-
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With construction well underway, LZ
is on track for underground installation at SURF in 2019 and will start
collecting data in 2020.
-
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle
interactions with a detector containing a total of 10 tonnes of liquid xenon
within a double-vessel cryostat. The large mass and proximity of the cryostat
to the active detector volume demand the use of material with extremely low
intrinsic radioactivity. We report on the radioassay campaign conducted to
identify suitable metals, the determination of factors limiting radiopure
production, and the selection of titanium for construction of the LZ cryostat
and other detector components. This titanium has been measured with activities
of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg,
$^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm
0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL).
Such low intrinsic activities, which are some of the lowest ever reported for
titanium, enable its use for future dark matter and other rare event searches.
Monte Carlo simulations have been performed to assess the expected background
contribution from the LZ cryostat with this radioactivity. In 1,000 days of
WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute
only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
-
In this Technical Design Report (TDR) we describe the LZ detector to be built
at the Sanford Underground Research Facility (SURF). The LZ dark matter
experiment is designed to achieve sensitivity to a WIMP-nucleon
spin-independent cross section of three times ten to the negative forty-eighth
square centimeters.
-
Two-neutrino double electron capture is a rare nuclear decay where two
electrons are simultaneously captured from the atomic shell. For $^{124}$Xe
this process has not yet been observed and its detection would provide a new
reference for nuclear matrix element calculations. We have conducted a search
for two-neutrino double electron capture from the K-shell of $^{124}$Xe using
7636 kg$\cdot$d of data from the XENON100 dark matter detector. Using a
Bayesian analysis we observed no significant excess above background, leading
to a lower 90 % credibility limit on the half-life $T_{1/2}>6.5\times10^{20}$
yr. We also evaluated the sensitivity of the XENON1T experiment, which is
currently being commissioned, and find a sensitivity of
$T_{1/2}>6.1\times10^{22}$ yr after an exposure of 2 t$\cdot$yr.
-
We report on WIMP search results of the XENON100 experiment, combining three
runs summing up to 477 live days from January 2010 to January 2014. Data from
the first two runs were already published. A blind analysis was applied to the
last run recorded between April 2013 and January 2014 prior to combining the
results. The ultra-low electromagnetic background of the experiment, ~$5 \times
10^{-3}$ events/(keV$_{\mathrm{ee}}\times$kg$\times$day) before electronic
recoil rejection, together with the increased exposure of 48 kg $\times$ yr
improves the sensitivity. A profile likelihood analysis using an energy range
of (6.6 - 43.3) keV$_{\mathrm{nr}}$ sets a limit on the elastic,
spin-independent WIMP-nucleon scattering cross section for WIMP masses above 8
GeV/$c^2$, with a minimum of 1.1 $\times 10^{-45}$ cm$^2$ at 50 GeV/$c^2$ and
90% confidence level. We also report updated constraints on the elastic,
spin-dependent WIMP-nucleon cross sections obtained with the same data. We set
upper limits on the WIMP-neutron (proton) cross section with a minimum of 2.0
$\times 10^{-40}$ cm$^2$ (52$\times 10^{-40}$ cm$^2$) at a WIMP mass of 50
GeV/$c^2$, at 90% confidence level.
-
We present the first results of searches for axions and axion-like-particles
with the XENON100 experiment. The axion-electron coupling constant, $g_{Ae}$,
has been probed by exploiting the axio-electric effect in liquid xenon. A
profile likelihood analysis of 224.6 live days $\times$ 34 kg exposure has
shown no evidence for a signal. By rejecting $g_{Ae}$, larger than $7.7 \times
10^{-12}$ (90\% CL) in the solar axion search, we set the best limit to date on
this coupling. In the frame of the DFSZ and KSVZ models, we exclude QCD axions
heavier than 0.3 eV/c$^2$ and 80 eV/c$^2$, respectively. For
axion-like-particles, under the assumption that they constitute the whole
abundance of dark matter in our galaxy, we constrain $g_{Ae}$, to be lower than
$1 \times 10^{-12}$ (90\% CL) for mass range from 1 to 40 keV/c$^2$, and set
the best limit to date as well.
-
We perform a low-mass dark matter search using an exposure of
30\,kg$\times$yr with the XENON100 detector. By dropping the requirement of a
scintillation signal and using only the ionization signal to determine the
interaction energy, we lowered the energy threshold for detection to 0.7\,keV
for nuclear recoils. No dark matter detection can be claimed because a complete
background model cannot be constructed without a primary scintillation signal.
