-
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With construction well underway, LZ
is on track for underground installation at SURF in 2019 and will start
collecting data in 2020.
-
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle
interactions with a detector containing a total of 10 tonnes of liquid xenon
within a double-vessel cryostat. The large mass and proximity of the cryostat
to the active detector volume demand the use of material with extremely low
intrinsic radioactivity. We report on the radioassay campaign conducted to
identify suitable metals, the determination of factors limiting radiopure
production, and the selection of titanium for construction of the LZ cryostat
and other detector components. This titanium has been measured with activities
of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg,
$^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm
0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL).
Such low intrinsic activities, which are some of the lowest ever reported for
titanium, enable its use for future dark matter and other rare event searches.
Monte Carlo simulations have been performed to assess the expected background
contribution from the LZ cryostat with this radioactivity. In 1,000 days of
WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute
only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
-
A 30-g xenon bubble chamber, operated at Northwestern University in June and
November 2016, has for the first time observed simultaneous bubble nucleation
and scintillation by nuclear recoils in a superheated liquid. This chamber is
instrumented with a CCD camera for near-IR bubble imaging, a solar-blind
photomultiplier tube to detect 175-nm xenon scintillation light, and a
piezoelectric acoustic transducer to detect the ultrasonic emission from a
growing bubble. The time of nucleation determined from the acoustic signal is
used to correlate specific scintillation pulses with bubble-nucleating events.
We report on data from this chamber for thermodynamic "Seitz" thresholds from
4.2 to 15.0 keV. The observed single- and multiple-bubble rates when exposed to
a $^{252}$Cf neutron source indicate that, for an 8.3-keV thermodynamic
threshold, the minimum nuclear recoil energy required to nucleate a bubble is
$19\pm6$ keV (1$\sigma$ uncertainty). This is consistent with the observed
scintillation spectrum for bubble-nucleating events. We see no evidence for
bubble nucleation by gamma rays at any of the thresholds studied, setting a 90%
C.L. upper limit of $6.3\times10^{-7}$ bubbles per gamma interaction at a
4.2-keV thermodynamic threshold. This indicates stronger gamma discrimination
than in CF$_3$I bubble chambers, supporting the hypothesis that scintillation
production suppresses bubble nucleation by electron recoils while nuclear
recoils nucleate bubbles as usual. These measurements establish the
noble-liquid bubble chamber as a promising new technology for the detection of
weakly interacting massive particle dark matter and coherent elastic
neutrino-nucleus scattering.
-
In this Technical Design Report (TDR) we describe the LZ detector to be built
at the Sanford Underground Research Facility (SURF). The LZ dark matter
experiment is designed to achieve sensitivity to a WIMP-nucleon
spin-independent cross section of three times ten to the negative forty-eighth
square centimeters.
-
We have directly measured the energy threshold and efficiency for bubble
nucleation from iodine recoils in a CF3I bubble chamber in the energy range of
interest for a dark matter search. These interactions cannot be probed by
standard neutron calibration methods, so we develop a new technique by
observing the elastic scattering of 12 GeV/c negative pions. The pions are
tracked with a silicon pixel telescope and the reconstructed scattering angle
provides a measure of the nuclear recoil kinetic energy. The bubble chamber was
operated with a nominal threshold of (13.6+-0.6) keV. Interpretation of the
results depends on the response to fluorine and carbon recoils, but in general
we find agreement with the predictions of the classical bubble nucleation
theory. This measurement confirms the applicability of CF3I as a target for
spin-independent dark matter interactions and represents a novel technique for
calibration of superheated fluid detectors.
-
We report results of a search for light (<10 GeV) particle dark matter with
the XENON10 detector. The event trigger was sensitive to a single electron,
with the analysis threshold of 5 electrons corresponding to 1.4 keV nuclear
recoil energy. Considering spin-independent dark matter-nucleon scattering, we
exclude cross sections \sigma_n>3.5x10^{-42} cm^2, for a dark matter particle
mass m_{\chi}=8 GeV. We find that our data strongly constrain recent elastic
dark matter interpretations of excess low-energy events observed by CoGeNT and
CRESST-II, as well as the DAMA annual modulation signal.
-
New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber
in the 6800-foot-deep SNOLAB underground laboratory. The effectiveness of
ultrasound analysis in discriminating alpha-decay background events from single
nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of
alpha-decay events. Twenty single nuclear recoil event candidates and three
multiple bubble events were observed during a total exposure of 553 kg-days
distributed over three different bubble nucleation thresholds. The effective
exposure for single bubble recoil-like events was 437.4 kg-days. A neutron
background internal to the apparatus, of known origin, is estimated to account
for five single nuclear recoil events and is consistent with the observed rate
of multiple bubble events. This observation provides world best direct
detection constraints on WIMP-proton spin-dependent scattering for WIMP masses
$>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent
interactions.
-
The SIMPLE Collaboration has reported results from their superheated C2ClF5
droplet detectors, including a description of acoustic discrimination between
\alpha decays and nuclear recoils. Our concern is that the events in the
neutron calibration data and the events identified as neutrons in the physics
data are not drawn from the same parent distribution. This fact calls into
question the identification of the background events as neutrons, the use of
the calibration data to define the acceptance of WIMP-induced nuclear recoils,
and the observation of discrimination against \alpha's.
