The next-generation Enriched Xenon Observatory (nEXO) is a proposed
experiment to search for neutrinoless double beta ($0\nu\beta\beta$) decay in
$^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years
using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time
projection chamber. This improvement of two orders of magnitude in sensitivity
over current limits is obtained by a significant increase of the $^{136}$Xe
mass, the monolithic and homogeneous configuration of the active medium, and
the multi-parameter measurements of the interactions enabled by the time
projection chamber. The detector concept and anticipated performance are
presented based upon demonstrated realizable background rates.
-
We apply deep neural networks (DNN) to data from the EXO-200 experiment. In
the studied cases, the DNN is able to reconstruct the relevant parameters -
total energy and position - directly from raw digitized waveforms, with minimal
exceptions. The accuracy of reconstruction, as evaluated on calibration data,
either reaches or exceeds what was achieved by the conventional approaches
developed by EXO-200 over the course of the experiment. An accurate Monte Carlo
simulation is usually a prerequisite for a successful reconstruction with DNNs.
We describe how in an experiment such as EXO-200 certain reconstruction and
analysis tasks could be successfully performed by training the network on
waveforms from experimental data, either reducing or eliminating the reliance
on the Monte Carlo.
-
A search for instability of nucleons bound in $^{136}$Xe nuclei is reported
with 223 kg$\cdot$yr exposure of $^{136}$Xe in the EXO-200 experiment. Lifetime
limits of 3.3$\times 10^{23}$ and 1.9$\times 10^{23}$ yrs are established for
nucleon decay to $^{133}$Sb and $^{133}$Te, respectively. These are the most
stringent to date, exceeding the prior decay limits by a factor of 9 and 7,
respectively.
-
Results from a search for neutrinoless double-beta decay $0\nu\beta\beta$ of
$^{136}$Xe are presented using the first year of data taken with the upgraded
EXO-200 detector. Relative to previous searches by EXO-200, the energy
resolution of the detector has been improved to $\sigma/E$=1.23%, the electric
field in the drift region has been raised by 50%, and a system to suppress
radon in the volume between the cryostat and lead shielding has been
implemented. In addition, analysis techniques that improve topological
discrimination between $0\nu\beta\beta$ and background events have been
developed. Incorporating these hardware and analysis improvements, the median
90% confidence level $0\nu\beta\beta$ half-life sensitivity after combining
with the full data set acquired before the upgrade has increased 2-fold to $3.7
\times 10^{25}$ yr. No statistically significant evidence for $0\nu\beta\beta$
is observed, leading to a lower limit on the $0\nu\beta\beta$ half-life of
$1.8\times10^{25}$ yr at the 90% confidence level.
-
A new design for the anode of a time projection chamber, consisting of a
charge-detecting "tile", is investigated for use in large scale liquid xenon
detectors. The tile is produced by depositing 60 orthogonal metal
charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm}
fused-silica wafer. These charge tiles may be employed by large detectors, such
as the proposed tonne-scale nEXO experiment to search for neutrinoless
double-beta decay. Modular by design, an array of tiles can cover a sizable
area. The width of each strip is small compared to the size of the tile, so a
Frisch grid is not required. A grid-less, tiled anode design is beneficial for
an experiment such as nEXO, where a wire tensioning support structure and
Frisch grid might contribute radioactive backgrounds and would have to be
designed to accommodate cycling to cryogenic temperatures. The segmented anode
also reduces some degeneracies in signal reconstruction that arise in
large-area crossed-wire time projection chambers. A prototype tile was tested
in a cell containing liquid xenon. Very good agreement is achieved between the
measured ionization spectrum of a $^{207}$Bi source and simulations that
include the microphysics of recombination in xenon and a detailed modeling of
the electrostatic field of the detector. An energy resolution $\sigma/E$=5.5\%
is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only
resolution reported in literature for liquid xenon at 936~V/\si{cm}.
-
Searches for double beta decay of $^{134}\text{Xe}$ were performed with
EXO-200, a single-phase liquid xenon detector designed to search for
neutrinoless double beta decay of $^{136}\text{Xe}$. Using an exposure of
$29.6\text{ kg}\!\cdot\!\text{yr}$, the lower limits of
$\text{T}_{1/2}^{2\nu\beta\!\beta}>8.7\cdot10^{20}\text{ yr}$ and
$\text{T}_{1/2}^{0\nu\beta\!\beta}>1.1\cdot10^{23}\text{ yr}$ at 90\%
confidence level were derived, with corresponding half-life sensitivities of
$1.2\cdot10^{21}\text{ yr}$ and $1.9\cdot10^{23}\text{ yr}$. These limits
exceed those in the literature for $^{134}\text{Xe}$, improving by factors of
nearly $10^{5}$ and 2 for the two antineutrino and neutrinoless modes,
respectively.
