-
Possibilities to test the Lorentz invariance of the weak interaction in muon
decay are considered. We derive the direction-dependent muon-decay rate with a
general Lorentz-violating addition to the W-boson propagator. We discuss
measurements of the directional and boost dependence of the Michel parameters
and of the muon lifetime as a function of absolute velocity. The total
muon-decay rate in the Lorentz-violating Standard Model Extension is addressed.
Suggestions are made for dedicated (re)analyses of the pertinent data and for
future experiments.
-
We present a detailed report of the method, setup, analysis and results of a
precision measurement of the positive muon lifetime. The experiment was
conducted at the Paul Scherrer Institute using a time-structured, nearly
100%-polarized, surface muon beam and a segmented, fast-timing, plastic
scintillator array. The measurement employed two target arrangements; a
magnetized ferromagnetic target with a ~4 kG internal magnetic field and a
crystal quartz target in a 130 G external magnetic field. Approximately 1.6 x
10^{12} positrons were accumulated and together the data yield a muon lifetime
of tau_{mu}(MuLan) = 2196980.3(2.2) ps (1.0 ppm), thirty times more precise
than previous generations of lifetime experiments. The lifetime measurement
yields the most accurate value of the Fermi constant G_F (MuLan) = 1.1663787(6)
x 10^{-5} GeV^{-2} (0.5 ppm). It also enables new precision studies of weak
interactions via lifetime measurements of muonic atoms.
-
We present some aspects of photon counting to study scintillators at low
temperatures. A time-to-digital converter (TDC) had been configured to acquire
several-minute-long streams of data, simplifying the multiple photon counting
coincidence technique. Results in terms of light yield and time structure of a
ZnWO4 scintillator are comparable to those obtained with a fast digitizer.
Streaming data also provides flexibility in analyzing the data, in terms of
coincidence window between the channels, and acquisition window of individual
channels. We discuss the effect of changing these parameters, and use them to
confirm low-energy features in the spectra of the number of detected photons,
such as the 60 keV line from 241Am in the ZnWO4 sample. We lastly use the TDC
to study the transmission of the optical cryostat employed in these studies at
various temperatures.
-
Laser spectroscopy of short-lived radium isotopes in a linear Paul trap has
been performed. The isotope shifts of the $6d\,^2$D$_{3/2}\,$ -
$7p\,^2$P$_{1/2}\,$ transition in $^{209-214}$Ra$^+$ were measured, which are
sensitive to the short range part of the atomic wavefunctions. The results are
essential experimental input for improving the precision of atomic structure
calculation. This is indispensable for parity violation in Ra$^+$ aiming at the
determination of the weak mixing angle.
-
As an important step towards an atomic parity violation experiment in one
single trapped Ra$^+$ ion, laser spectroscopy experiments were performed with
on-line produced short-lived $^{212,213,214}$Ra$^+$ ions. The isotope shift of
the $6\,^2$D$_{3/2}$\,-\,$7\,^2$P$_{1/2}$ and
$6\,^2$D$_{3/2}$\,-\,$7\,^2$P$_{3/2}$ transitions and the hyperfine structure
constant of the $7\,^2$S$_{1/2}$ and $6\,^2$D$_{3/2}$ states in $^{213}$Ra$^+$
were measured. These values provide a benchmark for the required atomic theory.
A lower limit of $232(4)$ ms for the lifetime of the metastable
$6\,^2$D$_{5/2}$ state was measured by optical shelving.
-
Efficient production of short-lived radioactive isotopes in inverse reaction
kinematics is an important technique for various applications. It is
particularly interesting when the isotope of interest is only a few nucleons
away from a stable isotope. In this article production via charge exchange and
stripping reactions in combination with a magnetic separator is explored. The
relation between the separator transmission efficiency, the production yield,
and the choice of beam energy is discussed. The results of some exploratory
experiments will be presented.
-
The aim of the MuCap experiment is a 1% measurement of the singlet capture
rate Lambda_S for the basic electro-weak reaction mu + p -> n + nu_mu. This
observable is sensitive to the weak form-factors of the nucleon, in particular
to the induced pseudoscalar coupling constant g_P. It will provide a rigorous
test of theoretical predictions based on the Standard Model and effective
theories of QCD. The present method is based on high precision lifetime
measurements of mu^- in hydrogen gas and the comparison with the free mu^+
lifetime. The mu^- experiment will be performed in ultra-clean,
deuterium-depleted H_2 gas at 10 bar. Low density compared to liquid H_2 is
chosen to avoid uncertainties due to ppmu formation. A time projection chamber
acts as a pure hydrogen active target. It defines the muon stop position in 3-D
and detects rare background reactions. Decay electrons are tracked in
cylindrical wire-chambers and a scintillator array covering 75% of 4 pi.