• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • A multiball read-out for the spherical proportional counter (1707.09254)

    A. Giganon, I. Giomataris, M. Gros, I. Katsioulas, X. F. Navick, G. Tsiledakis, I. Savvidis, A. Dastgheibi-Fard, A. Brossard
    July 28, 2017 physics.ins-det
    We present a novel concept of proportional gas amplification for the read-out of the spherical proportional counter. The standard single-ball read-out presents limitations for large diameter spherical detectors and high pressure operations. We have developed a multi-ball read-out system which consists of several balls sitting at a fixed distance from the center of the spherical vessel. Such a module can tune the volume electric field at the desired value and can also provide detector segmentation with individual ball read-out. In the latter case the large volume of the vessel becomes a spherical time projection chamber with 3D capabilities.
  • The COMPASS Setup for Physics with Hadron Beams (1410.1797)

    Ph. Abbon, C. Adolph, R. Akhunzyanov, Yu. Alexandrov, M.G. Alexeev, G.D. Alexeev, A. Amoroso, V. Andrieux, V. Anosov, A. Austregesilo, B. Badelek, F. Balestra, J. Barth, G. Baum, R. Beck, Y. Bedfer, A. Berlin, J. Bernhard, K. Bicker, E.R. Bielert, J. Bieling, R. Birsa, J. Bisplinghoff, M. Bodlak, M. Boer, P. Bordalo, F. Bradamante, C. Braun, A. Bressan, M. Buechele, E. Burtin, L. Capozza, P. Ciliberti, M. Chiosso, S.U. Chung, A. Cicuttin, M. Colantoni, D. Cotte, M.L. Crespo, Q. Curiel, T. Dafni, S. Dalla Torre, S.S. Dasgupta, S. Dasgupta, O.Yu. Denisov, D. Desforge, A.M. Dinkelbach, S.V. Donskov, N. Doshita, V. Duic, W. Duennweber, D. Durand, M. Dziewiecki, A. Efremov, C. Elia, P.D. Eversheim, W. Eyrich, M. Faessler, A. Ferrero, M. Finger, M. Finger jr., H. Fischer, C. Franco, N. du Fresne von Hohenesche, J.M. Friedrich, V. Frolov, L. Gatignon, F. Gautheron, O.P. Gavrichtchouk, S. Gerassimov, R. Geyer, A. Giganon, I. Gnesi, B. Gobbo, S. Goertz, M. Gorzellik, S. Grabmueller, A. Grasso, M. Gregori, B. Grube, T. Grussenmeyer, A. Guskov, F. Haas, D. von Harrach, D. Hahne, R. Hashimoto, F.H. Heinsius, F. Herrmann, F. Hinterberger, Ch. Hoeppner, N. Horikawa, N. d'Hose, S. Huber, S. Ishimoto, A. Ivanov, Yu. Ivanshin, T. Iwata, R. Jahn, V. Jary, P. Jasinski, P. Joerg, R. Joosten, E. Kabuss, B. Ketzer, G.V. Khaustov, Yu.A. Khokhlov, Yu. Kisselev, F. Klein, K. Klimaszewski, J.H. Koivuniemi, V.N. Kolosov, K. Kondo, K. Koenigsmann, I. Konorov, V.F. Konstantinov, A.M. Kotzinian, O. Kouznetsov, M. Kraemer, Z.V. Kroumchtein, N. Kuchinski, R. Kuhn, F. Kunne, K. Kurek, R.P. Kurjata, A.A. Lednev, A. Lehmann, M. Levillain, S. Levorato, J. Lichtenstadt, A. Maggiora, A. Magnon, N. Makke, G.K. Mallot, C. Marchand, J. Marroncle, A. Martin, J. Marzec, J. Matousek, H. Matsuda, T. Matsuda, G. Menon, G. Meshcheryakov, W. Meyer, T. Michigami, Yu.V. Mikhailov, Y. Miyachi, M.A. Moinester, A. Nagaytsev, T. Nagel, F. Nerling, S. Neubert, D. Neyret, V.I. Nikolaenko, J. Novy, W.-D. Nowak, A.S. Nunes, A.G. Olshevsky, I. Orlov, M. Ostrick, R. Panknin, D. Panzieri, B. Parsamyan, S. Paul, G. Pesaro, V. Pesaro, D.V. Peshekhonov, C. Pires, S. Platchkov, J. Pochodzalla, V.A. Polyakov, J. Pretz, M. Quaresma, C. Quintans, S. Ramos, C. Regali, G. Reicherz, J-M. Reymond, E. Rocco, N.S. Rossiyskaya, J.-Y. Rousse, D.I. Ryabchikov, A. Rychter, A. Samartsev, V.D. Samoylenko, A. Sandacz, S. Sarkar, I.A. Savin, G. Sbrizzai, P. Schiavon, C. Schill, T. Schlueter, K. Schmidt, H. Schmieden, K. Schoenning, S. Schopferer, M. Schott, O.Yu. Shevchenko, L. Silva, L. Sinha, S. Sirtl, M. Slunecka, S. Sosio, F. Sozzi, A. Srnka, L. Steiger, M. Stolarski, M. Sulc, R. Sulej, H. Suzuki, A. Szabelski, T. Szameitat, P. Sznajder, S. Takekawa, J. ter Wolbeek, S. Tessaro, F. Tessarotto, F. Thibaud, V. Tskhay, S. Uhl, I. Uman, M. Virius, L. Wang, T. Weisrock, Q. Weitzel, M. Wilfert, R. Windmolders, H. Wollny, K. Zaremba, M. Zavertyaev, E. Zemlyanichkina, M. Ziembicki, A. Zink
    Oct. 7, 2014 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The main characteristics of the COMPASS experimental setup for physics with hadron beams are described. This setup was designed to perform exclusive measurements of processes with several charged and/or neutral particles in the final state. Making use of a large part of the apparatus that was previously built for spin structure studies with a muon beam, it also features a new target system as well as new or upgraded detectors. The hadron setup is able to operate at the high incident hadron flux available at CERN. It is characterised by large angular and momentum coverages, large and nearly flat acceptances, and good two and three-particle mass resolutions. In 2008 and 2009 it was successfully used with positive and negative hadron beams and with liquid hydrogen and solid nuclear targets. This article describes the new and upgraded detectors and auxiliary equipment, outlines the reconstruction procedures used, and summarises the general performance of the setup.
  • Ageing studies of resistive Micromegas detectors for the HL-LHC (1304.2053)