-
Alpha decays in the EXO-200 detector are used to measure the fraction of
charged $^{218}\mathrm{Po}$ and $^{214}\mathrm{Bi}$ daughters created from
alpha and beta decays, respectively. $^{222}\mathrm{Rn}$ alpha decays in liquid
xenon (LXe) are found to produce $^{218}\mathrm{Po}^{+}$ ions $50.3 \pm 3.0\%$
of the time, while the remainder of the $^{218}\mathrm{Po}$ atoms are neutral.
The fraction of $^{214}\mathrm{Bi}^{+}$ from $^{214}\mathrm{Pb}$ beta decays in
LXe is found to be $76.4 \pm 5.7\%$, inferred from the relative rates of
$^{218}\mathrm{Po}$ and $^{214}\mathrm{Po}$ alpha decays in the LXe. The
average velocity of $^{218}\mathrm{Po}$ ions is observed to decrease for longer
drift times. Initially the ions have a mobility of $0.390 \pm
0.006~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$, and at long drift times the
mobility is $0.219 \pm 0.004~\mathrm{cm}^2/(\mathrm{kV}~\mathrm{s})$. Time
constants associated with the change in mobility during drift of the
$^{218}\mathrm{Po}^{+}$ ions are found to be proportional to the electron
lifetime in the LXe.
-
We report results from a systematic measurement campaign conducted to
identify low radioactivity materials for the construction of the EXO-200 double
beta decay experiment. Partial results from this campaign have already been
reported in a 2008 paper by the EXO collaboration. Here we release the
remaining data, collected since 2007, to the public. The data reported were
obtained using a variety of analytic techniques. The measurement sensitivities
are among the best in the field. Construction of the EXO-200 detector has been
concluded, and Phase-I data was taken from 2011 to 2014. The detector's
extremely low background implicitly verifies the measurements and the analysis
assumptions made during construction and reported in this paper.
-
The EXO-200 Collaboration is searching for neutrinoless double beta decay
using a liquid xenon (LXe) time projection chamber. This measurement relies on
modeling the transport of charge deposits produced by interactions in the LXe
to allow discrimination between signal and background events. Here we present
measurements of the transverse diffusion constant and drift velocity of
electrons at drift fields between 20~V/cm and 615~V/cm using EXO-200 data. At
the operating field of 380~V/cm EXO-200 measures a drift velocity of
1.705$_{-0.010}^{+0.014}$~mm/$\mu$s and a transverse diffusion coefficient of
55$\pm$4~cm$^2$/s.
-
The energy resolution of the EXO-200 detector is limited by electronics noise
in the measurement of the scintillation response. Here we present a new
technique to extract optimal scintillation energy measurements for signals
split across multiple channels in the presence of correlated noise. The
implementation of these techniques improves the energy resolution of the
detector at the neutrinoless double beta decay Q-value from $\left[1.9641\pm
0.0039\right]\%$ to $\left[1.5820\pm 0.0044\right]\%$.
-
EXO-200 is a single phase liquid xenon detector designed to search for
neutrinoless double-beta decay of $^{136}$Xe to the ground state of $^{136}$Ba.
We report here on a search for the two-neutrino double-beta decay of $^{136}$Xe
to the first $0^+$ excited state, $0^+_1$, of $^{136}$Ba based on a 100
kg$\cdot$yr exposure of $^{136}$Xe. Using a specialized analysis employing a
machine learning algorithm, we obtain a 90% CL half-life sensitivity of $1.7
\times 10^{24}$ yr. We find no statistically significant evidence for the
$2\nu\beta\beta$ decay to the excited state resulting in a lower limit of
$T^{2\nu}_{1/2}$ ($0^+ \rightarrow 0^+_1$) $> 6.9 \times 10^{23}$ yr at 90% CL.
This observed limit is consistent with the estimated half-life of
$2.5\times10^{25}$ yr.
-
We describe a system to transport and identify barium ions produced in liquid
xenon, as part of R&D towards the second phase of a double beta decay
experiment, nEXO. The goal is to identify the Ba ion resulting from an
extremely rare nuclear decay of the isotope $^{136}$Xe, hence providing a
confirmation of the occurrence of the decay. This is achieved through Resonance
Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be
produced in liquid xenon or vacuum and collected on a clean substrate. This
substrate is then removed to an analysis chamber under vacuum, where
laser-induced thermal desorption and RIS are used with time-of-flight (TOF)
mass spectroscopy for positive identification of the barium decay product.
-
As neutrinoless double-beta decay experiments become more sensitive and
intrinsic radioactivity in detector materials is reduced, previously minor
contributions to the background must be understood and eliminated. With this in
mind, cosmogenic backgrounds have been studied with the EXO-200 experiment.
