The CRESST-III experiment which is dedicated to low-mass dark matter search
uses scintillating CaWO$_4$ crystals operated as cryogenic particle detectors.
Background discrimination is achieved by exploiting the scintillating light
signal of CaWO$_4$ and by a novel active detector holder presented in this
paper. In a test setup above ground, a nuclear-recoil energy threshold of
$E_{th}=(190.6\pm5.2)$eV is reached with a 24g prototype detector, which
corresponds to an estimated threshold of $\sim$50eV when being operated in the
low-noise CRESST cryostat. This is the lowest threshold reported for direct
dark matter searches. For CRESST-III phase 1, ten such detector modules were
installed in the cryostat which have the potential to improve significantly the
sensitivity to scatterings of dark matter particles with masses down to
$\sim$0.1GeV/c$^2$.
-
Cryogenic rare event searches based on heat and light composite calorimeters
have a common need for large area photon detectors with high quantum
efficiency, good radiopurity and high sensitivity. By employing the
Neganov-Trofimov-Luke effect (NTLE), the phonon signal of particle interactions
in a semiconductor absorber operated at cryogenic temperatures can be amplified
by drifting the photogenerated electrons and holes in an electric field. We
present here the last results of a Neganov-Trofimov-Luke effect light detector
with an electric field configuration optimized to improve the charge collection
within the absorber.
-
In this work we investigate the reflectivity of highly reflective multilayer
polymer foils used in the CRESST experiment. The CRESST experiment searches
directly for dark matter via operating scintillating CaWO$_4$ crystals as
targets for elastic dark matter-nucleon scattering. In order to suppress
background events, the experiment employs the so-called phonon-light technique
which is based on the simultaneous measurement of the heat signal in the main
CaWO$_4$ target crystal and of the emitted scintillation light with a separate
cryogenic light detector. Both detectors are surrounded by a highly reflective
and scintillating multilayer polymer foil to increase the light collection
efficiency and to veto surface backgrounds. While this study is motivated by
the CRESST experiment, the results are also relevant for other rare event
searches using scintillating cryogenic bolometers in the field of the search of
dark matter and neutrinoless double beta decay ($0\nu\beta\beta$). In this work
a dedicated experiment has been set up to determine the relative reflectivity
at 300 K and 20 K of three multilayer foils ("VM2000", "VM2002", "Vikuiti")
produced by the company 3M. The intensity of a light beam reflected off the
foil is measured with a CCD camera. The ratio of the intensities at 300 K and
20 K corresponds to the relative reflectivity change. The measurements
performed in this work show no significant change in the reflectivity with
temperature for all foils studied.
-
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
-
In Phase 2 of CRESST-II 18 detector modules were operated for about two years
(July 2013 - August 2015). Together with this document we are publishing data
from two detector modules which have been used for direct dark-matter searches.
With these data-sets we were able to set world-leading limits on the cross
section for spin-independent elastic scattering of dark matter particles off
nuclei. We publish the energies of all events within the acceptance regions for
dark-matter searches. In addition, we also publish the energies of the events
within the electron-recoil band. This data set can be used to study
interactions with electrons of CaWO$_4$. In this document we describe how to
use these data sets. In particular, we explain the cut-survival probabilities
required for comparisons of models with the data sets.
-
Scintillating, cryogenic bolometers are widely used in the field of rare
event searches. Their main advantages are an excellent energy resolution and
particle identification on an event-by-event basis. The sensitivity of
experiments applying this detector technique can be limited by the performance
of the light channel and the presence of external backgrounds in the region of
interest. In the framework of the CRESST-II experiment, we developed and
successfully tested a novel detector design addressing both challenges. Using a
large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber,
the signal height recorded in the light channel is improved by a factor 2.5
compared to conventional CRESTT-II detector modules. In combination with a
large carrier crystal, a true $4\pi$ veto system is established which allows to
tag external background sources.
-
Identifying the nature and origin of dark matter is one of the major
challenges for modern astro and particle physics. Direct dark-matter searches
aim at an observation of dark-matter particles interacting within detectors.
The focus of several such searches is on interactions with nuclei as provided
e.g. by Weakly Interacting Massive Particles. However, there is a variety of
dark-matter candidates favoring interactions with electrons rather than with
nuclei. One example are dark photons, i.e., long-lived vector particles with a
kinetic mixing to standard-model photons. In this work we present constraints
on this kinetic mixing based on data from CRESST-II Phase 2 corresponding to an
exposure before cuts of 52\,kg-days. These constraints improve the existing
ones for dark-photon masses between 0.3 and 0.7\,keV/c$^2$.
-
The CRESST experiment (Cryogenic Rare Event Search with Superconducting
Thermometers) searches for dark matter via the phonon and light signals of
elastic scattering processes in scintillating crystals. The discrimination
between a possible dark matter signal and background is based on the light
yield. We present a new method for evaluating the two characteristics of a
phonon/light detector module that determine how much of the deposited energy is
converted to scintillation light and how efficiently a module detects the
produced light. In contrast to former approaches with dedicated setups, we
developed a method which allows us to use data taken with the cryogenic setup,
during a dark matter search phase. In this way, we accounted for the entire
process that occurs in a detector module, and obtained information on the light
emission of the crystal as well as information on the performance of the module
(light transport and detection). We found that with the detectors operated in
CRESST-II phase 1, about 20% of the produced scintillation light is detected. A
part of the light is likely absorbed by creating meta-stable excitations in the
scintillating crystals. The light not detected is not absorbed entirely, as an
additional light detector can help to increase the fraction of detected light.
