The CUORE experiment, a ton-scale cryogenic bolometer array, recently began
operation at the Laboratori Nazionali del Gran Sasso in Italy. The array
represents a significant advancement in this technology, and in this work we
apply it for the first time to a high-sensitivity search for a
lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay.
Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an
effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the
region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we
find no evidence for neutrinoless double-beta decay. The median statistical
sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic
uncertainties, we place a lower limit on the decay half-life of
$T^{0\nu}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining
this result with those of two earlier experiments, Cuoricino and CUORE-0, we
find $T^{0\nu}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is
the most stringent limit to date on this decay. Interpreting this result as a
limit on the effective Majorana neutrino mass, we find $m_{\beta\beta}<(110 -
520)$ meV, where the range reflects the nuclear matrix element estimates
employed.
-
The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso,
Italy, is the first large array of enriched scintillating cryogenic detectors
for the investigation of $^{82}$Se neutrinoless double-beta decay
(0$\nu\beta\beta$). CUPID-0 aims at measuring a background index in the region
of interest (RoI) for 0$\nu\beta\beta$ at the level of 10$^{-3}$ c/keV/kg/y,
the lowest value ever measured using cryogenic detectors. This result can be
achieved by a state of the art technology for background suppression and
thorough protocols and procedures for detector preparation and construction. In
this paper, the different phases of the detector design and construction will
be presented, from the material selection (for the absorber production) to the
new and innovative detector structure. The successful construction of the
detector lead to promising detector performance which are here preliminarily
discussed
-
We report the result of the search for neutrinoless double beta decay of
$^{82}$Se obtained with CUPID-0, the first large array of scintillating
Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We
observe no signal in a 1.83 kg$\cdot$yr $^{82}$Se exposure and we set the most
stringent lower limit on the \onu $^{82}$Se half-life T$^{0\nu}_{1/2}>$
2.4$\cdot \mathrm{10}^{24}$ yr (90\% C.I.), which corresponds to an effective
Majorana neutrino mass m$_{\beta\beta} <$ (376-770) meV depending on the
nuclear matrix element calculations. The heat-light readout provides a powerful
tool for the rejection of \al\ particles and allows to suppress the background
in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$\cdot$10$^{-3}$\ckky,
an unprecedented level for this technique.
-
CUORE - the Cryogenic Underground Observatory for Rare Events - is an
experiment searching for the neutrinoless double-beta ($0\nu\beta\beta$) decay
of $^{130}$Te with an array of 988 TeO$_2$ crystals operated as bolometers at
$\sim$10 mK in a large dilution refrigerator. With this detector, we aim for a
$^{130}$Te $0\nu\beta\beta$ decay half-life sensitivity of $9\times10^{25}$ y
with 5 y of live time, and a background index of $\lesssim 10^{-2}$
counts/keV/kg/y. Making an effort to maintain radiopurity by minimizing the
bolometers' exposure to radon gas during their installation in the cryostat, we
perform all operations inside a dedicated cleanroom environment with a
controlled radon-reduced atmosphere. In this paper, we discuss the design and
performance of the CUORE Radon Abatement System and cleanroom, as well as a
system to monitor the radon level in real time.
-
TeO2 bolometers have been used for many years to search for neutrinoless
double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently
published the most sensitive limit on the half-life, $T_{1/2}^{0\nu} > 1.5
\times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on
the effective Majorana mass of the neutrino. While it makes CUORE a
world-leading experiment looking for neutrinoless double beta decay, it is not
the only study that CUORE will contribute to in the field of nuclear and
particle physics. As already done over the years with many small-scale
experiments, CUORE will investigate both rare decays (such as the two-neutrino
double beta decay of 130-Te and the hypothesized electron capture in 123-Te),
and rare processes (e.g., dark matter and axion interactions). This paper
describes some of the achievements of past experiments that used TeO2
bolometers, and perspectives for CUORE.
-
We have performed a search for neutrinoless $\beta^{+}\hspace{-0.2em}EC$
decay of $^{120}$Te using the final CUORE-0 data release. We describe a new
analysis method for the simultaneous fit of signatures with different event
topology, and of data subsets with different signal efficiency, obtaining a
limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$
CI. Combining this with results from Cuoricino, a predecessor experiment, we
obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$
yr at $90\%$ CI.
-
The paper describes the Faraday room that shields the CUORE experiment
against electromagnetic fields, from 50 Hz up to high frequency. Practical
contraints led to choose panels made of light shielding materials. The seams
between panels were optimized with simulations to minimize leakage.
Measurements of shielding performance show attenuation of a factor 15 at 50 Hz,
and a factor 1000 above 1 KHz up to about 100 MHz.