Using the EXO-200 TPC, the muon flux (through a flat horizontal surface)
underground at the Waste Isolation Pilot Plant (WIPP) has been measured to be
{\Phi} = 4.07 $\pm$ 0.14 (sys) $\pm$ 0.03 (stat) $\times$ $10^{-7}$cm$^{-2}$
s$^{-1}$, with a vertical intensity of $I_{v}$ = 2.97$^{+0.14}_{-0.13}$ (sys)
$\pm$ 0.02 (stat) $\times$ $10^{-7}$cm$^{-2}$ s$^{-1}$ sr$^{-1}$. Simulations
of muon-induced backgrounds identified several potential cosmogenic
radionuclides, though only 137Xe is a significant background for the 136Xe
0{\nu}{\beta}{\beta} search with EXO-200. Muon-induced neutron backgrounds were
measured using {\gamma}-rays from neutron capture on the detector materials.
This provided a measurement of 137Xe yield, and a test of the accuracy of the
neutron production and transport simulations. The independently measured rates
of 136Xe neutron capture and of 137Xe decay agree within uncertainties. Geant4
and FLUKA simulations were performed to estimate neutron capture rates, and
these estimates agreed to within ~40% or better with measurements. The ability
to identify 136Xe(n,{\gamma}) events will allow for rejection of 137Xe
backgrounds in future 0{\nu}{\beta}{\beta} analyses.
-
A search for Lorentz- and CPT-violating signals in the double beta decay
spectrum of $^{136}$Xe has been performed using an exposure of 100 kg$\cdot$yr
with the EXO-200 detector. No significant evidence of the spectral modification
due to isotropic Lorentz-violation was found, and a two-sided limit of $-2.65
\times 10^{-5 } \; \textrm{GeV} < \mathring{a}^{(3)}_{\text{of}} < 7.60 \times
10^{-6} \; \textrm{GeV}$ (90% C.L.) is placed on the relevant coefficient
within the Standard-Model Extension (SME). This is the first experimental study
of the effect of the SME-defined oscillation-free and momentum-independent
neutrino coupling operator on the double beta decay process.
-
The search for neutrinoless double-beta decay (0{\nu}{\beta}{\beta}) requires
extremely low background and a good understanding of their sources and their
influence on the rate in the region of parameter space relevant to the
0{\nu}{\beta}{\beta} signal. We report on studies of various {\beta}- and
{\gamma}-backgrounds in the liquid- xenon-based EXO-200 0{\nu}{\beta}{\beta}
experiment. With this work we try to better understand the location and
strength of specific background sources and compare the conclusions to
radioassay results taken before and during detector construction. Finally, we
discuss the implications of these studies for EXO-200 as well as for the
next-generation, tonne-scale nEXO detector.
-
Many current and future dark matter and neutrino detectors are designed to
measure scintillation light with a large array of photomultiplier tubes (PMTs).
The energy resolution and particle identification capabilities of these
detectors depend in part on the ability to accurately identify individual
photoelectrons in PMT waveforms despite large variability in pulse amplitudes
and pulse pileup. We describe a Bayesian technique that can identify the times
of individual photoelectrons in a sampled PMT waveform without deconvolution,
even when pileup is present. To demonstrate the technique, we apply it to the
general problem of particle identification in single-phase liquid argon dark
matter detectors. Using the output of the Bayesian photoelectron counting
algorithm described in this paper, we construct several test statistics for
rejection of backgrounds for dark matter searches in argon. Compared to simpler
methods based on either observed charge or peak finding, the photoelectron
counting technique improves both energy resolution and particle identification
of low energy events in calibration data from the DEAP-1 detector and
simulation of the larger MiniCLEAN dark matter detector.
-
EXO-200 is a single phase liquid xenon detector designed to search for
neutrinoless double-beta decay of $^{136}$Xe. Here we report on a search for
various Majoron-emitting modes based on 100 kg$\cdot$yr exposure of $^{136}$Xe.
A lower limit of $T^{^{136}Xe}_{1/2} >1.2 \cdot 10^{24}$ yr at 90% C.L. on the
half-life of the spectral index = 1 Majoron decay was obtained, corresponding
to a constraint on the Majoron-neutrino coupling constant of $|< g^{M}_{ee}
>|<$ (0.8-1.7)$\cdot$10$^{-5}$.
-
Progress on a method of barium tagging for the nEXO double beta decay
experiment is reported. Absorption and emission spectra for deposits of barium
atoms and ions in solid xenon matrices are presented. Excitation spectra for
prominent emission lines, temperature dependence and bleaching of the
fluorescence reveal the existence of different matrix sites. A regular series
of sharp lines observed in Ba$^+$ deposits is identified with some type of
barium hydride molecule. Lower limits for the fluorescence quantum efficiency
of the principal Ba emission transition are reported. Under current conditions,
an image of $\le10^4$ Ba atoms can be obtained. Prospects for imaging single Ba
atoms in solid xenon are discussed.
