The prospect of pileup induced backgrounds at the High Luminosity LHC
(HL-LHC) has stimulated intense interest in developing technologies for charged
particle detection with accurate timing at high rates. The required accuracy
follows directly from the nominal interaction distribution within a bunch
crossing ($\sigma_z\sim5$ cm, $\sigma_t\sim170$ ps). A time resolution of the
order of 20-30 ps would lead to significant reduction of these backgrounds.
With this goal, we present a new detection concept called PICOSEC, which is
based on a "two-stage" Micromegas detector coupled to a Cherenkov radiator and
equipped with a photocathode. First results obtained with this new detector
yield a time resolution of 24 ps for 150 GeV muons, and 76 ps for single
photoelectrons.
-
The TOTEM collaboration has measured the proton-proton total cross section at
$\sqrt{s}=13$ TeV with a luminosity-independent method. Using dedicated
$\beta^{*}=90$ m beam optics, the Roman Pots were inserted very close to the
beam. The inelastic scattering rate has been measured by the T1 and T2
telescopes during the same LHC fill. After applying the optical theorem the
total proton-proton cross section is $\sigma_{\rm tot}=(110.6 \pm 3.4$) mb,
well in agreement with the extrapolation from lower energies. This method also
allows one to derive the luminosity-independent elastic and inelastic cross
sections: $\sigma_{\rm el} = (31.0 \pm 1.7)$ mb and $\sigma_{\rm inel} = (79.5
\pm 1.8)$ mb.
-
This paper describes the design and the performance of the timing detector
developed by the TOTEM Collaboration for the Roman Pots (RPs) to measure the
Time-Of-Flight (TOF) of the protons produced in central diffractive
interactions at the LHC. The measurement of the TOF of the protons allows the
determination of the longitudinal position of the proton interaction vertex and
its association with one of the vertices reconstructed by the CMS detectors.
The TOF detector is based on single crystal Chemical Vapor Deposition (scCVD)
diamond plates and is designed to measure the protons TOF with about 50 ps time
precision. This upgrade to the TOTEM apparatus will be used in the LHC run 2
and will tag the central diffractive events up to an interaction pileup of
about 1. A dedicated fast and low noise electronics for the signal
amplification has been developed. The digitization of the diamond signal is
performed by sampling the waveform. After introducing the physics studies that
will most profit from the addition of these new detectors, we discuss in detail
the optimization and the performance of the first TOF detector installed in the
LHC in November 2015.
-
The TOTEM experiment at the CERN LHC has measured elastic proton-proton
scattering at the centre-of-mass energy $\sqrt{s}$ = 8 TeV and four-momentum
transfers squared, |t|, from 6 x $10^{-4}$ GeV$^2$ to 0.2 GeV$^2$. Near the
lower end of the |t|-interval the differential cross-section is sensitive to
the interference between the hadronic and the electromagnetic scattering
amplitudes. This article presents the elastic cross-section measurement and the
constraints it imposes on the functional forms of the modulus and phase of the
hadronic elastic amplitude. The data exclude the traditional Simplified West
and Yennie interference formula that requires a constant phase and a purely
exponential modulus of the hadronic amplitude. For parametrisations of the
hadronic modulus with second- or third-order polynomials in the exponent, the
data are compatible with hadronic phase functions giving either central or
peripheral behaviour in the impact parameter picture of elastic scattering. In
both cases, the $\rho$-parameter is found to be 0.12 $\pm$ 0.03. The results
for the total hadronic cross-section are $\sigma_{tot}$ = (102.9 $\pm$ 2.3) mb
and (103.0 $\pm$ 2.3) mb for central and peripheral phase formulations,
respectively. Both are consistent with previous TOTEM measurements.
-
In-beam evaluation of a fully-equipped medium-size 30$\times$30 cm$^2$
Resistive Plate WELL (RPWELL) detector is presented. It consists here of a
single element gas-avalanche multiplier with Semitron ESD225 resistive plate, 1
cm$^2$ readout pads and APV25/SRS electronics. Similarly to previous results
with small detector prototypes, stable operation at high detection efficiency
(>98%) and low average pad multiplicity (~1.2) were recorded with 150 GeV muon
and high-rate pion beams, in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and Ar/(7%CO$_2$).
