Plasma driven particle accelerators represent the future of compact
accelerating machines and Free Electron Lasers are going to benefit from these
new technologies. One of the main issue of this new approach to FEL machines is
the design of the transfer line needed to match of the electron-beam with the
magnetic undulators. Despite the reduction of the chromaticity of plasma beams
is one of the main goals, the target of this line is to be effective even in
cases of beams with a considerable value of chromaticity. The method here
explained is based on the code GIOTTO [1] that works using a homemade genetic
algorithm and that is capable of finding optimal matching line layouts directly
using a full 3D tracking code.
-
At EuPRAXIA@SPARC_LAB, the unique combination of an advanced high-brightness
RF injector and a plasma-based accelerator will drive a new multi-disciplinary
user-facility. The facility, that is currently under study at INFN-LNF
Laboratories (Frascati, Italy) in synergy with the EuPRAXIA collaboration, will
operate the plasma-based accelerator in the external injection configuration.
Since in this configuration the stability and reproducibility of the
acceleration process in the plasma stage is strongly influenced by the
RF-generated electron beam, the main challenge for the RF injector design is
related to generating and handling high quality electron beams. In the last
decades of R&D activity, the crucial role of high-brightness RF photo-injectors
in the fields of radiation generation and advanced acceleration schemes has
been largely established, making them effective candidates to drive
plasma-based accelerators as pilots for user facilities. An RF injector
consisting in a high-brightness S-band photo-injector followed by an advanced
X-band linac has been proposed for the EuPRAXIA@SPARC_LAB project. The electron
beam dynamics in the photo-injector has been explored by means of simulations,
resulting in high-brightness, ultra-short bunches with up to 3 kA peak current
at the entrance of the advanced X-band linac booster. The EuPRAXIA@SPARC_LAB
high-brightness photo-injector is described here together with performance
optimisation and sensitivity studies aiming to actual check the robustness and
reliability of the desired working point.
-
In this paper, we report results of simulations, in the framework of both
EuPRAXIA \cite{Walk2017} and EuPRAXIA@SPARC\_LAB \cite{Ferr2017} projects,
aimed at delivering a high brightness electron bunch for driving a Free
Electron Laser (FEL) by employing a plasma post acceleration scheme. The
boosting plasma wave is driven by a tens of \SI{}{\tera\watt} class laser and
doubles the energy of an externally injected beam up to \GeV{1}. The injected
bunch is simulated starting from a photoinjector, matched to plasma, boosted
and finally matched to an undulator, where its ability to produce FEL radiation
is verified to yield $O(\num{e11})$ photons per shot at \nm{2.7}.
-
A design study of the diagnostics of a high brightness linac, based on X-band
structures, and a plasma accelerator stage, has been delivered in the framework
of the EuPRAXIA@SPARC_LAB project. In this paper, we present a conceptual
design of the proposed diagnostics, using state of the art systems and new and
under development devices. Single shot measurements are preferable for plasma
accelerated beams, including emittance, while $\mu$m level and fs scale beam
size and bunch length respectively are requested. The needed to separate the
driver pulse (both laser or beam) from the witness accelerated bunch imposes
additional constrains for the diagnostics. We plan to use betatron radiation
for the emittance measurement just at the end of the plasma booster, while
other single-shot methods must be proven before to be implemented. Longitudinal
measurements, being in any case not trivial for the fs level bunch length, seem
to have already a wider range of possibilities.
-
Advanced linear accelerator design may use Optical Transition Radiation (OTR)
screens to measure beam spot size; for instance, such screens are foreseen in
plasma based accelerators (EuPRAXIA@SPARC_LAB) or Compton machines (Gamma Beam
Source@ELI-NP). Optical Transition Radiation angular distribution strongly
depends on beam energy. Since OTR screens are typically placed in several
positions along the Linac to monitor the beam envelope, one may perform a
distributed energy measurement along the machine. Furthermore, a single shot
energy measurement can be useful in plasma accelerators to measure shot to shot
energy variations after the plasma interaction. Preliminary measurements of OTR
angular distribution of about 100 MeV electrons have been performed at the
SPARC_LAB facility. In this paper, we discuss the sensitivity of this
measurement to beam divergence and others parameters, as well as the resolution
required and the needed upgrades of conventional OTR diagnostics, using as an
example the data collected at SPARC_LAB.
