-
Key performance characteristics are demonstrated for the microwave SQUID
multiplexer ($\mu$MUX) coupled to transition edge sensor (TES) bolometers that
have been optimized for cosmic microwave background (CMB) observations. In a
64-channel demonstration, we show that the $\mu$MUX produces a white, input
referred current noise level of 29~pA$/\sqrt{\mathrm{Hz}}$ at -77~dB microwave
probe tone power, which is well below expected fundamental detector and photon
noise sources for a ground-based CMB-optimized bolometer. Operated with
negligible photon loading, we measure 98~pA$/\sqrt{\mathrm{Hz}}$ in the
TES-coupled channels biased at 65% of the sensor normal resistance. This noise
level is consistent with that predicted from bolometer thermal fluctuation
(i.e., phonon) noise. Furthermore, the power spectral density exhibits a white
spectrum at low frequencies ($\sim$~100~mHz), which enables CMB mapping on
large angular scales that constrain the physics of inflation. Additionally, we
report cross-talk measurements that indicate a level below 0.3%, which is less
than the level of cross-talk from multiplexed readout systems in deployed CMB
imagers. These measurements demonstrate the $\mu$MUX as a viable readout
technique for future CMB imaging instruments.
-
We introduce a new technique for determining x-ray fluorescence line energies
and widths, and we present measurements made with this technique of 22 x-ray L
lines from lanthanide-series elements. The technique uses arrays of
transition-edge sensors, microcalorimeters with high energy-resolving power
that simultaneously observe both calibrated x-ray standards and the x-ray
emission lines under study. The uncertainty in absolute line energies is
generally less than 0.4 eV in the energy range of 4.5 keV to 7.5 keV. Of the
seventeen line energies of neodymium, samarium, and holmium, thirteen are found
to be consistent with the available x-ray reference data measured after 1990;
only two of the four lines for which reference data predate 1980, however, are
consistent with our results. Five lines of terbium are measured with
uncertainties that improve on those of existing data by factors of two or more.
These results eliminate a significant discrepancy between measured and
calculated x-ray line energies for the terbium Ll line (5.551 keV). The line
widths are also measured, with uncertainties of 0.6 eV or less on the
full-width at half-maximum in most cases. These measurements were made with an
array of approximately one hundred superconducting x- ray microcalorimeters,
each sensitive to an energy band from 1 keV to 8 keV. No energy-dispersive
spectrometer has previously been used for absolute-energy estimation at this
level of accuracy. Future spectrometers, with superior linearity and energy
resolution, will allow us to improve on these results and expand the
measurements to more elements and a wider range of line energies.
-
In recent years, the progress on low temperature detector technologies has
allowed design of large scale experiments aiming at pushing down the
sensitivity on the neutrino mass below 1\,eV. Even with outstanding
performances in both energy ($\sim$eV on keV) and time resolution ($\sim
1\,\mu$s) on the single channel, a large number of detectors working in
parallel is required to reach a sub-eV sensitivity. HOLMES is a new experiment
to directly measure the neutrino mass with a sensitivity as low as 2\,eV.
HOLMES will perform a calorimetric measurement of the energy released in the
electron capture (EC) decay of 163Ho. In its final configuration, HOLMES will
deploy 1000 detectors of low temperature microcalorimeters with implanted 163Ho
nuclei. The baseline sensors for HOLMES are Mo/Cu TESs (Transition Edge
Sensors) on SiN\textsubscript{x} membrane with gold absorbers. The readout is
based on the use of rf-SQUIDs as input devices with flux ramp modulation for
linearization purposes; the rf-SQUID is then coupled to a superconducting
lambda/4-wave resonator in the GHz range, and the modulated signal is finally
read out using the homodyne technique. The TES detectors have been designed
with the aim of achieving an energy resolution of a few eV at the spectrum
endpoint and a time resolution of a few micro-seconds, in order to minimize
pile-up artifacts.
-
A performance evaluation of superconducting transition-edge sensors (TESs) in
the environment of a pion beam line at a particle accelerator is presented.
Averaged across the 209 functioning sensors in the array, the achieved energy
resolution is 5.2 eV FWHM at Co $K_{\alpha}$ (6.9 keV) when the pion beam is
off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of
$\pm$0.04 eV is demonstrated for Fe $K_{\alpha}$ (6.4 keV) with in-situ energy
calibration obtained from other nearby known x-ray lines. To achieve this small
uncertainty, it is essential to consider the non-Gaussian energy response of
the TESs and thermal cross-talk pile-up effects due to charged-particle hits in
the silicon substrate of the TES array.
-
We introduce a filter-construction method for pulse processing that differs
in two respects from that in standard optimal filtering, in which the average
pulse shape and noise-power spectral density are combined to create a
convolution filter for estimating pulse heights. First, the proposed filters
are computed in the time domain, to avoid periodicity artifacts of the discrete
Fourier transform, and second, orthogonality constraints are imposed on the
filters, to reduce the filtering procedure's sensitivity to unknown baseline
height and pulse tails. We analyze the proposed filters, predicting energy
resolution under several scenarios, and apply the filters to high-rate pulse
data from gamma-rays measured by a transition-edge-sensor microcalorimeter.