    J. Galan, D. Attie, E. Ferrer-Ribas, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, A. Peyaud, Ph. Schune, T. Alexopoulos, M. Byszewski, G. Iakovidis, P. Iengo, K. Ntekas, S. Leontsinis, R. de Oliveira, Y. Tsipolitis, J. Wotschack
    April 7, 2013 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    Resistive-anode Micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working in high flux and high radiations environment like in the HL-LHC (ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiations (X-rays, cold neutrons, 60 Co gammas) up to an equivalent HL-LHC time of more than five years without showing any degradation of the performances in terms of gain and energy resolution. Beam test studies took place in October 2012 to assess the tracking performances (efficiency, spatial resolution,...). Results of ageing studies and beam test performances are reported in this paper.
  • An ageing study of resistive micromegas for the HL-LHC environment (1301.7648)

    J. Galán, D. Attié, E. Ferrer-Ribas, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, A. Peyaud, Ph. Schune, T. Alexopoulos, M. Byszewski, G. Iakovidis, P. Iengo, K. Ntekas, S. Leontsinis, R. de Oliveira, Y. Tsipolitis, J. Wotschack
    Jan. 31, 2013 hep-ex, physics.ins-det, physics.acc-ph
    ... ... ... ... ... ...
    Resistive-anode micromegas detectors are in development since several years, in an effort to solve the problem of sparks when working at high flux and high ionizing radiation like in the HL-LHC (up to ten times the luminosity of the LHC). They have been chosen as one of the technologies that will be part of the ATLAS New Small Wheel project (forward muon system). An ageing study is mandatory to assess their capabilities to handle the HL-LHC environment on a long-term period. A prototype has been exposed to several types of irradiation (X-rays, cold neutrons, $^{60}$Co gammas and alphas) above the equivalent charge produced at the detector in five HL-LHC running years without showing any degradation of the performances in terms of gain and energy resolution. This study has been completed with the characterization of the tracking performances in terms of efficiency and spatial resolution, verifying the compatibility of results obtained with both resistive micromegas detectors, irradiated and non-irradiated one.
  • Performances of Anode-resistive Micromegas for HL-LHC (1202.1074)