Instead, we compute an upper limit on the WIMP-nucleon scattering cross section
under the assumption that every event passing our selection criteria could be a
signal event. Using an energy interval from 0.7\,keV to 9.1\,keV, we derive a
limit on the spin-independent WIMP-nucleon cross section that excludes WIMPs
with a mass of 6\,GeV/$c^2$ above $1.4 \times 10^{-41}$\,cm$^2$ at 90\%
confidence level.
-
The XENON1T experiment is currently in the commissioning phase at the
Laboratori Nazionali del Gran Sasso, Italy. In this article we study the
experiment's expected sensitivity to the spin-independent WIMP-nucleon
interaction cross section, based on Monte Carlo predictions of the electronic
and nuclear recoil backgrounds.
The total electronic recoil background in $1$ tonne fiducial volume and ($1$,
$12$) keV electronic recoil equivalent energy region, before applying any
selection to discriminate between electronic and nuclear recoils, is $(1.80 \pm
0.15) \cdot 10^{-4}$ ($\rm{kg} \cdot day \cdot keV)^{-1}$, mainly due to the
decay of $^{222}\rm{Rn}$ daughters inside the xenon target. The nuclear recoil
background in the corresponding nuclear recoil equivalent energy region ($4$,
$50$) keV, is composed of $(0.6 \pm 0.1)$ ($\rm{t} \cdot y)^{-1}$ from
radiogenic neutrons, $(1.8 \pm 0.3) \cdot 10^{-2}$ ($\rm{t} \cdot y)^{-1}$ from
coherent scattering of neutrinos, and less than $0.01$ ($\rm{t} \cdot y)^{-1}$
from muon-induced neutrons.
The sensitivity of XENON1T is calculated with the Profile Likelihood Ratio
method, after converting the deposited energy of electronic and nuclear recoils
into the scintillation and ionization signals seen in the detector. We take
into account the systematic uncertainties on the photon and electron emission
model, and on the estimation of the backgrounds, treated as nuisance
parameters. The main contribution comes from the relative scintillation
efficiency $\mathcal{L}_\mathrm{eff}$, which affects both the signal from WIMPs
and the nuclear recoil backgrounds. After a $2$ y measurement in $1$ t fiducial
volume, the sensitivity reaches a minimum cross section of $1.6 \cdot 10^{-47}$
cm$^2$ at m$_\chi$=$50$ GeV/$c^2$.
-
The search for dark matter is one of today's most exciting fields. As bigger
detectors are being built to increase their sensitivity, background reduction
is an ever more challenging issue. To this end, a new type of dark matter
detector is proposed, a xenon bubble chamber, which would combine the strengths
of liquid xenon TPCs, namely event by event energy resolution, with those of a
bubble chamber, namely insensitivity to electronic recoils. In addition, it
would be the first time ever that a dark matter detector is active on all three
detection channels, ionization and scintillation characteristic of xenon
detectors, and heat through bubble formation in superheated fluids. Preliminary
simulations show that, depending on threshold, a discrimination of 99.99\% to
99.9999+\% can be achieved, which is on par or better than many current
experiments. A prototype is being built at the University at Albany, SUNY. The
prototype is currently undergoing seals, thermal, and compression testing.
-
Laboratory experiments searching for galactic dark matter particles
scattering off nuclei have so far not been able to establish a discovery. We
use data from the XENON100 experiment to search for dark matter interacting
with electrons. With no evidence for a signal above the low background of our
experiment, we exclude a variety of representative dark matter models that
would induce electronic recoils. For axial-vector couplings to electrons, we
exclude cross-sections above 6x10^(-35) cm^2 for particle masses of m_chi = 2
GeV/c^2. Independent of the dark matter halo, we exclude leptophilic models as
explanation for the long-standing DAMA/LIBRA signal, such as couplings to
electrons through axial-vector interactions at a 4.4 sigma confidence level,
mirror dark matter at 3.6 sigma, and luminous dark matter at 4.6 sigma.