This is an important step towards the realization of robust detectors suitable
for applications requiring large-area coverage; among them Digital Hadron
Calorimetry.
-
A thin single-element THGEM-based, Resistive-Plate WELL (RPWELL) detector was
operated with 150 GeV/c muon and pion beams in Ne/(5%CH$_4$), Ar/(5%CH$_4$) and
Ar/(7%CO$_2$); signals were recorded with 1 cm$^2$ square pads and SRS/APV25
electronics. Detection efficiency values greater than 98% were reached in all
the gas mixtures, at average pad multiplicity of 1.2. The use of the
10$^9${\Omega}cm resistive plate resulted in a completely discharge-free
operation also in intense pion beams. The efficiency remained essentially
constant at 98-99% up to fluxes of $\sim$10$^4$Hz/cm$^2$, dropping by a few %
when approaching 10$^5$ Hz/cm$^2$. These results pave the way towards
cost-effective, robust, efficient, large-scale detectors for a variety of
applications in future particle, astro-particle and applied fields. A potential
target application is digital hadron calorimetry.
-
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been
utilised to assess and monitor the flatness of Gaseous Electron Multipliers
(GEM) foils. The setup layout and preliminary results are presented.
-
We present a novel application of Fiber Bragg Grating (FBG) sensors in the
construction and characterisation of Micro Pattern Gaseous Detector (MPGD),
with particular attention to the realisation of the largest triple (Gas
electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the
CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of
about 0.5 m2 active area each, employing three GEM foils per chamber, to be
installed in the forward region of the CMS endcap during the long shutdown of
LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM
foils that are mechanically stretched in order to secure their flatness and the
consequent uniform performance of the GE1/1 chamber across its whole active
surface. So far FBGs have been used in high energy physics mainly as high
precision positioning and re-positioning sensors and as low cost, easy to
mount, low space consuming temperature sensors. FBGs are also commonly used for
very precise strain measurements in material studies. In this work we present a
novel use of FBGs as flatness and mechanical tensioning sensors applied to the
wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used
to determine the optimal mechanical tension applied and to characterise the
mechanical tension that should be applied to the foils. We discuss the results
of the test done on a full-sized GE1/1 final prototype, the studies done to
fully characterise the GEM material, how this information was used to define a
standard assembly procedure and possible future developments.
-
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice
with remarkable mechanical and electrical properties. Regarded as the thinnest
and narrowest conductive mesh, it has drastically different transmission
behaviours when bombarded with electrons and ions in vacuum. This property, if
confirmed in gas, may be a definitive solution for the ion back-flow problem in
gaseous detectors. In order to ascertain this aspect, graphene layers of
dimensions of about 2x2cm$^2$, grown on a copper substrate, are transferred
onto a flat metal surface with holes, so that the graphene layer is freely
suspended. The graphene and the support are installed into a gaseous detector
equipped with a triple Gaseous Electron Multiplier (GEM), and the transparency
properties to electrons and ions are studied in gas as a function of the
electric fields. The techniques to produce the graphene samples are described,
and we report on preliminary tests of graphene-coated GEMs.
-
A comprehensive study, supported by systematic measurements and numerical
computations, of the intrinsic limits of multi-GEM detectors when exposed to
very high particle fluxes or operated at very large gains is presented. The
observed variations of the gain, of the ion back-flow, and of the pulse height
spectra are explained in terms of the effects of the spatial distribution of
positive ions and their movement throughout the amplification structure. The
intrinsic dynamic character of the processes involved imposes the use of a
non-standard simulation tool for the interpretation of the measurements.
Computations done with a Finite Element Analysis software reproduce the
observed behaviour of the detector. The impact of this detailed description of
the detector in extreme conditions is multiple: it clarifies some detector
behaviours already observed, it helps in defining intrinsic limits of the GEM
technology, and it suggests ways to extend them.