-
The usual assumption in direct dark matter searches is to only consider the
spin-dependent or spin-independent scattering of dark matter particles.
However, especially in models with light dark matter particles
$\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the
momentum transfer $q^2$ can become dominant. One such model based on asymmetric
dark matter has been invoked to overcome discrepancies in helioseismology and
an indication was found for a particle with preferred mass of 3
$\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data
from the CRESST-II experiment, which uses cryogenic detectors based on
$\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter
particles, are used to constrain these momentum-dependent models. The low
energy threshold of 307 eV for nuclear recoils of the detector used, allows us
to rule out the proposed best fit value above.
-
The CRESST-II experiment uses cryogenic detectors to search for nuclear
recoil events induced by the elastic scattering of dark matter particles in
CaWO$_4$ crystals. Given the low energy threshold of our detectors in
combination with light target nuclei, low mass dark matter particles can be
probed with high sensitivity. In this letter we present the results from data
of a single detector module corresponding to 52 kg live days. A blind analysis
is carried out. With an energy threshold for nuclear recoils of 307 eV we
substantially enhance the sensitivity for light dark matter. Thereby, we extend
the reach of direct dark matter experiments to the sub-region and demonstrate
that the energy threshold is the key parameter in the search for low mass dark
matter particles.
-
The experiment CRESST-II aims at the detection of dark matter with
scintillating CaWO$_4$ crystals operated as cryogenic detectors. Recent results
on spin-independent WIMP-nucleon scattering from the CRESST-II Phase 2 allowed
to probe a new region of parameter space for WIMP masses below 3 GeV/c$^2$.
This sensitivity was achieved after background levels were reduced
significantly. We present extensive background studies of a CaWO$_4$ crystal,
called TUM40, grown at the Technische Universit\"at M\"unchen. The average
beta/gamma rate of 3.51/[kg keV day] (1-40 keV) and the total intrinsic alpha
activity from natural decay chains of $3.08\pm0.04$ mBq/kg are the lowest
reported for CaWO$_4$ detectors. Contributions from cosmogenic activation,
surface-alpha decays, external radiation and intrinsic alpha/beta emitters are
investigated in detail. A Monte-Carlo based background decomposition allows to
identify the origin of the majority of beta/gamma events in the energy region
relevant for dark matter search.
-
The cryogenic dark matter experiment CRESST-II aims at the direct detection
of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals.
We present a new, highly improved, detector design installed in the current run
of CRESST-II Phase 2 with an efficient active rejection of surface-alpha
backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target
crystal, a detector housing with fully-scintillating inner surface could be
realized. The presented detector (TUM40) provides an excellent threshold of
${\sim}\,0.60\,$keV and a resolution of $\sigma\,{\approx}\,0.090$ keV (at
2.60$\,$keV). With significantly reduced background levels, TUM40 sets
stringent limits on the spin-independent WIMP-nucleon scattering cross section
and probes a new region of parameter space for WIMP masses below
3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the
surface-alpha event rejection in detail.
-
Scintillating CaWO$_4$ single crystals are a promising multi-element target
for rare-event searches and are currently used in the direct Dark Matter
experiment CRESST (Cryogenic Rare Event Search with Superconducting
Thermometers). The relative light output of different particle interactions in
CaWO$_4$ is quantified by Quenching Factors (QFs). These are essential for an
active background discrimination and the identification of a possible signal
induced by weakly interacting massive particles (WIMPs). We present the first
precise measurements of the QFs of O, Ca and W at mK temperatures by
irradiating a cryogenic detector with a fast neutron beam. A clear energy
dependence of the QF of O and, less pronounced, of Ca was observed for the
first time. Furthermore, in CRESST neutron-calibration data a variation of the
QFs among different CaWO$_4$ single crystals was found. For typical CRESST
detectors the QFs in the region-of-interest (10-40$\,$keV) are
$QF_O^{ROI}=(11.2{\pm}0.5)\,$%, $QF_{Ca}^{ROI}=(5.94{\pm}0.49)\,$% and
$QF_W^{ROI}=(1.72{\pm}0.21)\,$%. The latest CRESST data (run32) is reanalyzed
using these fundamentally new results on light quenching in CaWO$_4$ having
moderate influence on the WIMP analysis. Their relevance for future CRESST runs
and for the clarification of previously published results of direct Dark Matter
experiments is emphasized.
-
In prospect of its application in cryogenic rare-event searches, we have
investigated the low-temperature scintillation properties of CaWO4 crystals
down to 3.4 K under {\alpha} and {\gamma} excitation. Concerning the
scintillation decay times, we observe a long component in the ms range which
significantly contributes to the light yield below 40K. For the first time we
have measured the temperature dependence of the {\alpha}/{\gamma}- ratio of the
light yield. This parameter which can be used to discriminate {\alpha} and
{\gamma} events in scintillating bolometers is found to be about 8-15% smaller
at low temperatures compared to room temperature.
