-
The \MJ\ Collaboration is operating an array of high purity Ge detectors to
search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\
comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between
two modules contained in a low background shield at the Sanford Underground
Research Facility in Lead, South Dakota. Here we present results from data
taken during construction, commissioning, and the start of full operations. We
achieve unprecedented energy resolution of 2.5 keV FWHM at \qval\ and a very
low background with no observed candidate events in 10 kg yr of enriched Ge
exposure, resulting in a lower limit on the half-life of $1.9\times10^{25}$ yr
(90\% CL). This result constrains the effective Majorana neutrino mass to below
240 to 520 meV, depending on the matrix elements used. In our experimental
configuration with the lowest background, the background is $4.0_{-2.5}^{+3.1}$
counts/(FWHM t yr).
-
The MAJORANA Collaboration is searching for the neutrinoless double-beta
decay of the nucleus Ge-76. The MAJORANA DEMONSTRATOR is an array of germanium
detectors deployed with the aim of implementing background reduction techniques
suitable for a tonne scale Ge-76-based search (the LEGEND collaboration). In
the DEMONSTRATOR, germanium detectors operate in an ultra-pure vacuum cryostat
at 80 K. One special challenge of an ultra-pure environment is to develop
reliable cables, connectors, and electronics that do not significantly
contribute to the radioactive background of the experiment. This paper
highlights the experimental requirements and how these requirements were met
for the MAJORANA DEMONSTRATOR, including plans to upgrade the wiring for higher
reliability in the summer of 2018. Also described are requirements for LEGEND
R&D efforts underway to meet these additional requirements.
-
The MAJORANA DEMONSTRATOR is a neutrinoless double beta decay experiment
utilizing enriched Ge-76 detectors in 2 separate modules inside of a common
solid shield at the Sanford Underground Research Facility. The DEMONSTRATOR has
utilized world leading assay sensitivities to develop clean materials and
processes for producing ultra-pure copper and plastic components. This
experiment is now operating, and initial data provide new insights into the
success of cleaning and processing. Post production copper assays after the
completion of Module 1 showed an increase in U and Th contamination in finished
parts compared to starting bulk material. A revised cleaning method and
additional round of surface contamination studies prior to Module 2
construction have provided evidence that more rigorous process control can
reduce surface contamination. This article describes the assay results and
discuss further studies to take advantage of assay capabilities for the purpose
of maintaining ultra clean fabrication and process design.
-
Neutrinoless double-beta decay searches play a major role in determining the
nature of neutrinos, the existence of a lepton violating process, and the
effective Majorana neutrino mass. The MAJORANA Collaboration assembled an array
of high purity Ge detectors to search for neutrinoless double-beta decay in
Ge-76. The MAJORANA DEMONSTRATOR is comprised of 44.1 kg (29.7 kg enriched in
Ge-76) of Ge detectors divided between two modules contained in a
low-background shield at the Sanford Underground Research Facility in Lead,
South Dakota, USA. The initial goals of the DEMONSTRATOR are to establish the
required background and scalability of a Ge-based next-generation ton-scale
experiment. Following a commissioning run that started in 2015, the first
detector module started low-background data production in early 2016. The
second detector module was added in August 2016 to begin operation of the
entire array. We discuss results of the initial physics runs, as well as the
status and physics reach of the full MAJORANA DEMONSTRATOR experiment.
-
The MAJORANA DEMONSTRATOR is an array of point-contact Ge detectors
fabricated from Ge isotopically enriched to 88% in Ge-76 to search for
neutrinoless double beta decay. The processing of Ge for germanium detectors is
a well-known technology. However, because of the high cost of Ge enriched in
Ge-76, special procedures were required to maximize the yield of detector mass
and to minimize exposure to cosmic rays. These procedures include careful
accounting for the material; shielding it to reduce cosmogenic generation of
radioactive isotopes; and development of special reprocessing techniques for
contaminated solid germanium, shavings, grindings, acid etchant and cutting
fluids from detector fabrication. Processing procedures were developed that
resulted in a total yield in detector mass of 70%. However, none of the
acid-etch solution and only 50% of the cutting fluids from detector fabrication
were reprocessed. Had they been processed, the projections for the recovery
yield would be between 80 -- 85%. Maximizing yield is critical to justify a
possible future ton-scale experiment. A process for recovery of germanium from
the acid-etch solution was developed with yield of about 90%. All material was
shielded or stored underground whenever possible to minimize the formation of
Ge-68 by cosmic rays, which contributes background in the double-beta decay
region of interest and cannot be removed by zone refinement and crystal growth.
Formation of Ge-68 was reduced by a significant factor over that in natural
abundance detectors not protected from cosmic rays.
-
We present new limits on exotic keV-scale physics based on 478 kg d of
MAJORANA DEMONSTRATOR commissioning data. Constraints at the 90% confidence
level are derived on bosonic dark matter (DM) and solar axion couplings, Pauli
exclusion principle violating (PEPV) decay, and electron decay using
monoenergetic peak signal-limits above our background. Our most stringent DM
constraints are set for 11.8 keV mass particles, limiting $g_{Ae} <4.5\times
10^{-13}$ for pseudoscalars and $\frac{\alpha'}{\alpha} < 9.7\times 10^{-28}$
for vectors. We also report a 14.4 keV solar axion coupling limit of
$g_{AN}^{\mathrm{eff}}\times g_{Ae}~<~3.8 \times 10^{-17}$, a
$\frac{1}{2}\beta^2~<~8.5\times10^{-48}$ limit on the strength of PEPV electron
transitions, and a lower limit on the electron lifetime of $\tau_e > 1.2 \times
10^{24}\;$yr for $e^- \rightarrow$ invisible.