-
Models for light dark matter particles with masses below 1 GeV/c$^2$ are a
natural and well-motivated alternative to so-far unobserved weakly interacting
massive particles. Gram-scale cryogenic calorimeters provide the required
detector performance to detect these particles and extend the direct dark
matter search program of CRESST. A prototype 0.5 g sapphire detector developed
for the $\nu$-cleus experiment has achieved an energy threshold of
$E_{th}=(19.7\pm 0.9)$ eV, which is one order of magnitude lower than previous
results and independent of the type of particle interaction. The result
presented here is obtained in a setup above ground without significant
shielding against ambient and cosmogenic radiation. Although operated in a
high-background environment, the detector probes a new range of light-mass dark
matter particles previously not accessible by direct searches. We report the
first limit on the spin-independent dark matter particle-nucleon cross section
for masses between 140 MeV/c$^2$ and 500 MeV/c$^2$.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to
search for neutrinoless double beta decay of 130Te with an array of 988 TeO2
bolometers operating at temperatures around 10 mK. The experiment is currently
being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The
goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay
half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main
issue to be addressed to accomplish this aim is the rate of background events
in the region of interest, which must not be higher than
10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation,
based on results from a campaign of material screening, radioassays, and
bolometric measurements, to evaluate the expected background. This was used
over the years to guide the construction strategies of the experiment and we
use it here to project a background model for CUORE. In this paper we report
the results of our study and our expectations for the background rate in the
energy region where the peak signature of neutrinoless double beta decay of
130Te is expected.
-
CUORE is a tonne-scale cryogenic detector operating at the Laboratori
Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to
search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable
to search for low energy rare events such as solar axions or WIMP scattering,
thanks to its ultra-low background and large target mass. However, to conduct
such sensitive searches requires improving the energy threshold to 10 keV. In
this paper, we describe the analysis techniques developed for the low energy
analysis of CUORE-like detectors, using the data acquired from November 2013 to
March 2015 by CUORE-0, a single-tower prototype designed to validate the
assembly procedure and new cleaning techniques of CUORE. We explain the energy
threshold optimization, continuous monitoring of the trigger efficiency, data
and event selection, and energy calibration at low energies in detail. We also
present the low energy background spectrum of CUORE-0 below 60keV. Finally, we
report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0
energy threshold and background, as well as an estimate of the uncertainty on
the nuclear quenching factor from nuclear recoils in CUORE-0.
-
In Phase 2 of CRESST-II 18 detector modules were operated for about two years
(July 2013 - August 2015). Together with this document we are publishing data
from two detector modules which have been used for direct dark-matter searches.
With these data-sets we were able to set world-leading limits on the cross
section for spin-independent elastic scattering of dark matter particles off
nuclei. We publish the energies of all events within the acceptance regions for
dark-matter searches. In addition, we also publish the energies of the events
within the electron-recoil band. This data set can be used to study
interactions with electrons of CaWO$_4$. In this document we describe how to
use these data sets. In particular, we explain the cut-survival probabilities
required for comparisons of models with the data sets.
-
We report a study of the CUORE sensitivity to neutrinoless double beta
($0\nu\beta\beta$) decay. We used a Bayesian analysis based on a toy Monte
Carlo (MC) approach to extract the exclusion sensitivity to the
$0\nu\beta\beta$ decay half-life ($T_{1/2}^{0\nu}$) at $90\%$ credibility
interval (CI) -- i.e. the interval containing the true value of
$T_{1/2}^{0\nu}$ with $90\%$ probability -- and the $3 \sigma$ discovery
sensitivity. We consider various background levels and energy resolutions, and
describe the influence of the data division in subsets with different
background levels. If the background level and the energy resolution meet the
expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of
$2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of
live time. Under the same conditions, the discovery sensitivity after $3$
months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr,
respectively.
-
Scintillating, cryogenic bolometers are widely used in the field of rare
event searches. Their main advantages are an excellent energy resolution and
particle identification on an event-by-event basis. The sensitivity of
experiments applying this detector technique can be limited by the performance
of the light channel and the presence of external backgrounds in the region of
interest. In the framework of the CRESST-II experiment, we developed and
successfully tested a novel detector design addressing both challenges. Using a
large scale ($\approx$\unit[60]{cm$^2$}), beaker-shaped silicon light absorber,
the signal height recorded in the light channel is improved by a factor 2.5
compared to conventional CRESTT-II detector modules. In combination with a
large carrier crystal, a true $4\pi$ veto system is established which allows to
tag external background sources.