-
The TOTEM experiment has made a precise measurement of the elastic
proton-proton differential cross-section at the centre-of-mass energy sqrt(s) =
8 TeV based on a high-statistics data sample obtained with the beta* = 90
optics. Both the statistical and systematic uncertainties remain below 1%,
except for the t-independent contribution from the overall normalisation. This
unprecedented precision allows to exclude a purely exponential differential
cross-section in the range of four-momentum transfer squared 0.027 < |t| < 0.2
GeV^2 with a significance greater than 7 sigma. Two extended parametrisations,
with quadratic and cubic polynomials in the exponent, are shown to be well
compatible with the data. Using them for the differential cross-section
extrapolation to t = 0, and further applying the optical theorem, yields total
cross-section estimates of (101.5 +- 2.1) mb and (101.9 +- 2.1) mb,
respectively, in agreement with previous TOTEM measurements.
-
Graphene is a single layer of carbon atoms arranged in a honeycomb lattice
with remarkable mechanical, electrical and optical properties. For the first
time graphene layers suspended on copper meshes were installed into a gas
detector equipped with a gaseous electron multiplier. Measurements of low
energy electron and ion transfer through graphene were conducted. In this paper
we describe the sample preparation for suspended graphene layers, the testing
procedures and we discuss the preliminary results followed by a prospect of
further applications.
-
Gas Electron Multiplier (GEM) technology is being considered for the forward
muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first
implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid <
2.2$ region of the muon endcap mainly to control muon level-1 trigger rates
after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by
3,072 radial strips with 455 $\mu$rad pitch arranged in eight $\eta$-sectors.
We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and
tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and
the RD51 scalable readout system. Four small GEM detectors with 2-D readout and
an average measured azimuthal resolution of 36 $\mu$rad provided precise
reference tracks. Construction of this largest GEM detector built to-date is
described. Strip cluster parameters, detection efficiency, and spatial
resolution are studied with position and high voltage scans. The plateau
detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is
found to be [123.5 $\pm$ 1.6 (stat)] $\mu$rad when operating in the center of
the efficiency plateau and using full pulse height information. The resolution
can be slightly improved by $\sim$ 10 $\mu$rad when correcting for the bias due
to discrete readout strips. The CMS upgrade design calls for readout
electronics with binary hit output. When strip clusters are formed
correspondingly without charge-weighting and with fixed hit thresholds, a
position resolution of [136.8 $\pm$ 2.5 stat] $\mu$rad is measured, consistent
with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $\mu$rad. Other
$\eta$-sectors of the detector show similar response and performance.
-
The pseudorapidity density of charged particles dN(ch)/deta is measured by
the TOTEM experiment in pp collisions at sqrt(s) = 8 TeV within the range 3.9 <
eta < 4.7 and -6.95 < eta < -6.9. Data were collected in a low intensity LHC
run with collisions occurring at a distance of 11.25 m from the nominal
interaction point. The data sample is expected to include 96-97\% of the
inelastic proton-proton interactions. The measurement reported here considers
charged particles with p_T > 0 MeV/c, produced in inelastic interactions with
at least one charged particle in -7 < eta < -6 or 3.7 < eta <4.8 . The
dN(ch)/deta has been found to decrease with |eta|, from 5.11 +- 0.73 at eta =
3.95 to 1.81 +- 0.56 at eta= - 6.925. Several MC generators are compared to the
data and are found to be within the systematic uncertainty of the measurement.
-
Precise knowledge of the beam optics at the LHC is crucial to fulfil the
physics goals of the TOTEM experiment, where the kinematics of the scattered
protons is reconstructed with the near-beam telescopes -- so-called Roman Pots
(RP). Before being detected, the protons' trajectories are influenced by the
magnetic fields of the accelerator lattice. Thus precise understanding of the
proton transport is of key importance for the experiment. A novel method of
optics evaluation is proposed which exploits kinematical distributions of
elastically scattered protons observed in the RPs. Theoretical predictions, as
well as Monte Carlo studies, show that the residual uncertainty of this optics
estimation method is smaller than 0.25 percent.
