• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Photoproduction of $\omega$ mesons on nuclei near the production threshold (1008.4520)

    M. Nanova, J. Weil, S. Friedrich, V. Metag, U. Mosel, G. Anton, J.C.S. Bacelar, O. Bartholomy, D. Bayadilov, Y.A. Beloglazov, R. Bogendörfer, R. Castelijns, V. Crede, H. Dutz, A. Ehmanns, D. Elsner, K. Essig, R. Ewald, I. Fabry, M. Fuchs, Ch. Funke, R. Gothe, R. Gregor, A.B. Gridnev, E. Gutz, S. Höffgen, P. Hoffmeister, I. Horn, J. Hössl, I. Jaegle, J. Junkersfeld, H. Kalinowsky, Frank Klein, Friedrich Klein, E. Klempt, M. Konrad, B. Kopf, M. Kotulla, B. Krusche, J. Langheinrich, H. Löhner, I.V. Lopatin, J. Lotz, S. Lugert, D. Menze, T. Mertens, J.G. Messchendorp, C. Morales, R. Novotny, M. Ostrick, L.M. Pant, H. van Pee, M. Pfeiffer, A. Roy, A. Radkov, S. Schadmand, Ch. Schmidt, H. Schmieden, B. Schoch, S. Shende, G. Suft, A. Süle, V.V. Sumachev, T. Szczepanek, U. Thoma, D. Trnka, R. Varma, D. Walther, Ch. Weinheimer, Ch. Wendel
    Feb. 17, 2011 nucl-ex
    ... ... ... ... ... ...
    The photoproduction of $\omega$ mesons on LH_2, C and Nb has been studied for incident photon energies from 900 to 1300 MeV using the CB/TAPS detector at ELSA. The $\omega$ line shape does not show any significant difference between the LH_2 and the Nb targets. The data are compared with results of transport calculations that predict a sensitivity of the $\omega$ line shape to in-medium modifications near the production threshold on a free nucleon of $E_{\gamma}^{lab}$ = 1109 MeV.}
  • Ion source for tests of ion behavior in the KATRIN beam line (1008.3342)

    S. Lukic, B. Bornschein, G. Drexlin, F. Glück, O. Kazachenko, M. Schöppner, Ch. Weinheimer, M. C. R. Zoll
    Jan. 21, 2011 physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    An electron-impact ion source based on photoelectron emission was developed for ionization of gases at pressures below 1e-4 mbar in an axial magnetic field in the order of 5 T. The ion source applies only DC fields, which makes it suitable for use in the presence of equipment sensitive to radio-frequency (RF) fields. The ion source was succesfully tested under varying conditions regarding pressure, magnetic field and magnetic-field gradient, and the results were studied with the help of simulations. The processes in the ion source are well understood and possibilities for further optimization of generated ion currents are clarified.
  • Calibration of the ISOLDE acceleration voltage using a high-precision voltage divider and applying collinear fast beam laser spectroscopy (1101.2536)

    A. Krieger, Ch. Geppert, R. Catherall, F. Hochschulz, J. Krämer, R. Neugart, S. Rosendahl, J. Schipper, E. Siesling, Ch. Weinheimer, D. T. Yordanov, W. Nörtershäuser
    Jan. 13, 2011 physics.atom-ph
    ... ... ... ... ... ...
    A high-voltage divider with accuracy at the ppm level and collinear laser spectroscopy were used to calibrate the highvoltage installation at the radioactive ion beam facility ISOLDE at CERN. The accurate knowledge of this voltage is particularly important for collinear laser spectroscopy measurements. Beam velocity measurements using frequencycomb based collinear laser spectroscopy agree with the new calibration. Applying this, one obtains consistent results for isotope shifts of stable magnesium isotopes measured using collinear spectroscopy and laser spectroscopy on laser-cooled ions in a trap. The long-term stability and the transient behavior during recovery from a voltage dropout were investigated for the different power supplies currently applied at ISOLDE.
  • Prototype of an angular-selective photoelectron calibration source for the KATRIN experiment (1011.6365)

