-
We present the results of a search for dark matter WIMPs in the mass range
below 20 GeV/c^2 using a target of low-radioactivity argon. The data were
obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso
(LNGS). The analysis is based on the ionization signal, for which the
DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The
observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and
is almost entirely accounted for by known background sources. We obtain a 90%
C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section
of dark matter WIMPs on nucleons, extending the exclusion region for dark
matter below previous limits in the range 1.8-6 GeV/c^2.
-
We present new constraints on sub-GeV dark matter particles scattering off
electrons in argon based on an analysis of ionization signal data from the
DarkSide-50 detector.
-
The DarkSide-50 direct-detection dark matter experiment is a dual-phase argon
time projection chamber operating at Laboratori Nazionali del Gran Sasso. This
paper reports on the blind analysis and spin-independent dark matter-nucleon
coupling results from a 532.4 live-days exposure, using a target of
low-radioactivity argon extracted from underground sources. The background-free
result in the dark matter selection box gave no evidence for dark matter. The
present blind analysis sets a 90% C.L. upper limit on the dark matter-nucleon
spin-independent cross section of 1.1E-44 cm^2 (3.8E-44 cm^2, 3.4E-43 cm^2) for
a WIMP mass of 100 GeV/c^2 (1 TeV/c^2, 10 TeV/c^2).
-
We report the measurement of the longitudinal diffusion constant in liquid
argon with the DarkSide-50 dual-phase time projection chamber. The measurement
is performed at drift electric fields of 100 V/cm, 150 V/cm, and 200 V/cm using
high statistics $^{39}$Ar decays from atmospheric argon. We derive an
expression to describe the pulse shape of the electroluminescence signal (S2)
in dual-phase TPCs. The derived S2 pulse shape is fit to events from the
uppermost portion of the TPC in order to characterize the radial dependence of
the signal. The results are provided as inputs to the measurement of the
longitudinal diffusion constant DL, which we find to be (4.12 $\pm$ 0.04)
cm$^2$/s for a selection of 140keV electron recoil events in 200V/cm drift
field and 2.8kV/cm extraction field. To study the systematics of our
measurement we examine datasets of varying event energy, field strength, and
detector volume yielding a weighted average value for the diffusion constant of
(4.09 $\pm$ 0.09) cm$^2$ /s. The measured longitudinal diffusion constant is
observed to have an energy dependence, and within the studied energy range the
result is systematically lower than other results in the literature.
-
A Geant4-based Monte Carlo package named G4DS has been developed to simulate
the response of DarkSide-50, an experiment operating since 2013 at LNGS,
designed to detect WIMP interactions in liquid argon. In the process of WIMP
searches, DarkSide-50 has achieved two fundamental milestones: the rejection of
electron recoil background with a power of ~10^7, using the pulse shape
discrimination technique, and the measurement of the residual 39Ar
contamination in underground argon, ~3 orders of magnitude lower with respect
to atmospheric argon. These results rely on the accurate simulation of the
detector response to the liquid argon scintillation, its ionization, and
electron-ion recombination processes. This work provides a complete overview of
the DarkSide Monte Carlo and of its performance, with a particular focus on
PARIS, the custom-made liquid argon response model.
-
We report on the cryogenic characterization of Red Green Blue - High Density
(RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the
DarkSide program of dark matter searches with liquid argon time projection
chambers. A dedicated setup was used to measure the primary dark noise, the
correlated noise, and the gain of the SiPMs at varying temperatures. A
custom-made data acquisition system and analysis software were used to
precisely characterize these parameters. We demonstrate that FBK RGB-HD SiPMs
with low quenching resistance (RGB-HD-LR$_q$) can be operated from 40 K to 300
K with gains in the range $10^5$ to $10^6$ and noise rates on the order of a
few Hz/mm$^2$.
-
The axio-electric effect in silicon atoms is sought for solar axions
appearing owing to bremsstrahlung and the Compton process. Axions are detected
using a Si(Li) detector placed in a low-background setup. As a result, a
model-independent constraint on the axion-electron coupling constant $|g_{Ae}|
\leq 2.2\times 10^{-10}$ has been obtained, which leads to the bounds
$m_{A}\leq$ 7.9 eV and $m_{A}\leq$ 1.4 keV for the mass of the axion in the
DFSZ and KSVZ models, respectively (90% C.L.).
-
The International Axion Observatory (IAXO) is a next generation axion
helioscope aiming at a sensitivity to the axion-photon coupling of a few
10^{-12} GeV^{-1}, i.e. 1-1.5 orders of magnitude beyond sensitivities achieved
by the currently most sensitive axion helioscope, the CERN Axion Solar
Telescope (CAST). Crucial factors in improving the sensitivity for IAXO are the
increase of the magnetic field volume together with the extensive use of x-ray
focusing optics and low background detectors, innovations already successfully
tested at CAST. Electron-coupled axions invoked to explain the white dwarf
cooling, relic axions, and a large variety of more generic axion-like particles
(ALPs) along with other novel excitations at the low-energy frontier of
elementary particle physics could provide additional physics motivation for
IAXO.
-
This white paper addresses the hypothesis of light sterile neutrinos based on
recent anomalies observed in neutrino experiments and the latest astrophysical
data.
-
A project of search for oscillations of reactor neutrinos on a short, 5 - 15
meters, baseline with liquid scintillation position-sensitive detector POSEIDON
is described. The oscillations of the electron antineutrinos into sterile
neutrinos will be searched at 100 MW research reactor with the size of the
active zone of about 0.5 m. The values of the oscillation parameters available
for research are in the region $\delta m^2 = (0.3 - 6) \rm{eV}^2$ and
$\rm{Sin}^2(2\theta)\geq 0.01$.