-
The TOTEM Experiment is designed to measure the total proton-proton
cross-section with the luminosity-independent method and to study elastic and
diffractive pp scattering at the LHC. To achieve optimum forward coverage for
charged particles emitted by the pp collisions in the interaction point IP5,
two tracking telescopes, T1 and T2, are installed on each side of the IP in the
pseudorapidity region 3.1 < = |eta | < = 6.5, and special movable beam-pipe
insertions - called Roman Pots (RP) - are placed at distances of +- 147 m and
+- 220 m from IP5. This article describes in detail the working of the TOTEM
detector to produce physics results in the first three years of operation and
data taking at the LHC.
-
The first double diffractive cross-section measurement in the very forward
region has been carried out by the TOTEM experiment at the LHC with
center-of-mass energy of sqrt(s)=7 TeV. By utilizing the very forward TOTEM
tracking detectors T1 and T2, which extend up to |eta|=6.5, a clean sample of
double diffractive pp events was extracted. From these events, we measured the
cross-section sigma_DD =(116 +- 25) mub for events where both diffractive
systems have 4.7 <|eta|_min < 6.5 .
-
Beam studies of thin single- and double-stage THGEM-based detectors are
presented. Several 10 x 10 cm^2 configurations with a total thickness of 5-6 mm
(excluding readout electronics), with 1 x 1 cm^2 pads inductively coupled
through a resistive layer to APV-SRS readout electronics, were investigated
with muons and pions. Detection efficiencies in the 98% range were recorded
with an average pad-multiplicity of ~1.1. The resistive anode resulted in
efficient discharge damping, with few-volt potential drops; discharge
probabilities were ~10^{-7} for muons and 10^{-6} for pions in the double-stage
configuration, at rates of a few kHz/cm^2. These results, together with the
robustness of THGEM electrodes against spark damage and their suitability for
economic production over large areas make THGEM-based detectors highly
competitive compared to the other technologies considered for the SiD-DHCAL.
-
The CMS GEM collaboration is considering Gas Electron Multipliers (GEMs) for
upgrading the CMS forward muon system in the 1.5<|eta|<2.4 endcap region. GEM
detectors can provide precision tracking and fast trigger information. They
would improve the CMS muon trigger and muon momentum resolution and provide
missing redundancy in the high-eta region. Employing a new faster construction
and assembly technique, we built four full-scale Triple-GEM muon detectors for
the inner ring of the first muon endcap station. We plan to install these or
further improved versions in CMS during the first long LHC shutdown in 2013/14
for continued testing. These detectors are designed for the stringent rate and
resolution requirements in the increasingly hostile environments expected at
CMS after the second long LHC shutdown in 2018/19. The new prototypes were
studied in muon/pion beams at the CERN SPS. We discuss our experience with
constructing the new full-scale production prototypes and present preliminary
performance results from the beam test. We also tested smaller Triple-GEM
prototypes with zigzag readout strips with 2 mm pitch in these beams and
measured a spatial resolution of 73 microns. This readout offers a potential
reduction of channel count and consequently electronics cost for this system
while maintaining high spatial resolution.
-
The TOTEM experiment has measured the charged particle pseudorapidity density
dN_{ch}/deta in pp collisions at sqrt{s} = 7 TeV for 5.3<|eta|<6.4 in events
with at least one charged particle with transverse momentum above 40 MeV/c in
this pseudorapidity range. This extends the analogous measurement performed by
the other LHC experiments to the previously unexplored forward eta region. The
measurement refers to more than 99% of non-diffractive processes and to single
and double diffractive processes with diffractive masses above ~3.4 GeV/c^2,
corresponding to about 95% of the total inelastic cross-section. The
dN_{ch}/deta has been found to decrease with |eta|, from 3.84 pm 0.01(stat) pm
0.37(syst) at |eta| = 5.375 to 2.38 pm 0.01(stat) pm 0.21(syst) at |eta| =
6.375. Several MC generators have been compared to data; none of them has been
found to fully describe the measurement.
-
Proton-proton elastic scattering has been measured by the TOTEM experiment at
the CERN Large Hadron Collider at $\sqrt{s} = 7 $ TeV in special runs with the
Roman Pot detectors placed as close to the outgoing beam as seven times the
transverse beam size. The differential cross-section measurements are reported
in the |t|-range of 0.36 to 2.5 GeV^2. Extending the range of data to low t
values from 0.02 to 0.33 GeV^2,and utilizing the luminosity measurements of
CMS, the total proton-proton cross section at sqrt(s) = 7 TeV is measured to be
(98.3 +- 0.2(stat) +- 2.8(syst)) mb.