-
Beam injection and extraction from a plasma module is still one of the
crucial aspects to solve in order to produce high quality electron beams with a
plasma accelerator. Proper matching conditions require to focus the incoming
high brightness beam down to few microns size and to capture a high divergent
beam at the exit without loss of beam quality. Plasma-based lenses have proven
to provide focusing gradients of the order of kT/m with radially symmetric
focusing thus promising compact and affordable alternative to permanent magnets
in the design of transport lines. In this paper an overview of recent
experiments and future perspectives of plasma lenses is reported.
-
In the framework of the Eupraxia Design Study an advanced accelerator
facility EUPRAXIA@SPARC_LAB has been proposed to be realized at Frascati
(Italy) Laboratories of INFN. Two advanced acceleration schemes will be
applied, namely an ultimate high gradient 1 GeV X-band linac together with a
plasma acceleration stage to provide accelerating gradients of the GeV/m order.
A FEL scheme is foreseen to produce X-ray beams within 3-10 nm range. A 500-TW
Laser system is also foreseen for electron and ion production experiments and a
Compton backscattering Interaction is planned together with extraction
beamlines at intermediate electron beam energy for neutron beams and THz
radiation production. The electron beam dynamics studies in the linac are here
presented together with the preliminary machine layout.
-
On the wake of the results obtained so far at the SPARC\_LAB test-facility at
the Laboratori Nazionali di Frascati (Italy), we are currently investigating
the possibility to design and build a new multi-disciplinary user-facility,
equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV
high brightness linac based on plasma accelerator modules. This design study is
performed in synergy with the EuPRAXIA design study. In this paper we report
about the recent progresses in the on going design study of the new facility.
-
The current activity of the SPARC_LAB test-facility is focused on the
realization of plasma-based acceleration experiments with the aim to provide
accelerating field of the order of several GV/m while maintaining the overall
quality (in terms of energy spread and emittance) of the accelerated electron
bunch. In the following, the current status of such an activity is presented.
We also show results related to the usability of plasmas as focusing lenses in
view of a complete plasma-based focusing and accelerating system.
-
The interest in plasma-based accelerators as drivers of user facilities is
growing worldwide thanks to its compactness and reduced costs. In this context
the EuPRAXIA collaboration is preparing a conceptual design report for a
multi-GeV plasma-based accelerator with outstanding electron beam quality to
pilot, among several applications, the operation of an X-ray FEL, the most
demanding in terms of beam brightness. Intense beam dynamics studies have been
performed to provide a reliable working point for the RF injector to generate a
high-brightness trailing witness bunch suitable in external injection schemes,
both in particle beam and laser driven plasma wakefield acceleration. A case of
interest is the generation of a witness beam with 1 GeV energy, less than 1
mm-mrad slice emittance and 30 pC in 10 fs FWHM bunch length, which turns into
3 kA peak current at the undulator entrance. The witness beam has been
successfully compressed down to 10 fs in a conventional SPARC-like
photo-injector and boosted up to 500 MeV in an advanced high-gradient X-band
linac reaching the plasma entrance with 3 kA peak current and the following RMS
values: 0.06% energy spread, 0.5 mm-mrad transverse normalised emittance and a
focal spot down to 1 $\mu m$. RF injector studies are here presented with the
aim to satisfy the EuPRAXIA requests for the Design Study of a plasma-based
user facility.
-
R\&D activity on Cu photocathodes is under development at the SPARC\_LAB test
facility to fully characterize each stage of the photocathode "life" and to
have a complete overview of the photoemission properties in high brightness
photo-injectors. The nano(n)-machining process presented here consists in
diamond milling, and blowing with dry nitrogen. This procedure reduces the
roughness of the cathode surface and prevents surface contamination introduced
by other techniques, such as polishing with diamond paste or the machining with
oil. Both high roughness and surface contamination cause an increase of
intrinsic emittance and consequently a reduction of the overall electron beam
brightness. To quantify these effects, we have characterized the photocathode
surface in terms of roughness measurement, and morphology and chemical
composition analysis by means of Scanning Electron Microscopy (SEM), Energy
Dispersive Spectroscopy (EDS), and Atomic Force Microscopy (AFM) techniques.
The effects of n-machining on the electron beam quality have been also
investigated through emittance measurements before and after the surface
processing technique. Finally, we present preliminary emittance studies of
yttrium thin film on Cu photocathodes.