-
Many extensions of the Standard Model of particle physics suggest that
neutrinos should be Majorana-type fermions, but this assumption is difficult to
confirm. Observation of neutrinoless double-beta decay ($0\nu \beta \beta$), a
spontaneous transition that may occur in several candidate nuclei, would verify
the Majorana nature of the neutrino and constrain the absolute scale of the
neutrino mass spectrum. Recent searches carried out with $^{76}$Ge (GERDA
experiment) and $^{136}$Xe (KamLAND-Zen and EXO-200 experiments) have
established the lifetime of this decay to be longer than $10^{25}$ yr,
corresponding to a limit on the neutrino mass of 0.2-0.4 eV. Here we report new
results from EXO-200 based on 100 kg$\cdot$yr of $^{136}$Xe exposure,
representing an almost fourfold increase from our earlier published datasets.
We have improved the detector resolution at the $^{136}$Xe double-beta-decay
Q-value to $\sigma$/E = 1.53% and revised the data analysis. The obtained
half-life sensitivity is $1.9\cdot10^{25}$ yr, an improvement by a factor of
2.7 compared to previous EXO-200 results. We find no statistically significant
evidence for $0\nu \beta \beta$ decay and set a half-life limit of
$1.1\cdot10^{25}$ yr at 90% CL. The high sensitivity holds promise for further
running of the EXO-200 detector and future $0\nu \beta \beta$ decay searches
with nEXO.
-
We report on an improved measurement of the 2\nu \beta \beta\ half-life of
Xe-136 performed by EXO-200. The use of a large and homogeneous time projection
chamber allows for the precise estimate of the fiducial mass used for the
measurement, resulting in a small systematic uncertainty. We also discuss in
detail the data analysis methods used for double-beta decay searches with
EXO-200, while emphasizing those directly related to the present measurement.
The Xe-136 2\nu \beta \beta\ half-life is found to be 2.165 +- 0.016 (stat) +-
0.059 (sys) x 10^21 years. This is the most precisely measured half-life of any
2\nu \beta \beta\ decay to date.
-
We report on a search for neutrinoless double-beta decay of $^{136}$Xe with
EXO-200. No signal is observed for an exposure of 32.5 kg-yr, with a background
of ~1.5 x 10^{-3} /(kg yr keV) in the $\pm 1\sigma$ region of interest. This
sets a lower limit on the half-life of the neutrinoless double-beta decay
$T_{1/2}^{0\nu\beta\beta}$($^{136}$Xe) > 1.6 x 10$^{25}$ yr (90% CL),
corresponding to effective Majorana masses of less than 140-380 meV, depending
on the matrix element calculation.
-
EXO-200 is an experiment designed to search for double beta decay of
$^{136}$Xe with a single-phase, liquid xenon detector. It uses an active mass
of 110 kg of xenon enriched to 80.6% in the isotope 136 in an ultra-low
background time projection chamber capable of simultaneous detection of
ionization and scintillation. This paper describes the EXO-200 detector with
particular attention to the most innovative aspects of the design that revolve
around the reduction of backgrounds, the efficient use of the expensive
isotopically enriched xenon, and the optimization of the energy resolution in a
relatively large volume.
-
We report the observation of two-neutrino double-beta decay in Xe-136 with
T_1/2 = 2.11 +- 0.04 (stat.) +- 0.21 (sys.) x 10^21 yr. This second order
process, predicted by the Standard Model, has been observed for several nuclei
but not for Xe-136. The observed decay rate provides new input to matrix
element calculations and to the search for the more interesting neutrino-less
double-beta decay, the most sensitive probe for the existence of Majorana
particles and the measurement of the neutrino mass scale.
-
We describe purity measurements of the natural and enriched xenon stockpiles
used by the EXO-200 double beta decay experiment based on a mass spectrometry
technique. The sensitivity of the spectrometer is enhanced by several orders of
magnitude by the presence of a liquid nitrogen cold trap, and many impurity
species of interest can be detected at the level of one part-per-billion or
better. We have used the technique to screen the EXO-200 xenon before, during,
and after its use in our detector, and these measurements have proven useful.
This is the first application of the cold trap mass spectrometry technique to
an operating physics experiment.
-
A magnetically driven piston pump for xenon gas recirculation is presented.
The pump is designed to satisfy extreme purity and containment requirements, as
is appropriate for the recirculation of isotopically enriched xenon through the
purification system and large liquid xenon TPC of EXO-200. The pump, using
sprung polymer gaskets, is capable of pumping more than 16 standard liters per
minute (SLPM) of xenon gas with 750 torr differential pressure.