  • Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment (1805.01163)

    KATRIN Collaboration: M. Arenz, W.-J. Baek, S. Bauer, M. Beck, A. Beglarian, J. Behrens, R. Berendes, T. Bergmann, A. Berlev, U. Besserer, K. Blaum, T. Bode, B. Bornschein, L. Bornschein, T. Brunst, W. Buglak, N. Buzinsky, S. Chilingaryan, W. Q. Choi, M. Deffert, P. J. Doe, O. Dragoun, G. Drexlin, S. Dyba, F. Edzards, K. Eitel, E. Ellinger, R. Engel, S. Enomoto, M. Erhard, D. Eversheim, M. Fedkevych, J. A. Formaggio, F. M. Fränkle, G. B. Franklin, F. Friedel, A. Fulst, D. Furse, W. Gil, F. Glück, A. Gonzalez Urena, S. Grohmann, R. Grössle, R. Gumbsheimer, M. Hackenjos, V. Hannen, F. Harms, N. Haußmann, F. Heizmann, K. Helbing, W. Herz, S. Hickford, D. Hilk, M. A. Howe, A. Huber, A. Jansen, J. Kellerer, N. Kernert, L. Kippenbrock, M. Kleesiek, M. Klein, A. Kopmann, M. Korzeczek, A. Kovalík, B. Krasch, M. Kraus, L. Kuckert, T. Lasserre, O. Lebeda, J. Letnev, A. Lokhov, M. Machatschek, A. Marsteller, E. L. Martin, S. Mertens, S. Mirz, B. Monreal, H. Neumann, S. Niemes, A. Off, A. Osipowicz, E. Otten, D. S. Parno, A. Pollithy, A. W. P. Poon, F. Priester, P. C.-O. Ranitzsch, O. Rest, R. G. H. Robertson, F. Roccati, C. Rodenbeck, M. Röllig, C. Röttele, M. Ryšavý, R. Sack, A. Saenz, L. Schimpf, K. Schlösser, M. Schlösser, K. Schönung, M. Schrank, H. Seitz-Moskaliuk, J. Sentkerestiová, V. Sibille, M. Slezák, M. Steidl, N. Steinbrink, M. Sturm, M. Suchopar, H. H. Telle, L. A. Thorne, T. Thümmler, N. Titov, I. Tkachev, N. Trost, K. Valerius, D. Vénos, R. Vianden, A. P. Vizcaya Hernández, N. Wandkowsky, M. Weber, C. Weinheimer, C. Weiss, S. Welte, J. Wendel, J. F. Wilkerson, J. Wolf, S. Wüstling, S. Zadoroghny
    May 3, 2018 physics.ins-det
    The KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of $0.2\,{\text{eV}/c^2}$ (90\% C.L.) by precision measurement of the shape of the tritium \textbeta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as $\textsuperscript{219}$Rn and $\textsuperscript{220}$Rn, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low- and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software Kassiopeia were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
  • Measurement of double-polarization asymmetries in the quasi-elastic $^3\vec{\mathrm{He}}(\vec{\mathrm{e}},\mathrm{e}'\mathrm{p})$ process (1804.06043)

    M. Mihovilovič, G. Jin, E. Long, Y.-W. Zhang, K. Allada, B. Anderson, J. R. M. Annand, T. Averett, W. Bertozzi, W. Boeglin, P. Bradshaw, A. Camsonne, M. Canan, G. D. Cates, C. Chen, J. P. Chen, E. Chudakov, R. De Leo, X. Deng, A. Deltuva, A. Deur, C. Dutta, L. El Fassi, D. Flay, S. Frullani, F. Garibaldi, H. Gao, S. Gilad, R. Gilman, O. Glamazdin, J. Golak, S. Golge, J. Gomez, O. Hansen, D. W. Higinbotham, T. Holmstrom, J. Huang, H. Ibrahim, C. W. de Jager, E. Jensen, X. Jiang, M. Jones, H. Kamada, H. Kang, J. Katich, H. P. Khanal, A. Kievsky, P. King, W. Korsch, J. LeRose, R. Lindgren, H.-J. Lu, W. Luo, L. E. Marcucci, P. Markowitz, M. Meziane, R. Michaels, B. Moffit, P. Monaghan, N. Muangma, S. Nanda, B. E. Norum, K. Pan, D. S. Parno, E. Piasetzky, M. Posik, V. Punjabi, A. J. R. Puckett, X. Qian, Y. Qiang, X. Qui, S. Riordan, A. Saha, P. U. Sauer, B. Sawatzky, R. Schiavilla, B. Schoenrock, M. Shabestari, A. Shahinyan, S. Širca, R. Skibiński, J. St. John, R. Subedi, V. Sulkosky, W. Tireman, W. A. Tobias, K. Topolnicki, G. M. Urciuoli, M. Viviani, D. Wang, K. Wang, Y. Wang, J. Watson, B. Wojtsekhowski, H. Witała, Z. Ye, X. Zhan, Y. Zhang, X. Zheng, B. Zhao, L. Zhu, The Jefferson Lab Hall A Collaboration
