-
A joint measurement is presented of the branching fractions
$B^0_s\to\mu^+\mu^-$ and $B^0\to\mu^+\mu^-$ in proton-proton collisions at the
LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at
a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis
produces the first observation of the $B^0_s\to\mu^+\mu^-$ decay, with a
statistical significance exceeding six standard deviations, and the best
measurement of its branching fraction so far. Furthermore, evidence for the
$B^0\to\mu^+\mu^-$ decay is obtained with a statistical significance of three
standard deviations. The branching fraction measurements are statistically
compatible with SM predictions and impose stringent constraints on several
theories beyond the SM.
-
The First G-APD Cherenkov telescope (FACT) is the first telescope using
silicon photon detectors (G-APD aka. SiPM). It is built on the mount of the
HEGRA CT3 telescope, still located at the Observatorio del Roque de los
Muchachos, and it is successfully in operation since Oct. 2011. The use of
Silicon devices promises a higher photon detection efficiency, more robustness
and higher precision than photo-multiplier tubes. The FACT collaboration is
investigating with which precision these devices can be operated on the
long-term. Currently, the telescope is successfully operated from remote and
robotic operation is under development. During the past months of operation,
the foreseen monitoring program of the brightest known TeV blazars has been
carried out, and first physics results have been obtained including a strong
flare of Mrk501. An instantaneous flare alert system is already in a testing
phase. This presentation will give an overview of the project and summarize its
goals, status and first results.
-
The First G-APD Cherenkov Telescope (FACT) became operational at La Palma in
October 2011. Since summer 2012, due to very smooth and stable operation, it is
the first telescope of its kind that is routinely operated from remote, without
the need for a data-taking crew on site. In addition, many standard tasks of
operation are executed automatically without the need for manual interaction.
Based on the experience gained so far, some alterations to improve the safety
of the system are under development to allow robotic operation in the future.
We present the setup and precautions used to implement remote operations and
the experience gained so far, as well as the work towards robotic operation.
-
Geiger-mode Avalanche Photodiodes (G-APD) bear the potential to significantly
improve the sensitivity of Imaging Air Cherenkov Telescopes (IACT). We are
currently building the First G-APD Cherenkov Telescope (FACT) by refurbishing
an old IACT with a mirror area of 9.5 square meters and construct a new, fine
pixelized camera using novel G-APDs. The main goal is to evaluate the
performance of a complete system by observing very high energy gamma-rays from
the Crab Nebula. This is an important field test to check the feasibility of
G-APD-based cameras to replace at some time the PMT-based cameras of planned
future IACTs like AGIS and CTA. In this article, we present the basic design of
such a camera as well as some important details to be taken into account.
-
Geiger-mode avalanche photodiodes (G-APD) are promising new sensors for light
detection in atmospheric Cherenkov telescopes. In this paper, the design and
commissioning of a 36-pixel G-APD prototype camera is presented. The data
acquisition is based on the Domino Ring Sampling (DRS2) chip. A sub-nanosecond
time resolution has been achieved. Cosmic-ray induced air showers have been
recorded using an imaging mirror setup, in a self-triggered mode. This is the
first time that such measurements have been carried out with a complete G-APD
camera.
-
A Lead Tungstate crystal produced for the electromagnetic calorimeter of the
CMS experiment at the LHC was cut into three equal-length sections. The central
one was irradiated with 290 MeV/c positive pions up to a fluence of (5.67 +-
0.46)x10^13 /cm^2, while the other two were exposed to a 24 GeV/c proton
fluence of (1.17 +- 0.11) x 10^13/ cm^2. The damage recovery in these crystals,
stored in the dark at room temperature, has been followed over two years. The
comparison of the radiation-induced changes in light transmission for these
crystals shows that damage is proportional to the star densities produced by
the irradiation.
-
We describe the design, construction and performance of the PIBETA detector
built for the precise measurement of the branching ratio of pion beta decay,
pi+ -> pi0 e+ nu, at the Paul Scherrer Institute. The central part of the
detector is a 240-module spherical pure CsI calorimeter covering 3*pi sr solid
angle. The calorimeter is supplemented with an active collimator/beam degrader
system, an active segmented plastic target, a pair of low-mass cylindrical wire
chambers and a 20-element cylindrical plastic scintillator hodoscope. The whole
detector system is housed inside a temperature-controlled lead brick enclosure
which in turn is lined with cosmic muon plastic veto counters. Commissioning
and calibration data were taken during two three-month beam periods in
1999/2000 with pi+ stopping rates between 1.3*E3 pi+/s and 1.3*E6 pi+/s. We
examine the timing, energy and angular detector resolution for photons,
positrons and protons in the energy range of 5-150 MeV, as well as the response
of the detector to cosmic muons. We illustrate the detector signatures for the
assorted rare pion and muon decays and their associated backgrounds.
-
We have measured scintillation properties of pure CsI crystals used in the
shower calorimeter built for a precise determination of the pi+ -> pi0 e+ nu
decay rate at the Paul Scherrer Institute (PSI). All 240 individual crystals
painted with a special wavelength-shifting solution were examined in a
custom-build detection apparatus (RASTA=radioactive source tomography
apparatus) that uses a 137Cs radioactive gamma source, cosmic muons and a light
emitting diode as complementary probes of the scintillator light response. We
have extracted the total light output, axial light collection nonuniformities
and timing responses of the individual CsI crystals. These results predict
improved performance of the 3 pi sr PIBETA calorimeter due to the painted
lateral surfaces of 240 CsI crystals. The wavelength-shifting paint treatment
did not affect appreciably the total light output and timing resolution of our
crystal sample. The predicted energy resolution for positrons and photons in
the energy range of 10-100 MeV was nevertheless improved due to the more
favorable axial light collection probability variation. We have compared
simulated calorimeter ADC spectra due to 70 MeV positrons and photons with a
Monte Carlo calculation of an ideal detector light response.