    K. Valerius, H. Hein, H. Baumeister, M. Beck, K. Bokeloh, J. Bonn, F. Glück, H.-W. Ortjohann, B. Ostrick, M. Zbořil, Ch. Weinheimer
    Nov. 29, 2010 physics.ins-det
    ... ... ... ... ... ...
    The method of direct neutrino mass determination based on the kinematics of tritium beta decay, which is adopted by the KATRIN experiment, makes use of a large, high-resolution electrostatic spectrometer with magnetic adiabatic collimation. In order to target a sensitivity on the neutrino mass of 0.2 eV/c^2, a detailed understanding of the electromagnetic properties of the electron spectrometer is essential, requiring comprehensive calibration measurements with dedicated electron sources. In this paper we report on a prototype of a photoelectron source providing a narrow energy spread and angular selectivity. Both are key properties for the characterisation of the spectrometer. The angular selectivity is achieved by applying non-parallel strong electric and magnetic fields: Directly after being created, photoelectrons are accelerated rapidly and non-adiabatically by a strong electric field before adiabatic magnetic guiding takes over.
  • In-medium $\omega$ mass from the $\gamma + Nb \to \pi^{0}\gamma + X$ reaction (1005.5694)

    The The CBELSA/TAPS Collaboration: M. Nanova, V.Metag, G. Anton, J.C.S. Bacelar, O. Bartholomy, D. Bayadilov, Y.A.Beloglazov, R.Bogendörfer, R. Castelijns, V. Crede, H. Dutz, A. Ehmanns, D. Elsner, K. Essig, R. Ewald, I. Fabry, M. Fuchs, Ch. Funke, R. Gothe, R. Gregor, A.B. Gridnev, E. Gutz, S. Höffgen, P. Hoffmeister, I. Horn, J. Hössl, I. Jaegle, J. Junkersfeld, H. Kalinowsky, Frank Klein, Friedrich Klein, E. Klempt, M. Konrad, B. Kopf, M. Kotulla, B. Krusche, J. Langheinrich, H. Löhner, I.V. Lopatin, J. Lotz, S. Lugert, D. Menze, T. Mertens, J.G. Messchendorp, C. Morales, R. Novotny, M. Ostrick, L.M. Pant, H. van Pee, M. Pfeiffer, A. Roy, A. Radkov, S. Schadmand, Ch. Schmidt, H. Schmieden, B. Schoch, S. Shende, G. Suft, A. Süle, V. V. Sumachev, T. Szczepanek, U. Thoma, D. Trnka, R. Varma, D. Walther, Ch. Weinheimer, Ch. Wendel
    Sept. 22, 2010 nucl-ex
    ... ... ... ... ... ...
    Data on the photoproduction of $\omega$ mesons on nuclei have been re-analyzed in a search for in-medium modifications. The data were taken with the Crystal Barrel(CB)/TAPS detector system at the ELSA accelerator facility in Bonn. First results from the analysis of the data set were published by D. Trnka et al. in Phys. Rev. Lett 94 (2005) 192303 \cite{david}, claiming a lowering of the $\omega$ mass in the nuclear medium by 14$%$ at normal nuclear matter density. The extracted $\omega$ line shape was found to be sensitive to the background subtraction. For this reason a re-analysis of the same data set has been initiated and a new method has been developed to reduce the background and to determine the shape and absolute magnitude of the background directly from the data. Details of the re-analysis and of the background determination are described. The $\omega$ signal on the $Nb$ target, extracted in the re-analysis, does not show a deviation from the corresponding line shape on a $LH_2$ target, measured as reference. The earlier claim of an in-medium mass shift is thus not confirmed. The sensitivity of the $\omega$ line shape to different in-medium modification scenarios is discussed.
  • First detection and energy measurement of recoil ions following beta decay in a Penning trap with the WITCH experiment (1008.0207)