    April 17, 2018 nucl-ex
    We report on a precise measurement of double-polarization asymmetries in electron-induced breakup of $^3\mathrm{He}$ proceeding to $\mathrm{pd}$ and $\mathrm{ppn}$ final states, performed in quasi-elastic kinematics at $Q^2 = 0.25\,(\mathrm{GeV}/c)^2$ for missing momenta up to $250\,\mathrm{MeV}/c$. These observables represent highly sensitive tools to investigate the electromagnetic and spin structure of $^3\mathrm{He}$ and the relative importance of two- and three-body effects involved in the breakup reaction dynamics. The measured asymmetries cannot be satisfactorily reproduced by state-of-the-art calculations of $^3\mathrm{He}$ unless their three-body segment is adjusted, indicating that the spin-dependent part of the nuclear interaction governing the three-body breakup process is much smaller than previously thought.
  • Calibration of high voltages at the ppm level by the difference of $^{83\mathrm{m}}$Kr conversion electron lines at the KATRIN experiment (1802.05227)

    M. Arenz, W.-J. Baek, M. Beck, A. Beglarian, J. Behrens, T. Bergmann, A. Berlev, U. Besserer, K. Blaum, T. Bode, B. Bornschein, L. Bornschein, T. Brunst, N. Buzinsky, S. Chilingaryan, W. Q. Choi, M. Deffert, P. J. Doe, O. Dragoun, G. Drexlin, S. Dyba, F. Edzards, K. Eitel, E. Ellinger, R. Engel, S. Enomoto, M. Erhard, D. Eversheim, M. Fedkevych, S. Fischer, J. A. Formaggio, F. M. Fränkle, G. B. Franklin, F. Friedel, A. Fulst, W. Gil, F. Glück, A. Gonzalez Ureña, S. Grohmann, R. Grössle, R. Gumbsheimer, M. Hackenjos, V. Hannen, F. Harms, N. Haußmann, F. Heizmann, K. Helbing, W. Herz, S. Hickford, D. Hilk, D. Hillesheimer, M. A. Howe, A. Huber, A. Jansen, J. Kellerer, N. Kernert, L. Kippenbrock, M. Kleesiek, M. Klein, A. Kopmann, M. Korzeczek, A. Kovalík, B. Krasch, M. Kraus, L. Kuckert, T. Lasserre, O. Lebeda, J. Letnev, A. Lokhov, M. Machatschek, A. Marsteller, E. L. Martin, S. Mertens, S. Mirz, B. Monreal, H. Neumann, S. Niemes, A. Off, A. Osipowicz, E. Otten, D. S. Parno, A. Pollithy, A. W. P. Poon, F. Priester, P. C.-O. Ranitzsch, O. Rest, R. G. H. Robertson, C. Rodenbeck, M. Röllig, C. Röttele, M. Ryšavý, R. Sack, A. Saenz, L. Schimpf, K. Schlösser, M. Schlösser, K. Schönung, M. Schrank, H. Seitz-Moskaliuk, J. Sentkerestiová, V. Sibille, M. Slezák, M. Steidl, N. Steinbrink, M. Sturm, M. Suchopar, M. Suesser, H. H. Telle, L. A. Thorne, T. Thümmler, N. Titov, I. Tkachev, N. Trost, K. Valerius, D. Vénos, R. Vianden, A. P. Vizcaya Hernández, M. Weber, C. Weinheimer, C. Weiss, S. Welte, J. Wendel, J. F. Wilkerson, J. Wolf, S. Wüstling, S. Zadoroghny
    Feb. 14, 2018 physics.ins-det