-
We report on the results of an extensive R&D program aimed at the evaluation
of Thick-Gas Electron Multipliers (THGEM) as potential active elements for
Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad
multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1
cm2 readout pads. The detector is comprised of single- or double-THGEM
multipliers coupled to the pad electrode either directly or via a resistive
anode. Investigations employing standard discrete electronics and the KPiX
readout system have been carried out both under laboratory conditions and with
muons and pions at the CERN RD51 test beam. For detectors having a
charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM
detector reached detection efficiencies above 95%, with pad-hit multiplicity of
1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5
sparks/trigger, depending on the detector structure and gain. Preliminary beam
tests with a WELL hole-structure, closed by a resistive anode, yielded
discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are
presented to reduce charge-spread and pad multiplicity with resistive anodes.
The new method showed good prospects for further evaluation of very thin
THGEM-based detectors as potential active elements for DHCAL, with competitive
performances, simplicity and robustness. Further developments are in course.
-
At present, part of the forward RPC muon system of the CMS detector at the
CERN LHC remains uninstrumented in the high-\eta region. An international
collaboration is investigating the possibility of covering the 1.6 < |\eta| <
2.4 region of the muon endcaps with large-area triple-GEM detectors. Given
their good spatial resolution, high rate capability, and radiation hardness,
these micro-pattern gas detectors are an appealing option for simultaneously
enhancing muon tracking and triggering capabilities in a future upgrade of the
CMS detector. A general overview of this feasibility study will be presented.
The design and construction of small (10\times10 cm2) and full-size trapezoidal
(1\times0.5 m2) triple-GEM prototypes will be described. During detector
assembly, different techniques for stretching the GEM foils were tested.
Results from measurements with x-rays and from test beam campaigns at the CERN
SPS will be shown for the small and large prototypes. Preliminary simulation
studies on the expected muon reconstruction and trigger performances of this
proposed upgraded muon system will be reported.
-
Gas Electron Multipliers (GEM) are an interesting technology under
consideration for the future upgrade of the forward region of the CMS muon
system, specifically in the $1.6<| \eta |<2.4$ endcap region. With a
sufficiently fine segmentation GEMs can provide precision tracking as well as
fast trigger information. The main objective is to contribute to the
improvement of the CMS muon trigger. The construction of large-area GEM
detectors is challenging both from the technological and production aspects. In
view of the CMS upgrade we have designed and built the largest full-size
Triple-GEM muon detector, which is able to meet the stringent requirements
given the hostile environment at the high-luminosity LHC. Measurements were
performed during several test beam campaigns at the CERN SPS in 2010 and 2011.
The main issues under study are efficiency, spatial resolution and timing
performance with different inter-electrode gap configurations and gas mixtures.
In this paper results of the performance of the prototypes at the beam tests
will be discussed.
-
Proton-proton elastic scattering has been measured by the TOTEM experiment at
the CERN Large Hadron Collider at {\surd}s = 7 TeV in dedicated runs with the
Roman Pot detectors placed as close as seven times the transverse beam size
(sbeam) from the outgoing beams. After careful study of the accelerator optics
and the detector alignment, |t|, the square of four-momentum transferred in the
elastic scattering process, has been determined with an uncertainty of d t =
0.1GeV p|t|. In this letter, first results of the differential cross section
are presented covering a |t|-range from 0.36 to 2.5GeV2. The differential
cross-section in the range 0.36 < |t| < 0.47 GeV2 is described by an
exponential with a slope parameter B = (23.6{\pm}0.5stat {\pm}0.4syst)GeV-2,
followed by a significant diffractive minimum at |t| =
(0.53{\pm}0.01stat{\pm}0.01syst)GeV2. For |t|-values larger than ~ 1.5GeV2, the
cross-section exhibits a power law behaviour with an exponent of -7.8_\pm}
0.3stat{\pm}0.1syst. When compared to predictions based on the different
available models, the data show a strong discriminative power despite the small
t-range covered.