-
The MAJORANA Collaboration is searching for the neutrinoless double-beta
decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of
germanium detectors deployed with the aim of implementing background reduction
techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra
low-background conditions require regular calibrations to verify proper
function of the detectors. Radioactive line sources can be deployed around the
cryostats containing the detectors for regular energy calibrations. When
measuring in low-background mode, these line sources have to be stored outside
the shielding so they do not contribute to the background. The deployment and
the retraction of the source are designed to be controlled by the data
acquisition system and do not require any direct human interaction. In this
paper, we detail the design requirements and implementation of the calibration
apparatus, which provides the event rates needed to define the pulse-shape cuts
and energy calibration used in the final analysis as well as data that can be
compared to simulations.
-
The Majorana Demonstrator searches for neutrinoless double-beta decay of
$^{76}$Ge using arrays of high-purity germanium detectors. If observed, this
process would demonstrate that lepton number is not a conserved quantity in
nature, with implications for grand-unification and for explaining the
predominance of matter over antimatter in the universe. A problematic
background in such large granular detector arrays is posed by alpha particles.
In the Majorana Demonstrator, events have been observed that are consistent
with energy- degraded alphas originating on the passivated surface, leading to
a potential background contribution in the region-of-interest for neutrinoless
double-beta decay. However, it is also observed that when energy deposition
occurs very close to the passivated surface, charges drift through the bulk
onto that surface, and then drift along it with greatly reduced mobility. This
leads to both a reduced prompt signal and a measurable change in slope of the
tail of a recorded pulse. In this contribution we discuss the characteristics
of these events and the development of a filter that can identify the
occurrence of this delayed charge recovery, allowing for the efficient
rejection of passivated surface alpha events in analysis.
-
Neutrinoless double-beta decay searches seek to determine the nature of
neutrinos, the existence of a lepton violating process, and the effective
Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array
of high purity Ge detectors to search for neutrinoless double-beta decay in
$^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg
enriched in $^{76}$Ge) of Ge detectors in total, split between two modules
contained in a low background shield at the Sanford Underground Research
Facility in Lead, South Dakota. The initial goals of the {\sc Demonstrator} are
to establish the required background and scalability of a Ge-based,
next-generation, tonne-scale experiment. Following a commissioning run that
began in 2015, the first detector module started physics data production in
early 2016. We will discuss initial results of the Module 1 commissioning and
first physics run, as well as the status and potential physics reach of the
full {\sc Majorana Demonstrator} experiment. The collaboration plans to
complete the assembly of the second detector module by mid-2016 to begin full
data production with the entire array.
-
The MAJORANA Collaboration is constructing a system containing 44 kg of
high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of
a future tonne-scale experiment capable of probing the neutrino mass scale to
~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to
demonstrate a path forward to achieving a background rate at or below 1
count/(ROI-t-y) in the 4 keV region of interest (ROI) around the Q-value at
2039 keV. This goal is pursued through a combination of a significant reduction
of radioactive impurities in construction materials and analytical methods for
background rejection, for example using powerful pulse shape analysis
techniques profiting from the p-type point contact HPGe detectors technology.
The effectiveness of these methods is assessed using simulations of the
different background components whose purity levels are constrained from
radioassay measurements. Preliminary background results obtained during the
engineering runs of the Demonstrator are presented.
-
We report the first measurement of the total MUON flux underground at the
Davis Campus of the Sanford Underground Research Facility at the 4850 ft level.
Measurements were done with the Majorana Demonstrator veto system arranged in
two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9
muons/s/cm^2.
-
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an
ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7
kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in
Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta
decay searches will probe the neutrino mass scale in the inverted-hierarchy
region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward
to achieve a background rate at or below 1 count/tonne/year in the 4 keV region
of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a
modular implementation to be easily scalable to the next generation experiment.
First data taken with the DEMONSTRATOR are introduced here.
-
We prove that every $C^1$ three-dimensional flow with positive topological
entropy can be $C^1$ approximated by flows with homoclinic orbits. This extends
a previous result for $C^1$ surface diffeomorphisms \cite{g}.
-
We prove that every sectional Anosov flow (or, equivalently, every
sectional-hyperbolic attracting set of a flow) on a compact manifold has a
periodic orbit. This extends the previous three-dimensional result obtained in
[Existence of periodic orbits for singular-hyperbolic sets].
-
A sectional-Anosov flow on a manifold M is a C^1 vector field inwardly
transverse to the boundary for which the maximal invariant is
sectional-hyperbolic. We prove that every attractor of every vector field C^1
close to a transitive sectional-Anosov flow with singularities on a compact
manifold has a singularity. This extends the three-dimensional result obtained
in [Morales, C.A., The explosion of singular-hyperbolic attractors].