-
We have searched for periodic variations of the electronic recoil event rate
in the (2-6) keV energy range recorded between February 2011 and March 2012
with the XENON100 detector, adding up to 224.6 live days in total. Following a
detailed study to establish the stability of the detector and its background
contributions during this run, we performed an un-binned profile likelihood
analysis to identify any periodicity up to 500 days. We find a global
significance of less than 1 sigma for all periods suggesting no statistically
significant modulation in the data. While the local significance for an annual
modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and
the phase of the modulation disfavor a dark matter interpretation. The
DAMA/LIBRA annual modulation interpreted as a dark matter signature with
axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
-
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410
has been developed by Hamamatsu for dark matter direct detection experiments
using liquid xenon as the target material. We present the results from the
joint effort between the XENON collaboration and the Hamamatsu company to
produce a highly radio-pure photosensor (version R11410-21) for the XENON1T
dark matter experiment. After introducing the photosensor and its components,
we show the methods and results of the radioactive contamination measurements
of the individual materials employed in the photomultiplier production. We then
discuss the adopted strategies to reduce the radioactivity of the various PMT
versions. Finally, we detail the results from screening 216 tubes with
ultra-low background germanium detectors, as well as their implications for the
expected electronic and nuclear recoil background of the XENON1T experiment.
-
XENON is a dark matter direct detection project, consisting of a time
projection chamber (TPC) filled with liquid xenon as detection medium. The
construction of the next generation detector, XENON1T, is presently taking
place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a
sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~
\mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires
a background reduction by two orders of magnitude compared to XENON100, the
current generation detector. An active system that is able to tag muons and
muon-induced backgrounds is critical for this goal. A water Cherenkov detector
of $\sim$10 m height and diameter has been therefore developed, equipped with 8
inch photomultipliers and cladded by a reflective foil. We present the design
and optimization study for this detector, which has been carried out with a
series of Monte Carlo simulations. The muon veto will reach very high detection
efficiencies for muons ($>99.5%$) and showers of secondary particles from muon
interactions in the rock ($>70%$). Similar efficiencies will be obtained for
XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity
by another order of magnitude. With the Cherenkov water shield studied here,
the background from muon-induced neutrons in XENON1T is negligible.
-
The radioactive isomer $^{83\mathrm{m}}$Kr has many properties that make it
very useful for various applications. Its low energy decay products, like
conversion, shake-off and Auger electrons as well as X- and $\gamma$-rays are
used for calibration purposes in neutrino mass experiments and direct dark
matter detection experiments. Thanks to the short half-life of 1.83 h and the
decay to the ground state $^{83}$Kr, one does not risk contamination of any
low-background experiment with long- lived radionuclides. In this paper, we
present two new applications of $^{83\mathrm{m}}$Kr. It can be used as a
radioactive tracer in noble gases to characterize the particle flow inside of
gas routing systems. A method of doping $^{83\mathrm{m}}$Kr into xenon gas and
its detection, using special custom-made detectors, based on a photomultiplier
tube, is described. This technique has been used to determine the circulation
speed of gas particles inside of a gas purification system for xenon.
Furthermore, 83m Kr can be used to rapidly estimate separation performance of a
distillation system.
-
The XENON100 dark matter experiment uses liquid xenon in a time projection
chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of
dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we
report the observation of single-electron charge signals which are not related
to WIMP interactions. These signals, which show the excellent sensitivity of
the detector to small charge signals, are explained as being due to the
photoionization of impurities in the liquid xenon and of the metal components
inside the TPC. They are used as a unique calibration source to characterize
the detector. We explain how we can infer crucial parameters for the XENON100
experiment: the secondary-scintillation gain, the extraction yield from the
liquid to the gas phase and the electron drift velocity.
-
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso,
aims at the direct detection of dark matter in the form of weakly interacting
massive particles (WIMPs), based on their interactions with xenon nuclei in an
ultra low background dual-phase time projection chamber. This paper describes
the general methods developed for the analysis of the XENON100 data. These
methods have been used in the 100.9 and 224.6 live days science runs from which
results on spin-independent elastic, spin-dependent elastic and inelastic
WIMP-nucleon cross-sections have already been reported.
-
Results from the nuclear recoil calibration of the XENON100 dark matter
detector installed underground at the Laboratori Nazionali del Gran Sasso
(LNGS), Italy are presented. Data from measurements with an external 241AmBe
neutron source are compared with a detailed Monte Carlo simulation which is
used to extract the energy dependent charge-yield Qy and relative scintillation
efficiency Leff. A very good level of absolute spectral matching is achieved in
both observable signal channels - scintillation S1 and ionization S2 - along
with agreement in the 2-dimensional particle discrimination space. The results
confirm the validity of the derived signal acceptance in earlier reported dark
matter searches of the XENON100 experiment.