    The neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at -18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two $^{83\mathrm{m}}$Kr conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor $M=1972.449(10)$ of the high-voltage divider K35 is in agreement with the last PTB calibration four years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
  • First transmission of electrons and ions through the KATRIN beamline (1802.04167)

    M. Arenz, W.-J. Baek, M. Beck, A. Beglarian, J. Behrens, T. Bergmann, A. Berlev, U. Besserer, K. Blaum, T. Bode, B. Bornschein, L. Bornschein, T. Brunst, N. Buzinsky, S. Chilingaryan, W. Q. Choi, M. Deffert, P. J. Doe, O. Dragoun, G. Drexlin, S. Dyba, F. Edzards, K. Eitel, E. Ellinger, R. Engel, S. Enomoto, M. Erhard, D. Eversheim, M. Fedkevych, S. Fischer, J. A. Formaggio, F. M. Fränkle, G. B. Franklin, F. Friedel, A. Fulst, W. Gil, F. Glück, A. Gonzalez Ureña, S. Grohmann, R. Grössle, R. Gumbsheimer, M. Hackenjos, V. Hannen, F. Harms, N. Haußmann, F. Heizmann, K. Helbing, W. Herz, S. Hickford, D. Hilk, D. Hillesheimer, M. A. Howe, A. Huber, A. Jansen, J. Kellerer, N. Kernert, L. Kippenbrock, M. Kleesiek, M. Klein, A. Kopmann, M. Korzeczek, A. Kovalík, B. Krasch, M. Kraus, L. Kuckert, T. Lasserre, O. Lebeda, J. Letnev, A. Lokhov, M. Machatschek, A. Marsteller, E. L. Martin, S. Mertens, S. Mirz, B. Monreal, U. Naumann, H. Neumann, S. Niemes, A. Off, H.-W. Ortjohann, A. Osipowicz, E. Otten, D. S. Parno, A. Pollithy, A. W. P. Poon, F. Priester, P. C.-O. Ranitzsch, O. Rest, R. G. H. Robertson, C. Rodenbeck, M. Röllig, C. Röttele, M. Ryšavý, R. Sack, A. Saenz, L. Schimpf, K. Schlösser, M. Schlösser, K. Schönung, M. Schrank, H. Seitz-Moskaliuk, J. Sentkerestiová, V. Sibille, M. Slezák, M. Steidl, N. Steinbrink, M. Sturm, M. Suchopar, M. Suesser, H. H. Telle, L. A. Thorne, T. Thümmler, N. Titov, I. Tkachev, N. Trost, K. Valerius, D. Vénos, R. Vianden, A. P. Vizcaya Hernández, M. Weber, C. Weinheimer, C. Weiss, S. Welte, J. Wendel, J. F. Wilkerson, J. Wolf, S. Wüstling, S. Zadoroghny
    Feb. 12, 2018 nucl-ex, physics.ins-det
    The Karlsruhe Tritium Neutrino (KATRIN) experiment is a large-scale effort to probe the absolute neutrino mass scale with a sensitivity of 0.2 eV (90% confidence level), via a precise measurement of the endpoint spectrum of tritium beta decay. This work documents several KATRIN commissioning milestones: the complete assembly of the experimental beamline, the successful transmission of electrons from three sources through the beamline to the primary detector, and tests of ion transport and retention. In the First Light commissioning campaign of Autumn 2016, photoelectrons were generated at the rear wall and ions were created by a dedicated ion source attached to the rear section; in July 2017, gaseous Kr-83m was injected into the KATRIN source section, and a condensed Kr-83m source was deployed in the transport section. In this paper we describe the technical details of the apparatus and the configuration for each measurement, and give first results on source and system performance. We have successfully achieved transmission from all four sources, established system stability, and characterized many aspects of the apparatus.