    M. Beck, S. Coeck, V.Yu. Kozlov, M. Breitenfeld, P. Delahaye, P. Friedag, M. Herbane, A. Herlert, I.S. Kraev, J. Mader, M. Tandecki, S. Van Gorp, F. Wauters, Ch. Weinheimer, F. Wenander, N. Severijns
    Aug. 1, 2010 nucl-ex
    ... ... ... ... ... ...
    The WITCH experiment (Weak Interaction Trap for CHarged particles) will search for exotic interactions by investigating the beta-neutrino angular correlation via the measurement of the recoil energy spectrum after beta decay. As a first step the recoil ions from the beta-minus decay of 124In stored in a Penning trap have been detected. The evidence for the detection of recoil ions is shown and the properties of the ion cloud that forms the radioactive source for the experiment in the Penning trap are presented.
  • Feasibility of photoelectron sources for testing the energy scale stablity of the KATRIN beta-ray spectrometer (1003.3758)

    O. Dragoun, A. Spalek, J. Kaspar, J. Bonn, A. Kovalik, E. W. Otten, D. Venos, Ch. Weinheimer
    March 19, 2010 nucl-ex
    Photoabsorption of nuclear gamma-rays in thin metallic convertors was examined with the aim to produce monoenergetic photoelectrons of kinetic energy around 18.6 keV and natural width of about 1 eV. Calculations were carried out for commercial photon sources of 241Am (1.1 GBq) and 119mSn (0.5 GBq) irradiating Co and Ti convertors. Photoelectrons ejected by 241Am gamma- and X-rays from Co convertors of various thickness were measured with two electrostatic spectrometers.
  • Photoproduction of meson pairs: First measurement of the polarization observable I^s (0912.2632)

    E. Gutz, V. Sokhoyan, H. van Pee, A.V. Anisovich, J.C.S. Bacelar, B. Bantes, O. Bartholomy, D. Bayadilov, R. Beck, Yu. Beloglazov, R. Castelijns, V. Crede, H. Dutz, D. Elsner, R. Ewald, F. Frommberger, M. Fuchs, Ch. Funke, R. Gregor, A. Gridnev, W. Hillert, Ph. Hoffmeister, I. Horn, I. Jaegle, J. Junkersfeld, H. Kalinowsky, S. Kammer, V. Kleber, Frank Klein, Friedrich Klein, E. Klempt, M. Kotulla, B. Krusche, M. Lang, H. Loehner, I. Lopatin, S. Lugert, D. Menze, T. Mertens, J.G. Messchendorp, V. Metag, M. Nanova, V. Nikonov, D. Novinski, R. Novotny, M. Ostrick, L. Pant, M. Pfeiffer, D. Piontek, W. Roberts, A. Roy, A. Sarantsev, S. Schadmand, Ch. Schmidt, H. Schmieden, B. Schoch, S. Shende, A. Suele, V. Sumachev, T. Szczepanek, A. Thiel, U. Thoma, D. Trnka, R. Varma, D. Walther, Ch. Weinheimer, Ch. Wendel
    Feb. 26, 2010 nucl-ex
    ... ... ... ... ... ...
    The polarization observable I^s, a feature exclusive to the acoplanar kinematics of multi-meson final states produced via linearly polarized photons, has been measured for the first time. Results for the reaction g p -> p pi0 eta are presented for incoming photon energies between 970 MeV and 1650 MeV along with the beam asymmetry I^c. The comparably large asymmetries demonstrate a high sensitivity of I^s to the dynamics of the reaction. Fits using Bonn-Gatchina partial wave analysis demonstrate that the new polarization observables carry significant information on the contributing partial waves.
  • Contactless 2-dimensional laser sensor for 3-dimensional wire position and tension measurements (0907.5490)

    Matthias Prall, V. Hannen, R. Joehren, H.W. Ortjohann, M. Reinhardt, Ch. Weinheimer
    Feb. 3, 2010 physics.ins-det
    ... ... ... ... ... ...
    We have developed a contact-free 2-dimensional laser sensor with which the position of wires can be measured in 3 dimensions with an accuracy of better than 10 micrometer and with which the tension of the wires can be determined with an accuracy of 0.04 N. These measurements can be made from a distance of 15 cm. The sensor consists of commercially available laser pointers, lenses, color filters and photodiodes. In our application we have used this laser sensor together with an automated 3 dimensional coordinate table. For a single position measurement, the laser sensor is moved by the 3-dimensional coordinate table in a plane and determines the coordinates at which the wires intersect with this plane. The position of the plane itself (the third coordinate) is given by the third axis of the measurement table which is perpendicular to this plane. The control and readout of the table and the readout of the laser sensor were realized with LabVIEW. The precision of the position measurement in the plane was determined with wires of 0.2 mm and 0.3 mm diameter. We use the sensor for the quality assurance of the wire electrode modules for the KATRIN neutrino mass experiment. We expect that the precision is at least comparable or better if the wires are thinner. Such a device could be well suited for the measurement of wire chamber geometries even with more than one wire layer.
  • Precision high voltage divider for the KATRIN experiment (0908.1523)