-
Identifying the nature and origin of dark matter is one of the major
challenges for modern astro and particle physics. Direct dark-matter searches
aim at an observation of dark-matter particles interacting within detectors.
The focus of several such searches is on interactions with nuclei as provided
e.g. by Weakly Interacting Massive Particles. However, there is a variety of
dark-matter candidates favoring interactions with electrons rather than with
nuclei. One example are dark photons, i.e., long-lived vector particles with a
kinetic mixing to standard-model photons. In this work we present constraints
on this kinetic mixing based on data from CRESST-II Phase 2 corresponding to an
exposure before cuts of 52\,kg-days. These constraints improve the existing
ones for dark-photon masses between 0.3 and 0.7\,keV/c$^2$.
-
We report on the measurement of the two-neutrino double beta decay half-life
of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of
TeO$_2$, the half-life is determined to be $T_{1/2}^{2\nu}$ = [8.2 $\pm$ 0.2
(stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a
detailed reconstruction of the sources responsible for the CUORE-0 counting
rate, with a specific study of those contributing to the $^{130}$Te
neutrinoless double beta decay region of interest.
-
The CRESST experiment (Cryogenic Rare Event Search with Superconducting
Thermometers) searches for dark matter via the phonon and light signals of
elastic scattering processes in scintillating crystals. The discrimination
between a possible dark matter signal and background is based on the light
yield. We present a new method for evaluating the two characteristics of a
phonon/light detector module that determine how much of the deposited energy is
converted to scintillation light and how efficiently a module detects the
produced light. In contrast to former approaches with dedicated setups, we
developed a method which allows us to use data taken with the cryogenic setup,
during a dark matter search phase. In this way, we accounted for the entire
process that occurs in a detector module, and obtained information on the light
emission of the crystal as well as information on the performance of the module
(light transport and detection). We found that with the detectors operated in
CRESST-II phase 1, about 20% of the produced scintillation light is detected. A
part of the light is likely absorbed by creating meta-stable excitations in the
scintillating crystals. The light not detected is not absorbed entirely, as an
additional light detector can help to increase the fraction of detected light.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton
scale bolometric experiment devoted to the search of the neutrinoless
double-beta decay (0{\nu}\b{eta}\b{eta}) in 130Te. The CUORE detector consists
of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE
demonstrator: it has been built to test the performance of the upcoming CUORE
experiment and represents the largest 130Te bolometric setup ever operated.
CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from
2013 to 2015. The final CUORE-0 analysis on 0{\nu}\b{eta}\b{eta} and the
corresponding detector performance are presented. The present status of the
CUORE experiment, now in its final construction and commissioning phase, are
discussed. The results from assembly of the detector and the commissioning of
the cryostat are reported.
-
We analyzed low-background data from the CRESST-II experiment with a total
net exposure of 730 kg days to extract limits on double electron capture
processes. We established new limits for $^{40}$Ca with
$T_{1/2}^{2v2K}>9.9\times10^{21}$ y and $T_{1/2}^{0v2EC}>1.4\times10^{22}$ y
and for $^{180}$W with T$_{1/2}^{2v2K}>3.1\times10^{19}$ y and
$T_{1/2}^{0v2EC}>9.4\times10^{18}$ y at 90% CL. Depending on the process, these
values improve the currently best limits by a factor of $\sim$1.4-30.
-
The usual assumption in direct dark matter searches is to only consider the
spin-dependent or spin-independent scattering of dark matter particles.
However, especially in models with light dark matter particles
$\mathcal{O}(\mathrm{GeV/c^2})$, operators which carry additional powers of the
momentum transfer $q^2$ can become dominant. One such model based on asymmetric
dark matter has been invoked to overcome discrepancies in helioseismology and
an indication was found for a particle with preferred mass of 3
$\mathrm{GeV/c^2}$ and cross section of $10^{-37} \mathrm{cm^2}$. Recent data
from the CRESST-II experiment, which uses cryogenic detectors based on
$\mathrm{CaWO_4}$ to search for nuclear recoils induced by dark matter
particles, are used to constrain these momentum-dependent models. The low
energy threshold of 307 eV for nuclear recoils of the detector used, allows us
to rule out the proposed best fit value above.
-
The CUORE experiment will search for neutrinoless double-beta decay of
$^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers.
CUORE-0, the first tower assembled according to the CUORE procedures, was built
and commissioned at Laboratori Nazionali del Gran Sasso, and took data from
March 2013 to March 2015. In this paper we describe the design, construction
and operation of the CUORE-0 experiment, with an emphasis on the improvements
made over a predecessor experiment, Cuoricino. In particular, we demonstrate
with CUORE-0 data that the design goals of CUORE are within reach.