  • Measurements of $d_{2}^{n}$ and $A_{1}^{n}$: Probing the neutron spin structure (1603.03612)

    D. Flay, M. Posik, D. S. Parno, K. Allada, W. Armstrong, T. Averett, F. Benmokhtar, W. Bertozzi, A. Camsonne, M. Canan, G. D. Cates, C. Chen, J.-P. Chen, S. Choi, E. Chudakov, F. Cusanno, M. M. Dalton, W. Deconinck, C. W. de Jager, X. Deng, A. Deur, C. Dutta, L. El Fassi, G. B. Franklin, M. Friend, H. Gao, F. Garibaldi, S. Gilad, R. Gilman, O. Glamazdin, S. Golge, J. Gomez, L. Guo, O. Hansen, D. W. Higinbotham, T. Holmstrom, J. Huang, C. Hyde, H. F. Ibrahim, X. Jiang, G. Jin, J. Katich, A. Kelleher, A. Kolarkar, W. Korsch, G. Kumbartzki, J. J. LeRose, R. Lindgren, N. Liyanage, E. Long, A. Lukhanin, V. Mamyan, D. McNulty, Z.-E. Meziani, R. Michaels, M. Mihovilovič, B. Moffit, N. Muangma, S. Nanda, A. Narayan, V. Nelyubin, B. Norum, Y. Oh, J. C. Peng, X. Qian, Y. Qiang, A. Rakhman, S. Riordan, A. Saha, B. Sawatzky, M. H. Shabestari, A. Shahinyan, S. Širca, P. Solvignon, R. Subedi, V. Sulkosky, A. Tobias, W. Troth, D. Wang, Y. Wang, B. Wojtsekhowski, X. Yan, H. Yao, Y. Ye, Z. Ye, L. Yuan, X. Zhan, Y. Zhang, Y.-W. Zhang, B. Zhao, X. Zheng
    June 28, 2016 nucl-ex, nucl-th
    ... ... ... ... ... ...
    We report on the results of the E06-014 experiment performed at Jefferson Lab in Hall A, where a precision measurement of the twist-3 matrix element $d_2$ of the neutron ($d_{2}^{n}$) was conducted. This quantity represents the average color Lorentz force a struck quark experiences in a deep inelastic electron scattering event off a neutron due to its interaction with the hadronizing remnants. This color force was determined from a linear combination of the third moments of the spin structure functions $g_1$ and $g_2$ on $^{3}$He after nuclear corrections had been applied to these moments. The kinematics included two average $Q^{2}$ bins of $3.2$ GeV$^{2}$ and $4.3$ GeV$^{2}$, and Bjorken-$x$ $0.25 \leq x \leq 0.90$ covering the DIS and resonance regions. We found $d_2^n$ to be small and negative for $<Q^{2}> = 3.2$ GeV$^{2}$, and smaller for $<Q^{2}> = 4.3$ GeV$^{2}$, consistent with a lattice QCD calculation. The twist-4 matrix element $f_{2}^{n}$ was extracted by combining our $d_{2}^{n}$ with the world data on $\Gamma_{1}^{n} = \int_{0}^{1} g_{1}^{n} dx$. We found $f_{2}^{n}$ to be roughly an order of magnitude larger than $d_{2}^{n}$. Utilizing the extracted $d_{2}^{n}$ and $f_{2}^{n}$ data, we separated the color force into its electric and magnetic components, $F_{E}^{y,n}$ and $F_{B}^{y,n}$, and found them to be equal and opposite in magnitude, in agreement with instanton model predictions but not with those from QCD sum rules. Additionally, we have extracted the neutron virtual photon-nucleon asymmetry $A_{1}^{n}$, the structure function ratio $g_{1}^{n}/F_{1}^{n}$, and the quark ratios $(\Delta u + \Delta \bar{u})/(u + \bar{u})$ and $(\Delta d + \Delta \bar{d})/(d + \bar{d})$. These results were found to be consistent with DIS world data and with the prediction of the constituent quark model but at odds with those of perturbative QCD at large $x$.
