technique, and the measurement of the residual 39Ar
contamination in underground argon, ~3 orders of magnitude lower with respect
to atmospheric argon. These results rely on the accurate simulation of the
detector response to the liquid argon scintillation, its ionization, and
electron-ion recombination processes. This work provides a complete overview of
the DarkSide Monte Carlo and of its performance, with a particular focus on
PARIS, the custom-made liquid argon response model.
-
We report on the cryogenic characterization of Red Green Blue - High Density
(RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the
DarkSide program of dark matter searches with liquid argon time projection
chambers. A dedicated setup was used to measure the primary dark noise, the
correlated noise, and the gain of the SiPMs at varying temperatures. A
custom-made data acquisition system and analysis software were used to
precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs
with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300
K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a
few Hz/mm$^2$.
-
Building on the successful experience in operating the DarkSide-50 detector,
the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP
search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC)
with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be
deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV)
inside a cylindrical Water Cherenkov Veto (WCV). Operation of DarkSide-50
demonstrated a major reduction in the dominant $^{39}$Ar background when using
argon extracted from an underground source, before applying pulse shape
analysis. Data from DarkSide-50, in combination with MC simulation and
analytical modeling, shows that a rejection factor for discrimination between
electron and nuclear recoils of $\gt3\times10^9$ is achievable. This, along
with the use of the veto system, is the key to unlocking the path to large
LArTPC detector masses, while maintaining an "instrumental background-free"
experiment, an experiment in which less than 0.1 events (other than
$\nu$-induced nuclear recoils) is expected to occur within the WIMP search
region during the planned exposure. DarkSide-20k will have ultra-low
backgrounds than can be measured in situ. This will give sensitivity to
WIMP-nucleon cross sections of $1.2\times10^{-47}$ cm$^2$ ($1.1\times10^{-46}$
cm$^2$) for WIMPs of $1$ TeV$/c^2$ ($10$ TeV$/c^2$) mass, to be achieved during
a 5 yr run producing an exposure of 100 t yr free from any instrumental
background. DarkSide-20k could then extend its operation to a decade,
increasing the exposure to 200 t yr, reaching a sensitivity of
$7.4\times10^{-48}$ cm$^2$ ($6.9\times10^{-47}$ cm$^2$) for WIMPs of $1$
TeV$/c^2$ ($10$ TeV$/c^2$) mass.
-
Measurements were made of scintillation light yield of alpha particles from
the $^{222}$Rn decay chain within the DarkSide-50 liquid argon time projection
chamber. The light yield was found to increase as the applied electric field
increased, with alphas in a 200 V/cm electric field exhibiting a 2% increase in
light yield compared to alphas in no field.
-
DarkSide-50 is a detector for dark matter candidates in the form of weakly
interacting massive particles (WIMPs). It utilizes a liquid argon time
projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded
by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV).
The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic
muon veto detectors for DarkSide-50. This paper describes the electronics and
data acquisition system used for these two detectors.
-
Liquid argon is a bright scintillator with potent particle identification
properties, making it an attractive target for direct-detection dark matter
searches. The DarkSide-50 dark matter search here reports the first WIMP search
results obtained using a target of low-radioactivity argon. DarkSide-50 is a
dark matter detector, using two-phase liquid argon time projection chamber,
located at the Laboratori Nazionali del Gran Sasso. The underground argon is
shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3
relative to atmospheric argon. We report a background-free null result from
(2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with
our previous search using an atmospheric argon, the 90 % C.L. upper limit on
the WIMP-nucleon spin-independent cross section based on zero events found in
the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43
cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
-
Nuclear recoil events produced by neutron scatters form one of the most
important classes of background in WIMP direct detection experiments, as they
may produce nuclear recoils that look exactly like WIMP interactions. In
DarkSide-50, we both actively suppress and measure the rate of neutron-induced
background events using our neutron veto, composed of a boron-loaded liquid
scintillator detector within a water Cherenkov detector. This paper is devoted
to the description of the neutron veto system of DarkSide-50, including the
detector structure, the fundamentals of event reconstruction and data analysis,
and basic performance parameters.
-
We report the first results of DarkSide-50, a direct search for dark matter
operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and
searching for the rare nuclear recoils possibly induced by weakly interacting
massive particles (WIMPs). The dark matter detector is a Liquid Argon Time
Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t
organic liquid scintillator neutron veto, which is in turn installed at the
center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We
report here the null results of a dark matter search for a (1422+-67) kg d
exposure with an atmospheric argon fill. This is the most sensitive dark matter
search performed with an argon target, corresponding to a 90% CL upper limit on
the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP
mass of 100 GeV/c^2.
-
It is generally inferred from astronomical measurements that Dark Matter (DM)
comprises approximately 27\% of the energy-density of the universe. If DM is a
subatomic particle, a possible candidate is a Weakly Interacting Massive
Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for
evidence of WIMP-nuclear collisions. DS is located underground at the
Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three
active, embedded components; an outer water veto (CTF), a liquid scintillator
veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper
describes the data acquisition and electronic systems of the DS detectors,
designed to detect the residual ionization from such collisions.