• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Resistive Plate Chamber Digitization in a Hadronic Shower Environment (1604.04550)

    Z.Deng, Y.Li, Y.Wang, Q.Yue, Z.Yang, J.Apostolakis, G.Folger, C.Grefe, V.Ivantchenko, A.Ribon, V.Uzhinskiy, D.Boumediene, C.Carloganu, V.Français, G.Cho, D-W.Kim, S.C.Lee, W.Park, S.Vallecorsa, S.Cauwenbergh, M.Tytgat, A.Pingault, N.Zaganidis, E.Brianne, A.Ebrahimi, K.Gadow, P.Göttlicher, C.Günter, O.Hartbrich, B.Hermberg, A.Irles, F.Krivan, K.Krüger, J.Kvasnicka, S.Lu, B.Lutz, V.Morgunov, C.Neubüser, A.Provenza, M.Reinecke, F.Sefkow, S.Schuwalow, H.L.Tran, E.Garutti, S.Laurien, M.Matysek, M.Ramilli, S.Schroeder, B.Bilki, E.Norbeck, D.Northacker, Y.Onel, S.Chang, A.Khan, D.H.Kim, D.J.Kong, Y.D.Oh, K.Kawagoe, H.Hirai, Y.Sudo, T.Suehara, H.Sumida, T.Yoshioka, E.Cortina Gil, S.Mannai, V.Buridon, C.Combaret, L.Caponetto, R.Eté, G.Garillot, G.Grenier, R.Han, J.C.Ianigro, R.Kieffer, I.Laktineh, N.Lumb, H.Mathez, L.Mirabito, A.Petrukhin, A.Steen, J.Berenguer Antequera, E.Calvo Alamillo, M.-C.Fouz, J.Marin, J.Puerta-Pelayo, A.Verdugo, M.Chadeeva, M. Danilov, M.Gabriel, P.Goecke, C.Kiesling, N.vanderKolk, F.Simon, M.Szalay, S.Bilokin, J.Bonis, P.Cornebise, F.Richard, R.Pöschl, J.Rouëné, A.Thiebault, D.Zerwas, M.Anduze, V.Balagura, K.Belkadhi, V.Boudry, J-C.Brient, R.Cornat, M.Frotin, F.Gastaldi, Y.Haddad, F.Magniette, M.Ruan, M.Rubio-Roy, K.Shpak, H.Videau, D.Yu, S.Callier, S. Conforti di Lorenzo, F.Dulucq, G.Martin-Chassard, Ch.de la Taille, L.Raux, N.Seguin-Moreau, K.Kotera, H.Ono, T.Takeshita, F.Corriveau
    April 15, 2016 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a three-threshold readout as the active medium. This technology is one of the two options proposed for the hadron calorimeter of the International Large Detector for the International Linear Collider. The prototype was exposed to beams of muons, electrons and pions of different energies at the CERN Super Proton Synchrotron. To be able to study the performance of such a calorimeter in future experiments it is important to ensure reliable simulation of its response. In this paper we present our prototype simulation performed with GEANT4 and the digitization procedure achieved with an algorithm called SimDigital. A detailed description of this algorithm is given and the methods to determinate its parameters using muon tracks and electromagnetic showers are explained. The comparison with hadronic shower data shows a good agreement up to 50 GeV. Discrepancies are observed at higher energies. The reasons for these differences are investigated.
  • Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter (1306.3037)

    C.Adloff, J.Blaha, J.-J.Blaising, C.Drancourt, A.Espargilière, R. Gaglione, N.Geffroy, Y.Karyotakis, J.Prast, G.Vouters, K. Francis, J.Repond, J.Schlereth, J.Smith, L.Xia, E.Baldolemar, J. Li, S. T.Park, M.Sosebee, A.P.White, J.Yu, T.Buanes, G.Eigen, Y.Mikami, N.K.Watson, G.Mavromanolakis, M.A. Thomson, D.R.Ward, W.Yan, D.Benchekroun, A.Hoummada, Y.Khoulaki, J.Apostolakis, A.Dotti, G. Folger, V. Ivantchenko, V.Uzhinskiy, M.Benyamna, C.Cârloganu, F. Fehr, P.Gay, S.Manen, L.Royer, G.C.Blazey, A.Dyshkant, J. G.R. Lima, V. Zutshi, J. -Y.Hostachy, L.Morin, U.Cornett, D.David, G. Falley, K.Gadow, P.Göttlicher, C.Günter, B.Hermberg, S.Karstensen, F.Krivan, A. -I. Lucaci-Timoce, S. Lu, B. Lutz, S.Morozov, V.Morgunov, M.Reinecke, F.Sefkow, P.Smirnov, M. Terwort, A.Vargas-Trevino, N. Feege, E. Garutti, I.Marchesinik, M.Ramilli, P.Eckert, T.Harion, A.Kaplan, H. -Ch.Schultz-Coulon, W.Shen, R.Stamen, B.Bilki, E.Norbeck, Y.Onel, G.W.Wilson, K.Kawagoe, P.D.Dauncey, A. -M.Magnan, V.Bartsch, M.Wing, F.Salvatore, E.Calvo Alamillo, M.-C. Fouz, J.Puerta-Pelayo, B.Bobchenko, M.Chadeeva, M.Danilov, A.Epifantsev, O.Markin, R.Mizuk, E.Novikov, V.Popov, V.Rusinov, E. Tarkovsky, N.Kirikova, V.Kozlov, P.Smirnov, Y. Soloviev, P.Buzhan, A. Ilyin, V.Kantserov, V.Kaplin, A.Karakash, E.Popova, V. Tikhomirov, C.Kiesling, K.Seidel, F.Simon, C.Soldner, M.Szalay, M. Tesar, L.Weuste, M.S.Amjad, J.Bonis, S.Callier, S. Conforti di Lorenzo, P.Cornebise, Ph.Doublet, F.Dulucq, J. Fleury, T. Frisson, N. van der Kolk, H. Li, G.Martin-Chassard, F.Richard, Ch. de la Taille, R.Pöschl, L.Raux, J.Rouëné, N.Seguin-Moreau, M.Anduze, V.Boudry, J-C.Brient, D. Jeans, P.Mora de Freitas, G.Musat, M.Reinhard, M.Ruan, H.Videau, B.Bulanek, J. Zacek, J.Cvach, P.Gallus, M.Havranek, M. Janata, J.Kvasnicka, D. Lednicky, M.Marcisovsky, I.Polak, J.Popule, L. Tomasek, M. Tomasek, P.Ruzicka, P.Sicho, J.Smolik, V.Vrba, J. Zalesak, B.Belhorma, H.Ghazlane, T. Takeshita, S.Uozumi, M. Götze, O. Hartbrich, J.Sauer, S.Weber, C. Zeitnitz
    June 15, 2014 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.