  • Focal-plane detector system for the KATRIN experiment (1404.2925)

    J. F. Amsbaugh, J. Barrett, A. Beglarian, T. Bergmann, H. Bichsel, L. I. Bodine, J. Bonn, N. M. Boyd, T. H. Burritt, Z. Chaoui, S. Chilingaryan, T. J. Corona, P. J. Doe, J. A. Dunmore, S. Enomoto, J. Fischer, J. A. Formaggio, F. M. Fränkle, D. Furse, H. Gemmeke, F. Glück, F. Harms, G. C. Harper, J. Hartmann, M. A. Howe, A. Kaboth, J. Kelsey, M. Knauer, A. Kopmann, M. L. Leber, E. L. Martin, K. J. Middleman, A. W. Myers, N. S. Oblath, D. S. Parno, D. A. Peterson, L. Petzold, D. G. Phillips II, P. Renschler, R. G. H. Robertson, J. Schwarz, M. Steidl, D. Tcherniakhovski, T. Thümmler, T. D. Van Wechel, B. A. VanDevender, S. Vöcking, B. L. Wall, K. L. Wierman, J. F. Wilkerson, S. Wüstling
    Jan. 28, 2015 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
  • Precision Measurements of $A_1^n$ in the Deep Inelastic Regime (1406.1207)

    D. S. Parno, D. Flay, M. Posik, K. Allada, W. Armstrong, T. Averett, F. Benmokhtar, W. Bertozzi, A. Camsonne, M. Canan, G. D. Cates, C. Chen, J.-P. Chen, S. Choi, E. Chudakov, F. Cusanno, M. M. Dalton, W. Deconinck, C. W. de Jager, X. Deng, A. Deur, C. Dutta, L. El Fassi, G. B. Franklin, M. Friend, H. Gao, F. Garibaldi, S. Gilad, R. Gilman, O. Glamazdin, S. Golge, J. Gomez, L. Guo, O. Hansen, D. W. Higinbotham, T. Holmstrom, J. Huang, C. Hyde, H. F. Ibrahim, X. Jiang, G. Jin, J. Katich, A. Kelleher, A. Kolarkar, W. Korsch, G. Kumbartzki, J. J. LeRose, R. Lindgren, N. Liyanage, E. Long, A. Lukhanin, V. Mamyan, D. McNulty, Z.-E. Meziani, R. Michaels, M. Mihovilovič, B. Moffit, N. Muangma, S. Nanda, A. Narayan, V. Nelyubin, B. Norum, Nuruzzaman, Y. Oh, J. C. Peng, X. Qian, Y. Qiang, A. Rakhman, S. Riordan, A. Saha, B. Sawatzky, M. H. Shabestari, A. Shahinyan, S. Širca, P. Solvignon, R. Subedi, V. Sulkosky, W. A. Tobias, W. Troth, D. Wang, Y. Wang, B. Wojtsekhowski, X. Yan, H. Yao, Y. Ye, Z. Ye, L. Yuan, X. Zhan, Y. Zhang, Y.-W. Zhang, B. Zhao, X. Zheng (The Jefferson Lab Hall A Collaboration)
    Aug. 1, 2019 nucl-ex
    ... ... ... ... ... ...
    We have performed precision measurements of the double-spin virtual-photon asymmetry $A_1$ on the neutron in the deep inelastic scattering regime, using an open-geometry, large-acceptance spectrometer. Our data cover a wide kinematic range $0.277 \leq x \leq 0.548$ at an average $Q^2$ value of 3.078~(GeV/c)$^2$, doubling the available high-precision neutron data in this $x$ range. We have combined our results with world data on proton targets to extract the ratio of polarized-to-unpolarized parton distribution functions for up quarks and for down quarks in the same kinematic range. Our data are consistent with a previous observation of an $A_1^n$ zero crossing near $x=0.5$. We find no evidence of a transition to a positive slope in $(\Delta d + \Delta \bar{d})/(d + \bar{d})$ up to $x=0.548$.