    J. Manjarres, T. Alexopoulos, D. Attie, M.Boyer, J. Derre, G. Fanourakis, E. Ferrer-Ribas, J. Galan, E. Gazis, T. Geralis, A. Giganon, I. Giomataris, S. Herlant, F. Jeanneau, Ph. Schune, M. Titov, G. Tsipolitis (for the MAMMA Collaboration)
    Feb. 6, 2012 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of ~98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.Micromegas technology is a promising candidate to replace Atlas forward muon chambers -tracking and trigger- for future HL-LHC upgrade of the experiment. The increase on background and pile-up event probability requires detector performances which are currently under studies in intensive RD activities. We studied performances of four different resistive Micromegas detectors with different read-out strip pitches. These chambers were tested using \sim120 GeV momentum pions, at H6 CERN-SPS beam line in autumn 2010. For a strip pitch 500 micrometers we measure a resolution of \sim90 micrometers and a efficiency of \sim98%. The track angle effect on the efficiency was also studied. Our results show that resistive techniques induce no degradation on the efficiency or resolution, with respect to the standard Micromegas. In some configuration the resistive coating is able to reduce the discharge currents at least by a factor of 100.
  • Characterization of microbulk detectors in argon- and neon-based mixtures (1201.3012)

    F.J. Iguaz, E. Ferrer-Ribas, A. Giganon, I. Giomataris
    Jan. 14, 2012 hep-ex, physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    A recent Micromegas manufacturing technique, so called Microbulk, has been developed, improving the uniformity and stability of this kind of detectors. Excellent energy resolutions have been obtained, reaching values as low as 11% FWHM at 5.9 keV in Ar+5%iC4H10. This detector has other advantages like its flexible structure, low material budget and high radio-purity. Two microbulk detectors with gaps of 50 and 25 um have been characterized in argon- and neon-based mixtures with ethane, isobutane and cyclohexane. The results will be presented and discussed. The gain curves have been fitted to the Rose-Korff gain model and dependences of the electron mean free path and the threshold energy for ionization have been obtained. The possible relation between these two parameters and the energy resolution will be also discussed.
  • Performances and ageing study of resistive-anodes Micromegas detectors for HL-LHC environment (1201.1843)

    F. Jeanneau, T. Alexopoulos, D. Attié, M. Boyer, J. Derré, G. Fanourakis, E. Ferrer-Ribas, J. Galán, E. Gazis, T. Geralis, A. Giganon, I. Giomataris, S. Herlant, J. Manjarrés, E. Ntomari, Ph. Schune, M. Titov, G. Tsipolitis
    Jan. 9, 2012 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    With the tenfold luminosity increase envisaged at the HL-LHC, the background (photons, neutrons, ...) and the event pile-up probability are expected to increase in proportion in the different experiments, especially in the forward regions like, for instance, the muons chambers of the ATLAS detector. Detectors based on the Micromegas principle should be good alternatives for the detector upgrade in the HL-LHC framework because of a good spatial (<100 \mum) and time (few ns) resolutions, high-rate capability, radiation hardness, good robustness and the possibility to build large areas. The aim of this study is to demonstrate that it is possible to reduce the discharge probability and protect the electronics by using a resistive anode plane in a high flux hadrons environment. Several prototypes of 10x10 cm2, with different pitches (0.5 to 2 mm) and different resistive layers have been tested at CERN (pi+@SPS). Several tests have been performed with a telescope at different voltages to assess the performances of the detectors in terms of position resolution and efficiency. The spark behaviour in these conditions has also been evaluated. Resistive coating has been shown to be a successful method to reduce the effect of sparks on the efficiency of micromegas. A good spatial resolution (~80 \mum) can be reached with a resistive strip coating detector of 1mm pitch and a high efficiency (> 98%) can be achieved with resistive-anode micromegas detector. An X-rays irradiation has been also performed, showing no ageing effect after more than 21 days exposure and an integrated charge of almost 1C.
  • Aging studies of Micromegas prototypes for the HL-LHC (1111.5998)

    J. Galan, D. Attie, J. Derre, E. Ferrer Ribas, A. Giganon, I. Giomataris, F. Jeanneau, J. Manjarres, R. de Oliveira, P. Schune, M. Titov, J. Wotschack
    Nov. 25, 2011 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The micromegas technology is a promising candidate to replace the forward muon chambers for the luminosity upgrade of ATLAS. The LHC accelerator luminosity will be five times the nominal one, increasing background and pile-up event probability. This requires detector performances which are currently under study in intensive R&D activities. Aging is one of the key issues for a high-luminosity LHC application. For this reason, we study the properties of resistive micromegas detectors under intense X-ray radiation and under thermal neutrons in different CEA-Saclay facilities. This study is complementary to those already performed using fast neutrons.
  • Neutron imaging with a Micromegas detector (physics/0607191)