    Th. Thümmler, R. Marx, Ch. Weinheimer
    Aug. 11, 2009 physics.ins-det
    ... ... ... ... ... ...
    The Karlsruhe Tritium Neutrino Experiment (KATRIN) aims to determine the absolute mass of the electron antineutrino from a precise measurement of the tritium beta-spectrum near its endpoint at 18.6 keV with a sensitivity of 0.2 eV. KATRIN uses an electrostatic retardation spectrometer of MAC-E filter type for which it is crucial to monitor high voltages of up to 35 kV with a precision and long-term stability at the ppm level. Since devices capable of this precision are not commercially available, a new high voltage divider for direct voltages of up to 35 kV has been designed, following the new concept of the standard divider for direct voltages of up to 100 kV developed at the Physikalisch-Technische Bundesanstalt (PTB). The electrical and mechanical design of the divider, the screening procedure for the selection of the precision resistors, and the results of the investigation and calibration at PTB are reported here. During the latter, uncertainties at the low ppm level have been deduced for the new divider, thus qualifying it for the precision measurements of the KATRIN experiment.
  • A UV LED-based fast-pulsed photoelectron source for time-of-flight studies (0902.2305)

    K. Valerius, M. Beck, H. Arlinghaus, J. Bonn, V. M. Hannen, H. Hein, B. Ostrick, S. Streubel, Ch. Weinheimer, M. Zboril
    June 17, 2009 physics.ins-det
    ... ... ... ... ... ...
    We report on spectroscopy and time-of-flight measurements using an 18 keV fast-pulsed photoelectron source of adjustable intensity, ranging from single photoelectrons per pulse to 5 photoelectrons per microsecond at pulse repetition rates of up to 10 kHz. Short pulses between 40 ns and 40 microseconds in length were produced by switching light emitting diodes with central output wavelengths of 265 nm and 257 nm, in the deep ultraviolet (or UV-C) regime, at kHz frequencies. Such photoelectron sources can be useful calibration devices for testing the properties of high-resolution electrostatic spectrometers, like the ones used in current neutrino mass searches.
  • Long term stability of the energy of conversion electrons emitted from solid 83Rb/83mKr source (0902.0291)

    D. Venos, J. Kaspar, M. Zboril, O. Dragoun, J. Bonn, A. Kovalik, O. Lebeda, M. Rysavy, K. Schlosser, A. Spalek, Ch. Weinheimer
    Feb. 2, 2009 physics.ins-det
    ... ... ... ... ... ...
    The mono-energetic conversion electrons from the decay of 83mKr represent a unique tool for the energy calibration, energy scale monitoring and systematic studies of the tritium beta spectrum measurement in the neutrino mass experiment KATRIN. For this reason, the long term stability of energy of the 7.5 keV and 17.8 keV conversion electrons populated in the decay of solid 83Rb/83mKr vacuum evaporated sources was examined by means of two electron spectrometers.
  • The WITCH experiment: Acquiring the first recoil ion spectrum (0807.3421)

