The KATRIN experiment aims to determine the effective electron neutrino mass
with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision
measurement of the shape of the tritium \textbeta-spectrum in the endpoint
region. The energy analysis of the decay electrons is achieved by a MAC-E
filter spectrometer. A common background source in this setup is the decay of
short-lived isotopes, such as $\textsuperscript{219}$Rn and
$\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive
countermeasures have been implemented and tested at the KATRIN main
spectrometer. One of these is the magnetic pulse method, which employs the
existing air coil system to reduce the magnetic guiding field in the
spectrometer on a short timescale in order to remove low- and high-energy
stored electrons. Here we describe the working principle of this method and
present results from commissioning measurements at the main spectrometer.
Simulations with the particle-tracking software Kassiopeia were carried out to
gain a detailed understanding of the electron storage conditions and removal
processes.
-
We report on a precise measurement of double-polarization asymmetries in
electron-induced breakup of $^3\mathrm{He}$ proceeding to $\mathrm{pd}$ and
$\mathrm{ppn}$ final states, performed in quasi-elastic kinematics at $Q^2 =
0.25\,(\mathrm{GeV}/c)^2$ for missing momenta up to $250\,\mathrm{MeV}/c$.
These observables represent highly sensitive tools to investigate the
electromagnetic and spin structure of $^3\mathrm{He}$ and the relative
importance of two- and three-body effects involved in the breakup reaction
dynamics. The measured asymmetries cannot be satisfactorily reproduced by
state-of-the-art calculations of $^3\mathrm{He}$ unless their three-body
segment is adjusted, indicating that the spin-dependent part of the nuclear
interaction governing the three-body breakup process is much smaller than
previously thought.
-
The neutrino mass experiment KATRIN requires a stability of 3 ppm for the
retarding potential at -18.6 kV of the main spectrometer. To monitor the
stability, two custom-made ultra-precise high-voltage dividers were developed
and built in cooperation with the German national metrology institute
Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute
calibration of the voltage dividers required bringing the equipment to the
specialised metrology laboratory. Here we present a new method based on
measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron
lines with the KATRIN setup, which was demonstrated during KATRIN's
commissioning measurements in July 2017. The measured scale factor
$M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last
PTB calibration four years ago. This result demonstrates the utility of the
calibration method, as well as the long-term stability of the voltage divider.
-
The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to
probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90%
confidence level), via a precise measurement of the endpoint spectrum of
tritium beta decay. This work documents several KATRIN commissioning
milestones: the complete assembly of the experimental beamline, the successful
transmission of electrons from three sources through the beamline to the
primary detector, and tests of ion transport and retention. In the First Light
commissioning campaign of Autumn 2016, photoelectrons were generated at the
rear wall and ions were created by a dedicated ion source attached to the rear
section; in July 2017, gaseous Kr-83m was injected into the KATRIN source
section, and a condensed Kr-83m source was deployed in the transport section.
In this paper we describe the technical details of the apparatus and the
configuration for each measurement, and give first results on source and system
performance. We have successfully achieved transmission from all four sources,
established system stability, and characterized many aspects of the apparatus.
-
We report on the results of the E06-014 experiment performed at Jefferson Lab
in Hall A, where a precision measurement of the twist-3 matrix element $d_2$ of
the neutron ($d_{2}^{n}$) was conducted. This quantity represents the average
color Lorentz force a struck quark experiences in a deep inelastic electron
scattering event off a neutron due to its interaction with the hadronizing
remnants. This color force was determined from a linear combination of the
third moments of the spin structure functions $g_1$ and $g_2$ on $^{3}$He after
nuclear corrections had been applied to these moments. The kinematics included
two average $Q^{2}$ bins of $3.2$ GeV$^{2}$ and $4.3$ GeV$^{2}$, and
Bjorken-$x$ $0.25 \leq x \leq 0.90$ covering the DIS and resonance regions. We
found $d_2^n$ to be small and negative for $<Q^{2}> = 3.2$ GeV$^{2}$, and
smaller for $<Q^{2}> = 4.3$ GeV$^{2}$, consistent with a lattice QCD
calculation. The twist-4 matrix element $f_{2}^{n}$ was extracted by combining
our $d_{2}^{n}$ with the world data on $\Gamma_{1}^{n} = \int_{0}^{1} g_{1}^{n}
dx$. We found $f_{2}^{n}$ to be roughly an order of magnitude larger than
$d_{2}^{n}$. Utilizing the extracted $d_{2}^{n}$ and $f_{2}^{n}$ data, we
separated the color force into its electric and magnetic components,
$F_{E}^{y,n}$ and $F_{B}^{y,n}$, and found them to be equal and opposite in
magnitude, in agreement with instanton model predictions but not with those
from QCD sum rules. Additionally, we have extracted the neutron virtual
photon-nucleon asymmetry $A_{1}^{n}$, the structure function ratio
$g_{1}^{n}/F_{1}^{n}$, and the quark ratios $(\Delta u + \Delta \bar{u})/(u +
\bar{u})$ and $(\Delta d + \Delta \bar{d})/(d + \bar{d})$. These results were
found to be consistent with DIS world data and with the prediction of the
constituent quark model but at odds with those of perturbative QCD at large
$x$.
