Using an offline cross-correlation technique, we have analyzed the noise
behavior of a new type of optical frequency comb (OFC), which is carrier
envelope offset (CEO) free by configuration, due to difference frequency
generation. In order to evaluate the instrument's ultimate noise floor, the
phase and amplitude noise of a stabilized OFC are measured simultaneously using
two analog-to-digital converters. Carrier recovery and phase detection are done
by post-processing, eliminating the need for external phase-locked loops and
complex calibration techniques. In order to adapt the measurement noise floor
and the number of averages used in cross correlation, an adaptive frequency
resolution for noise measurement is applied. Phase noise results are in
excellent agreement with measurements of the fluctuations of the repetition
frequency of the OFC obtained from optical signal.
-
PFS (Prime Focus Spectrograph), a next generation facility instrument on the
8.2-meter Subaru Telescope, is a very wide-field, massively multiplexed,
optical and near-infrared spectrograph. Exploiting the Subaru prime focus, 2394
reconfigurable fibers will be distributed over the 1.3 deg field of view. The
spectrograph has been designed with 3 arms of blue, red, and near-infrared
cameras to simultaneously observe spectra from 380nm to 1260nm in one exposure
at a resolution of ~1.6-2.7A. An international collaboration is developing this
instrument under the initiative of Kavli IPMU. The project is now going into
the construction phase aiming at undertaking system integration in 2017-2018
and subsequently carrying out engineering operations in 2018-2019. This article
gives an overview of the instrument, current project status and future paths
forward.
-
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multifiber
spectrograph with 2394 science fibers distributed across a 1.3-deg diameter
field of view at the Subaru 8.2-m telescope. The wide wavelength coverage from
0.38 {\mu}m to 1.26 {\mu}m, with a resolving power of 3000, simultaneously
strengthens its ability to target three main survey programs: cosmology,
galactic archaeology and galaxy/AGN evolution. A medium resolution mode with a
resolving power of 5000 for 0.71 {\mu}m to 0.89 {\mu}m will also be available
by simply exchanging dispersers. We highlight some of the technological aspects
of the design. To transform the telescope focal ratio, a broad-band coated
microlens is glued to each fiber tip. A higher transmission fiber is selected
for the longest part of the cable system, optimizing overall throughput; a
fiber with low focal ratio degradation is selected for the fiber-positioner and
fiber-slit components, minimizing the effects of fiber movements and fiber
bending. Fiber positioning will be performed by a positioner consisting of two
stages of piezo-electric rotary motors. The positions of these motors are
measured by taking an image of artificially back-illuminated fibers with the
metrology camera located in the Cassegrain container; the fibers are placed in
the proper location by iteratively measuring and then adjusting the positions
of the motors. Target light reaches one of the four identical fast-Schmidt
spectrograph modules, each with three arms. The PFS project has passed several
project-wide design reviews and is now in the construction phase.
-
The Prime Focus Spectrograph (PFS) is an optical/near-infrared multi-fiber
spectrograph with 2394 science fibers, which are distributed in 1.3 degree
diameter field of view at Subaru 8.2-meter telescope. The simultaneous wide
wavelength coverage from 0.38 um to 1.26 um, with the resolving power of 3000,
strengthens its ability to target three main survey programs: cosmology,
Galactic archaeology, and galaxy/AGN evolution. A medium resolution mode with
resolving power of 5000 for 0.71 um to 0.89 um also will be available by simply
exchanging dispersers. PFS takes the role for the spectroscopic part of the
Subaru Measurement of Images and Redshifts project, while Hyper Suprime-Cam
works on the imaging part. To transform the telescope plus WFC focal ratio, a
3-mm thick broad-band coated glass-molded microlens is glued to each fiber tip.
A higher transmission fiber is selected for the longest part of cable system,
while one with a better FRD performance is selected for the fiber-positioner
and fiber-slit components, given the more frequent fiber movements and tightly
curved structure. Each Fiber positioner consists of two stages of
piezo-electric rotary motors. Its engineering model has been produced and
tested. Fiber positioning will be performed iteratively by taking an image of
artificially back-illuminated fibers with the Metrology camera located in the
Cassegrain container. The camera is carefully designed so that fiber position
measurements are unaffected by small amounts of high special-frequency
inaccuracies in WFC lens surface shapes. Target light carried through the fiber
system reaches one of four identical fast-Schmidt spectrograph modules, each
with three arms. Prototype VPH gratings have been optically tested. CCD
production is complete, with standard fully-depleted CCDs for red arms and
more-challenging thinner fully-depleted CCDs with blue-optimized coating for
blue arms.