    V.Yu. Kozlov, M. Beck, S. Coeck, P. Delahaye, P. Friedag, M. Herbane, A. Herlert, I.S. Kraev, M. Tandecki, S. Van Gorp, F. Wauters, Ch. Weinheimer, F. Wenander, D. Zakoucky, N. Severijns
    July 22, 2008 nucl-ex
    ... ... ... ... ... ...
    The standard model of the electroweak interaction describes beta-decay in the well-known V-A form. Nevertheless, the most general Hamiltonian of a beta-decay includes also other possible interaction types, e.g. scalar (S) and tensor (T) contributions, which are not fully ruled out yet experimentally. The WITCH experiment aims to study a possible admixture of these exotic interaction types in nuclear beta-decay by a precise measurement of the shape of the recoil ion energy spectrum. The experimental set-up couples a double Penning trap system and a retardation spectrometer. The set-up is installed in ISOLDE/CERN and was recently shown to be fully operational. The current status of the experiment is presented together with the data acquired during the 2006 campaign, showing the first recoil ion energy spectrum obtained. The data taking procedure and corresponding data acquisition system are described in more detail. Several further technical improvements are briefly reviewed.
  • Modification of the $\omega$-Meson Lifetime in Nuclear Matter (0802.0989)

    M. Kotulla, D. Trnka, P. Mühlich, G. Anton, J. C. S. Bacelar, O. Bartholomy, D. Bayadilov, Y. A. Beloglazov, R. Bogendörfer, R. Castelijns, V. Crede, H. Dutz, A. Ehmanns, D. Elsner, R. Ewald, I. Fabry, M. Fuchs, K. Essig, Ch. Funke, R. Gothe, R. Gregor, A. B. Gridnev, E. Gutz, S. Höffgen, P. Hoffmeister, I. Horn, J. Hössl, I. Jaegle, J. Junkersfeld, H. Kalinowsky, Frank Klein, Fritz Klein, E. Klempt, M. Konrad, B. Kopf, B. Krusche, J. Langheinrich, H. Löhner, I.V. Lopatin, J. Lotz, S. Lugert, D. Menze, J. G. Messchendorp, T. Mertens, V. Metag, U. Mosel, M. Nanova, R. Novotny, M. Ostrick, L. M. Pant, H. van Pee, M. Pfeiffer, A. Roy, A. Radkov, S. Schadmand, Ch. Schmidt, H. Schmieden, B. Schoch, S. Shende, G. Suft, V. V. Sumachev, T. Szczepanek, A. Süle, U. Thoma, R. Varma, D. Walther, Ch. Weinheimer, Ch. Wendel
    Feb. 7, 2008 hep-ph, nucl-ex, nucl-th
    ... ... ... ... ... ...
    The photo production of $\omega$ mesons on the nuclei C, Ca, Nb and Pb has been measured using the Crystal Barrel/TAPS detector at the ELSA tagged photon facility in Bonn. The dependence of the $\omega$ meson cross section on the nuclear mass number has been compared with three different types of models, a Glauber analysis, a BUU analysis of the Giessen theory group and a calculation by the Valencia theory group. In all three cases, the inelastic $\omega$ width is found to be $130-150 \rm{MeV/c^2}$ at normal nuclear matter density for an average 3-momentum of 1.1 GeV/c. In the restframe of the $\omega$ meson, this inelastic $\omega$ width corresponds to a reduction of the $\omega$ lifetime by a factor $\approx 30$. For the first time, the momentum dependent $\omega$N cross section has been extracted from the experiment and is in the range of 70 mb.
  • Final Results from phase II of the Mainz Neutrino Mass Search in Tritium $\beta$ Decay (hep-ex/0412056)

    Ch. Kraus, B. Bornschein, L. Bornschein, J. Bonn, B. Flatt, A. Kovalik, B. Ostrick, E.W. Otten, J.P. Schall, Th. Thümmler, Ch. Weinheimer
    Jan. 6, 2005 hep-ex
    The paper reports on the improved Mainz experiment on tritum $\beta$ spectroscopy which yields a 10 times' higher signal to background ratio than before. The main experimental effects and systematic uncertainties have been investigated in side experiments and possible error sources have been eliminated. Extensive data taking took place in the years 1997 to 2001. A residual analysis of the data sets yields for the square of the electron antineutrino mass the final result of $m^2(\nu_e)=(-0.6 \pm 2.2_{\rm{stat}} \pm 2.1_{\rm{syst}})$ eV$^2$/c$^4$. We derive an upper limit of $m(\nu_e)\leq 2.3$ eV/c$^2$ at 95% confidence level for the mass itself.