-
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN)
experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout
electronics, two superconducting solenoid magnets, an ultra high-vacuum system,
a high-vacuum system, calibration and monitoring devices, a scintillating veto,
and a custom data-acquisition system. It is designed to detect the low-energy
electrons selected by the KATRIN main spectrometer. We describe the system and
summarize its performance after its final installation.
-
We have performed precision measurements of the double-spin virtual-photon
asymmetry $A_1$ on the neutron in the deep inelastic scattering regime, using
an open-geometry, large-acceptance spectrometer. Our data cover a wide
kinematic range $0.277 \leq x \leq 0.548$ at an average $Q^2$ value of
3.078~(GeV/c)$^2$, doubling the available high-precision neutron data in this
$x$ range. We have combined our results with world data on proton targets to
extract the ratio of polarized-to-unpolarized parton distribution functions for
up quarks and for down quarks in the same kinematic range. Our data are
consistent with a previous observation of an $A_1^n$ zero crossing near
$x=0.5$. We find no evidence of a transition to a positive slope in $(\Delta d
+ \Delta \bar{d})/(d + \bar{d})$ up to $x=0.548$.
-
Double-spin asymmetries and absolute cross sections were measured at large
Bjorken $x$ (0.25 $ \le x \le $ 0.90), in both the deep-inelastic and resonance
regions, by scattering longitudinally polarized electrons at beam energies of
4.7 and 5.9 GeV from a transversely and longitudinally polarized $^3$He target.
In this dedicated experiment, the spin structure function $g_2$ on $^3$He was
determined with precision at large $x$, and the neutron twist-three matrix
element $d_2^n$ was measured at $\left< Q^2\right>$ of 3.21 and 4.32
GeV$^2$/$c^2$, with an absolute precision of about $10^{-5}$. Our results are
found to be in agreement with lattice QCD calculations and resolve the
disagreement found with previous data at $\left< Q^2\right> =$ 5 GeV$^2$/$c^2$.
Combining $d_2^n$ and a newly extracted twist-four matrix element, $f_2^n$, the
average neutron color electric and magnetic forces were extracted and found to
be of opposite sign and about 30 MeV/fm in magnitude.
-
Semiconductor detectors in general have a dead layer at their surfaces that
is either a result of natural or induced passivation, or is formed during the
process of making a contact. Charged particles passing through this region
produce ionization that is incompletely collected and recorded, which leads to
departures from the ideal in both energy deposition and resolution. The silicon
\textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a
dead layer. We have constructed a detailed Monte Carlo model for the passage of
electrons from vacuum into a silicon detector, and compared the measured energy
spectra to the predicted ones for a range of energies from 12 to 20 keV. The
comparison provides experimental evidence that a substantial fraction of the
ionization produced in the "dead" layer evidently escapes by diffusion, with
46% being collected in the depletion zone and the balance being neutralized at
the contact or by bulk recombination. The most elementary model of a thinner
dead layer from which no charge is collected is strongly disfavored.
-
We have modeled, tested, and installed a large, cerium-activated Gd2SiO5
crystal scintillator for use as a detector of gamma rays. We present the
measured detector response to two types of incident photons: nearly
monochromatic photons up to 40 MeV, and photons from a continuous Compton
backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to
determine the analyzing power of the Compton polarimeter in Hall A of Jefferson
Lab, reproduce the measured spectra well.