-
We describe in detail the methods used to obtain the lower bound on the
lifetime of neutrinoless double-beta ($0\nu\beta\beta$) decay in $^{130}$Te and
the associated limit on the effective Majorana mass of the neutrino using the
CUORE-0 detector. CUORE-0 is a bolometric detector array located at the
Laboratori Nazionali del Gran Sasso that was designed to validate the
background reduction techniques developed for CUORE, a next-generation
experiment scheduled to come online in 2016. CUORE-0 is also a competitive
$0\nu\beta\beta$ decay search in its own right and functions as a platform to
further develop the analysis tools and procedures to be used in CUORE. These
include data collection, event selection and processing, as well as an
evaluation of signal efficiency. In particular, we describe the amplitude
evaluation, thermal gain stabilization, energy calibration methods, and the
analysis event selection used to create our final $0\nu\beta\beta$ decay search
spectrum. We define our high level analysis procedures, with emphasis on the
new insights gained and challenges encountered. We outline in detail our
fitting methods near the hypothesized $0\nu\beta\beta$ decay peak and catalog
the main sources of systematic uncertainty. Finally, we derive the
$0\nu\beta\beta$ decay half-life limits previously reported for CUORE-0,
$T^{0\nu}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino
limit, $T^{0\nu}_{1/2}>4.0\times10^{24}$ yr.
-
The cryogenic underground observatory for rare events (CUORE) is a 1-ton
scale bolometric experiment whose detector consists of an array of 988 TeO2
crystals arranged in a cylindrical compact structure of 19 towers. This will be
the largest bolometric mass ever operated. The experiment will work at a
temperature around or below 10 mK. CUORE cryostat consists of a cryogen-free
system based on pulse tubes and a custom high power dilution refrigerator,
designed to match these specifications. The cryostat has been commissioned in
2014 at the Gran Sasso National Laboratories and reached a record temperature
of 6 mK on a cubic meter scale. In this paper, we present results of CUORE
commissioning runs. Details on the thermal characteristics and cryogenic
performances of the system will be also given.
-
The CRESST-II experiment uses cryogenic detectors to search for nuclear
recoil events induced by the elastic scattering of dark matter particles in
CaWO$_4$ crystals. Given the low energy threshold of our detectors in
combination with light target nuclei, low mass dark matter particles can be
probed with high sensitivity. In this letter we present the results from data
of a single detector module corresponding to 52 kg live days. A blind analysis
is carried out. With an energy threshold for nuclear recoils of 307 eV we
substantially enhance the sensitivity for light dark matter. Thereby, we extend
the reach of direct dark matter experiments to the sub-region and demonstrate
that the energy threshold is the key parameter in the search for low mass dark
matter particles.
-
The experiment CRESST-II aims at the detection of dark matter with
scintillating CaWO$_4$ crystals operated as cryogenic detectors. Recent results
on spin-independent WIMP-nucleon scattering from the CRESST-II Phase 2 allowed
to probe a new region of parameter space for WIMP masses below 3 GeV/c$^2$.
This sensitivity was achieved after background levels were reduced
significantly. We present extensive background studies of a CaWO$_4$ crystal,
called TUM40, grown at the Technische Universit\"at M\"unchen. The average
beta/gamma rate of 3.51/[kg keV day] (1-40 keV) and the total intrinsic alpha
activity from natural decay chains of $3.08\pm0.04$ mBq/kg are the lowest
reported for CaWO$_4$ detectors. Contributions from cosmogenic activation,
surface-alpha decays, external radiation and intrinsic alpha/beta emitters are
investigated in detail. A Monte-Carlo based background decomposition allows to
identify the origin of the majority of beta/gamma events in the energy region
relevant for dark matter search.
-
The cryogenic dark matter experiment CRESST-II aims at the direct detection
of WIMPs via elastic scattering off nuclei in scintillating CaWO$_4$ crystals.
We present a new, highly improved, detector design installed in the current run
of CRESST-II Phase 2 with an efficient active rejection of surface-alpha
backgrounds. Using CaWO$_4$ sticks instead of metal clamps to hold the target
crystal, a detector housing with fully-scintillating inner surface could be
realized. The presented detector (TUM40) provides an excellent threshold of
${\sim}\,0.60\,$keV and a resolution of $\sigma\,{\approx}\,0.090$ keV (at
2.60$\,$keV). With significantly reduced background levels, TUM40 sets
stringent limits on the spin-independent WIMP-nucleon scattering cross section
and probes a new region of parameter space for WIMP masses below
3$\,$GeV/c$^2$. In this paper, we discuss the novel detector design and the
surface-alpha event rejection in detail.