  • A Precision Measurement of the Neutron Twist-3 Matrix Element $d_2^n$: Probing Color Forces (1404.4003)

    M. Posik, D. Flay, D. S. Parno, K. Allada, W. Armstrong, T. Averett, F. Benmokhtar, W. Bertozzi, A. Camsonne, M. Canan, G.D. Cates, C. Chen, J.-P. Chen, S. Choi, E. Chudakov, F. Cusanno, M. M. Dalton, W. Deconinck, C. W. de Jager, X. Deng, A. Deur, C. Dutta, L. El Fassi, G. B. Franklin, M. Friend, H. Gao, F. Garibaldi, S. Gilad, R. Gilman, O. Glamazdin, S. Golge, J. Gomez, L. Guo, O. Hansen, D. W. Higinbotham, T. Holmstrom, J. Huang, C. Hyde, H. F. Ibrahim, X. Jiang, G. Jin, J. Katich, A. Kelleher, A. Kolarkar, W. Korsch, G. Kumbartzki, J.J. LeRose, R. Lindgren, N. Liyanage, E. Long, A. Lukhanin, V. Mamyan, D. McNulty, Z.-E. Meziani, R. Michaels, M. Mihovilovič, B. Moffit, N. Muangma, S. Nanda, A. Narayan, V. Nelyubin, B. Norum, Nuruzzaman, Y. Oh, J. C. Peng, X. Qian, Y. Qiang, A. Rakhman, S. Riordan, A. Saha, B. Sawatzky, M. H. Shabestari, A. Shahinyan, S. Širca, P. Solvignon, R. Subedi, V. Sulkosky, W. A. Tobias, W. Troth, D. Wang, Y. Wang, B. Wojtsekhowski, X. Yan, H. Yao, Y. Ye, Z. Ye, L. Yuan, X. Zhan, Y. Zhang, Y.-W. Zhang, B. Zhao, X. Zheng,
    July 3, 2014 nucl-ex
    ... ... ... ... ... ...
    Double-spin asymmetries and absolute cross sections were measured at large Bjorken $x$ (0.25 $ \le x \le $ 0.90), in both the deep-inelastic and resonance regions, by scattering longitudinally polarized electrons at beam energies of 4.7 and 5.9 GeV from a transversely and longitudinally polarized $^3$He target. In this dedicated experiment, the spin structure function $g_2$ on $^3$He was determined with precision at large $x$, and the neutron twist-three matrix element $d_2^n$ was measured at $\left< Q^2\right>$ of 3.21 and 4.32 GeV$^2$/$c^2$, with an absolute precision of about $10^{-5}$. Our results are found to be in agreement with lattice QCD calculations and resolve the disagreement found with previous data at $\left< Q^2\right> =$ 5 GeV$^2$/$c^2$. Combining $d_2^n$ and a newly extracted twist-four matrix element, $f_2^n$, the average neutron color electric and magnetic forces were extracted and found to be of opposite sign and about 30 MeV/fm in magnitude.
  • Dead layer on silicon p-i-n diode charged-particle detectors (1310.1178)

    B. L. Wall, J. F. Amsbaugh, A. Beglarian, T. Bergmann, H. C. Bichsel, L. I. Bodine, N. M. Boyd, T. H. Burritt, Z. Chaoui, T. J. Corona, P. J. Doe, S. Enomoto, F. Harms, G. C. Harper, M. A. Howe, E. L. Martin, D. S. Parno, D. A. Peterson, L. Petzold, P. Renschler, R. G. H. Robertson, J. Schwarz, M. Steidl, T. D. Van Wechel, B. A. VanDevender, S. Wüstling, K. J. Wierman, , J. F. Wilkerson
    Oct. 7, 2013 hep-ex, nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by diffusion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.
  • Comparison of Modeled and Measured Performance of a GSO Crystal as Gamma Detector (1211.3710)

    D. S. Parno, M. Friend, V. Mamyan, F. Benmokhtar, A. Camsonne, G. B. Franklin, K. Paschke, B. Quinn
    May 24, 2013 physics.ins-det
    ... ... ... ... ... ...
    We have modeled, tested, and installed a large, cerium-activated Gd2SiO5 crystal scintillator for use as a detector of gamma rays. We present the measured detector response to two types of incident photons: nearly monochromatic photons up to 40 MeV, and photons from a continuous Compton backscattering spectrum up to 200 MeV. Our GEANT4 simulations, developed to determine the analyzing power of the Compton polarimeter in Hall A of Jefferson Lab, reproduce the measured spectra well.