-
Data from the operation of a bubble chamber filled with 3.5 kg of CF$_{3}$I
in a shallow underground site are reported. An analysis of ultrasound signals
accompanying bubble nucleations confirms that alpha decays generate a
significantly louder acoustic emission than single nuclear recoils, leading to
an efficient background discrimination. Three dark matter candidate events were
observed during an effective exposure of 28.1 kg-day, consistent with a neutron
background. This observation provides the strongest direct detection constraint
to date on WIMP-proton spin-dependent scattering for WIMP masses $>20$
GeV/c$^{2}$.
-
We show that the energy threshold for nuclear recoils in the XENON10 dark
matter search data can be lowered to ~1 keV, by using only the ionization
signal. In other words, we make no requirement that a valid event contain a
primary scintillation signal. We therefore relinquish incident particle type
discrimination, which is based on the ratio of ionization to scintillation in
liquid xenon. This method compromises the detector's ability to precisely
determine the z coordinate of a particle interaction. However, we show for the
first time that it is possible to discriminate bulk events from surface events
based solely on the ionization signal.
-
It has been suggested that dark matter particles which scatter inelastically
from detector target nuclei could explain the apparent incompatibility of the
DAMA modulation signal (interpreted as evidence for particle dark matter) with
the null results from CDMS-II and XENON10. Among the predictions of
inelastically interacting dark matter are a suppression of low-energy events,
and a population of nuclear recoil events at higher nuclear recoil equivalent
energies. This is in stark contrast to the well-known expectation of a falling
exponential spectrum for the case of elastic interactions. We present a new
analysis of XENON10 dark matter search data extending to E$_{nr}=75$ keV
nuclear recoil equivalent energy. Our results exclude a significant region of
previously allowed parameter space in the model of inelastically interacting
dark matter. In particular, it is found that dark matter particle masses
$m_{\chi}\gtrsim150$ GeV are disfavored.
-
XENON10 is the first two-phase xenon time projection chamber (TPC) developed
within the XENON dark matter search program. The TPC, with an active liquid
xenon (LXe) mass of about 14 kg, was installed at the Gran Sasso underground
laboratory (LNGS) in Italy, and operated for more than one year, with excellent
stability and performance. Results from a dark matter search with XENON10 have
been published elsewhere. In this paper, we summarize the design and
performance of the detector and its subsystems, based on calibration data using
sources of gamma-rays and neutrons as well as background and Monte Carlo
simulations data. The results on the detector's energy threshold, energy and
position resolution, and overall efficiency show a performance that exceeds
design specifications, in view of the very low energy threshold achieved (<10
keVr) and the excellent energy resolution achieved by combining the ionization
and scintillation signals, detected simultaneously.
-
XENON10 is an experiment designed to directly detect particle dark matter. It
is a dual phase (liquid/gas) xenon time-projection chamber with 3D position
imaging. Particle interactions generate a primary scintillation signal (S1) and
ionization signal (S2), which are both functions of the deposited recoil energy
and the incident particle type. We present a new precision measurement of the
relative scintillation yield \leff and the absolute ionization yield Q_y, for
nuclear recoils in xenon. A dark matter particle is expected to deposit energy
by scattering from a xenon nucleus. Knowledge of \leff is therefore crucial for
establishing the energy threshold of the experiment; this in turn determines
the sensitivity to particle dark matter. Our \leff measurement is in agreement
with recent theoretical predictions above 15 keV nuclear recoil energy, and the
energy threshold of the measurement is 4 keV. A knowledge of the ionization
yield \Qy is necessary to establish the trigger threshold of the experiment.
The ionization yield \Qy is measured in two ways, both in agreement with
previous measurements and with a factor of 10 lower energy threshold.
-
XENON10 is an experiment to directly detect weakly interacting massive
particle (WIMPs), which may comprise the bulk of the non-baryonic dark matter
in our Universe. We report new results for spin-dependent WIMP-nucleon
interactions with 129-Xe and 131-Xe from 58.6 live-days of operation at the
Laboratori Nazionali del Gran Sasso (LNGS). Based on the non-observation of a
WIMP signal in 5.4 kg of fiducial liquid xenon mass, we exclude previously
unexplored regions in the theoretically allowed parameter space for
neutralinos. We also exclude a heavy Majorana neutrino with a mass in the range
of 10 GeV -2 TeV as a dark matter candidate under standard assumptions for its
density and distribution in the galactic halo.
-
The XENON10 experiment at the Gran Sasso National Laboratory uses a 15 kg
xenon dual phase time projection chamber (XeTPC) to search for dark matter
weakly interacting massive particles (WIMPs). The detector measures
simultaneously the scintillation and the ionization produced by radiation in
pure liquid xenon, to discriminate signal from background down to 4.5 keV
nuclear recoil energy. A blind analysis of 58.6 live days of data, acquired
between October 6, 2006 and February 14, 2007, and using a fiducial mass of 5.4
kg, excludes previously unexplored parameter space, setting a new 90% C.L.
upper limit for the WIMP-nucleon spin-independent cross-section of 8.8 x
10^{-44} cm^2 for a WIMP mass of 100 GeV/c^2, and 4.5 x 10^{-44} cm^2 for a
WIMP mass of 30 GeV/c^2. This result further constrains predictions of
supersymmetric models.
-
We report the first measurements of the absolute ionization yield of nuclear
recoils in liquid xenon, as a function of energy and electric-field.
Independent experiments were carried out with two dual-phase time projection
chamber prototypes, developed for the XENON Dark Matter project. We find that
the charge yield increases with decreasing recoil energy, and exhibits only a
weak field dependence. These results are a first demonstration of the
capability of dual phase xenon detectors to discriminate between electron and
nuclear recoils, a key requirement for a sensitive dark matter search at recoil
energies down to 20 keV.