    F. Jeanneau, R. Junca, J. Pancin, M. Voytchev, S. Andriamonje, V. Dangendorf, I. Espagnon, H. Friedrich, A. Giganon, I. Giomataris, A. Menelle, A. Pluquet, L. R. Rodriguez
    July 21, 2006 physics.ins-det
    The micropattern gaseous detector Micromegas has been developed for several years in Saclay and presents good performance for neutron detection. A prototype for neutron imaging has been designed and new results obtained in thermal neutron beams are presented. Based on previous results demonstrating a good 1D spatial resolution, a tomographic image of a multiwire cable has been performed using a 1D Micromegas prototype. The number of pillars supporting the micromesh is too large and leads to local losses of efficiency that distort the tomographic reconstruction. Nevertheless, this first tomographic image achieved with this kind of detector is very encouraging. The next worthwhile development for neutron imaging is to achieve a bi-dimensional detector, which is presented in the second part of this study. The purpose of measurements was to investigate various operational parameters to optimize the spatial resolution. Through these measurements the optimum spatial resolution has been found to be around 160 microns (standard deviation) using Micromegas operating in double amplification mode. Several 2D imaging tests have been carried out. Some of these results have revealed fabrication defects that occurred during the manufacture of Micromegas and that are limiting the full potential of the present neutron imaging system.
  • Performance of the Micromegas detector in the CAST experiment (physics/0512094)

    S. Aune, T. Dafni, G. Fanourakis, E. Ferrer Ribas, T. Geralis, A. Giganon, Y. Giomataris, I. G. Irastorza, K. Kousouris, K. Zachariadou
    Dec. 12, 2005 physics.ins-det
    The gaseous Micromegas detector designed for the CERN Axion search experiment CAST, operated smoothly during Phase-I, which included the 2003 and 2004 running periods. It exhibited linear response in the energy range of interest (1-10keV), good spatial sensitivity and energy resolution (15-19% FWHM at 5.9keV)as well as remarkable stability. The detector's upgrade for the 2004 run, supported by the development of advanced offline analysis tools, improved the background rejection capability, leading to an average rate 5x10^-5 counts/sec/cm^2/keV with 94% cut efficiency. Also, the origin of the detected background was studied with a Monte Carlo simulation, using the GEANT4 package.
  • A low background Micromegas detector for the CAST experiment (physics/0510258)

    P. Abbon, S. Andriamonje, S. Aune, D. Besin, S. Cazaux, P. Contrepois, T. Dafni, T. Decker, N. Duportail, G. Fanourakis, E. Ferrer Ribas, T. Geralis, A. Giganon, I. Giomataris, M. Gros, R. Hill, I. G. Irastorza, K. Kousouris, J. Morales, M. Pivovaroff, M. Riallot, R. Soufli, K. Zachariadou, G. Zaffanela
    Oct. 28, 2005 physics.ins-det
    A low background Micromegas detector has been operating on the CAST experiment at CERN for the search of solar axions during the first phase of the experiment (2002-2004). The detector operated efficiently and achieved a very low level of background rejection ($5\times 10^{-5}$ counts keV$^{-1}$cm$^{-2}$s$^{-1}$) thanks to its good spatial and energy resolution as well as the low radioactivity materials used in the construction of the detector. For the second phase of the experiment (2005-2007), the detector will be upgraded by adding a shielding and including focusing optics. These improvements should allow for a background rejection better than two orders of magnitude.
  • Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal (physics/0510085)

    A. Bellerive, K. Boudjemline, R. Carnegie, M. Dixit, J. Miyamoto, E. Neuheimer, A. Rankin, E. Rollin, K. Sachs, J.-P. Martin, V. Lepeltier, P. Colas, A. Giganon, I. Giomataris
    Oct. 11, 2005 physics.ins-det
    The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $\mu$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. The charge dispersion studies were repeated with a Micromegas TPC amplification stage. We present here our first results on the Micromegas-TPC resolution with charge dispersion. The TPC resolution with the Micromegas readout is compared to our earlier GEM results and to the resolution expected from electron statistics and transverse diffusion in a gaseous TPC.
  • Micromegas in a Bulk (physics/0501003)

    I. Giomataris, R. De Oliveira, S. Andriamonje, S. Aune, G. Charpak, P. Colas, A. Giganon, Ph. Rebourgeard, P. Salin
    Jan. 2, 2005 physics.ins-det
    In this paper we present a novel way to manufacture the bulk Micromegas detector. A simple process based on the PCB (Printed Circuit Board) technology is employed to produce the entire sensitive detector. Such fabrication process could be extended to very large area detectors made by the industry. The low cost fabrication together with the robustness of the electrode materials will make it extremely attractive for several applications ranging from particle physics and astrophysics to medicine