-
In the past years the spotlight of the search for dark matter particles
widened to the low mass region, both from theoretical and experimental side. We
discuss results from data obtained in 2013 with a single detector TUM40. This
detector is equipped with a new upgraded holding scheme to efficiently veto
backgrounds induced by surface alpha decays. This veto, the low threshold of
0.6keV and an unprecedented background level for CaWO$_4$ target crystals
render TUM40 the detector with the best overall performance of CRESST-II phase
2 (July 2013 - August 2015). A low-threshold analysis allowed to investigate
light dark matter particles (<3GeV/c$^2$), previously not accessible for other
direct detection experiments.
-
The purpose of this document is to describe the upgrade of the CRESST dark
matter search at LNGS. The proposed strategy will allow to explore a region of
the parameter space for spin-independent WIMP-nucleon elastic scattering
corresponding to WIMP masses below 10GeV/c$^\text{2}$, that has not been
covered by other experiments. These results can be achieved only with
outstanding detector performances in terms of threshold and background. This
proposal shows how CRESST can match these performance requirements, adding a
unique piece of information to the dark matter puzzle. The results of this
program will fix a new state-of-the-art in the low mass WIMP exploration,
opening new perspectives of understanding the dark matter scenario.
-
Atmospheric and solar neutrinos scattering coherently off target nuclei will
be an important background source for the next generation of direct dark matter
searches. In this work we focus on calcium tungstate as target material. For
comparison with existing works we calculate the neutrino floor indicating which
sensitivities can be reached before the neutrino background appears. In
addition, we investigate the sensitivities of future direct dark matter
searches using CRESST-II like detectors. Extending previous works we take into
account achievable energy resolutions and thresholds as well as beta and gamma
backgrounds for this investigation. We show that an exploration of WIMP-nucleon
cross sections below the neutrino floor is possible for exposures of
$\gtrsim10$ kg-years or higher. In the third part we show that a first
detection of coherent neutrino nucleus scattering of atmospheric and solar
neutrinos using the same detectors and the backgrounds is feasible for
exposures of $\gtrsim50$ kg-years.
-
The CRESST-II cryogenic dark matter search aims for the detection of WIMPs
via elastic scattering off nuclei in CaWO$_4$ crystals. We present results from
a low-threshold analysis of a single upgraded detector module. This module
efficiently vetoes low energy backgrounds induced by $\alpha$-decays on inner
surfaces of the detector. With an exposure of \unit[29.35]{kg live days}
collected in 2013 we set a limit on spin-independent WIMP-nucleon scattering
which probes a new region of parameter space for WIMP masses below
\unit[3]{GeV/c$^2$}, previously not covered in direct detection searches. A
possible excess over background discussed for the previous CRESST-II phase 1
(from 2009 to 2011) is not confirmed.
-
We demonstrate that Neganov-Luke amplified cryogenic light detectors with
Transition Edge Sensor read-out can be applied for the background suppression
in cryogenic experiments searching for the neutrinoless double beta decay of
$^{130}\text{Te}$ with TeO$_{2}$ based bolometers. Electron and gamma induced
events can be discriminated from $\alpha$ events by detecting the Cherenkov
light produced by the $\beta$ particles emitted in the decay. We use the
Cherenkov light produced by events in the full energy peak of $^{208}\text{Tl}$
and by events from a $^{147}\text{Sm}$ source to show that at the Q-value of
the neutrinoless double beta decay of $^{130}\text{Te}$ ($Q_{\beta \beta} =
2.53 \,\text{MeV}$), a separation of $e^{-}/\gamma$ events from $\alpha$ events
can be achieved on an event-by-event basis with practically no reduction in
signal acceptance.
-
The direct dark matter search experiment CRESST uses scintillating CaWO$_4$
single crystals as targets for possible WIMP scatterings. An intrinsic
radioactive contamination of the crystals as low as possible is crucial for the
sensitivity of the detectors. In the past CaWO$_4$ crystals operated in CRESST
were produced by institutes in Russia and the Ukraine. Since 2011 CaWO$_4$
crystals have also been grown at the crystal laboratory of the Technische
Universit\"at M\"unchen (TUM) to better meet the requirements of CRESST and of
the future tonne-scale multi-material experiment EURECA. The radiopurity of the
raw materials and of first TUM-grown crystals was measured by ultra-low
background $\gamma$-spectrometry. Two TUM-grown crystals were also operated as
low-temperature detectors at a test setup in the Gran Sasso underground
laboratory. These measurements were used to determine the crystals' intrinsic
$\alpha$-activities which were compared to those of crystals produced at other
institutes. The total $\alpha$-activities of TUM-grown crystals as low as 1.23
$\pm$ 0.06 mBq/kg were found to be significantly smaller than the activities of
crystals grown at other institutes typically ranging between ~15 mBq/kg and ~35
mBq/kg.