-
We report on a search for particle dark matter with the XENON100 experiment,
operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during
2011 and 2012. XENON100 features an ultra-low electromagnetic background of
(5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of
interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded
no evidence for dark matter interactions. The two candidate events observed in
the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent
with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood
analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on
the spin-independent elastic WIMP-nucleon scattering cross section for WIMP
masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2
and 90% confidence level.
-
We present new experimental constraints on the elastic, spin-dependent
WIMP-nucleon cross section using recent data from the XENON100 experiment,
operated in the Laboratori Nazionali del Gran Sasso in Italy. An analysis of
224.6 live days x 34 kg of exposure acquired during 2011 and 2012 revealed no
excess signal due to axial-vector WIMP interactions with 129-Xe and 131-Xe
nuclei. This leads to the most stringent upper limits on WIMP-neutron cross
sections for WIMP masses above 6 GeV, with a minimum cross section of 3.5 x
10^{-40} cm^2 at a WIMP mass of 45 GeV, at 90% confidence level.
-
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran
Sasso (LNGS) in Italy, was designed to search for evidence of dark matter
interactions inside a volume of liquid xenon using a dual-phase time projection
chamber. This paper describes the Slow Control System (SCS) of the experiment
with emphasis on the distributed architecture as well as on its modular and
expandable nature. The system software was designed according to the rules of
Object-Oriented Programming and coded in Java, thus promoting code reusability
and maximum flexibility during commissioning of the experiment. The SCS has
been continuously monitoring the XENON100 detector since mid 2008, remotely
recording hundreds of parameters on a few dozen instruments in real time, and
setting emergency alarms for the most important variables.
-
In a recent manuscript (arXiv:1208.5046) Peter Sorensen claims that
XENON100's upper limits on spin-independent WIMP-nucleon cross sections for
WIMP masses below 10 GeV "may be understated by one order of magnitude or
more". Having performed a similar, though more detailed analysis prior to the
submission of our new result (arXiv:1207.5988), we do not confirm these
findings. We point out the rationale for not considering the described effect
in our final analysis and list several potential problems with his study.
-
The spectral action for a non-compact commutative spectral triple is computed
covariantly in a gauge perturbation up to order 2 in full generality. In the
ultraviolet regime, $p\to\infty$, the action decays as $1/p^4$ in any even
dimension.
-
Recent results from the PICASSO dark matter search experiment at SNOLAB are
reported. These results were obtained using a subset of 10 detectors with a
total target mass of 0.72 kg of 19F and an exposure of 114 kgd. The low
backgrounds in PICASSO allow recoil energy thresholds as low as 1.7 keV to be
obtained which results in an increased sensitivity to interactions from Weakly
Interacting Massive Particles (WIMPs) with masses below 10 GeV/c^2. No dark
matter signal was found. Best exclusion limits in the spin dependent sector
were obtained for WIMP masses of 20 GeV/c^2 with a cross section on protons of
sigma_p^SD = 0.032 pb (90% C.L.). In the spin independent sector close to the
low mass region of 7 GeV/c2 favoured by CoGeNT and DAMA/LIBRA, cross sections
larger than sigma_p^SI = 1.41x10^-4 pb (90% C.L.) are excluded.
-
The XENON100 experiment has recently completed a dark matter run with 100.9
live-days of data, taken from January to June 2010. Events in a 48kg fiducial
volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A
total of three events have been found in the predefined signal region,
compatible with the background prediction of (1.8 \pm 0.6) events. Based on
this analysis we present limits on the WIMP-nucleon cross section for inelastic
dark matter. With the present data we are able to rule out the explanation for
the observed DAMA/LIBRA modulation as being due to inelastic dark matter
scattering off iodine at a 90% confidence level.
-
We present results from the direct search for dark matter with the XENON100
detector, installed underground at the Laboratori Nazionali del Gran Sasso of
INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg
liquid xenon target. Interaction vertex reconstruction in three dimensions with
millimeter precision allows to select only the innermost 48 kg as ultra-low
background fiducial target. In 100.9 live days of data, acquired between
January and June 2010, no evidence for dark matter is found. Three candidate
events were observed in a pre-defined signal region with an expected background
of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter
interactions today, excluding spin-independent elastic WIMP-nucleon scattering
cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90%
confidence level.