In this paper we describe QUBIC, an experiment that takes up the challenge
posed by the detection of primordial gravitational waves with a novel approach,
that combines the sensitivity of state-of-the art bolometric detectors with the
systematic effects control typical of interferometers. The so-called
"self-calibration" is a technique deeply rooted in the interferometric nature
of the instrument and allows us to clean the measured data from instrumental
effects. The first module of QUBIC is a dual band instrument (150 GHz and 220
GHz) that will be deployed in Argentina during the Fall 2018.
-
In this paper we present the design and measured performance of a novel
cryogenic motor based on a superconducting magnetic bearing (SMB). The motor is
tailored for use in millimeter-wave half-wave plate (HWP) polarimeters, where a
HWP is rapidly rotated in front of a polarization analyzer or
polarization-sensitive detector. This polarimetry technique is commonly used in
cosmic microwave background (CMB) polarization studies. The SMB we use is
composed of fourteen yttrium barium copper oxide (YBCO) disks and a contiguous
neodymium iron boron (NdFeB) ring magnet. The motor is a hollow-shaft motor
because the HWP is ultimately installed in the rotor. The motor presented here
has a 100 mm diameter rotor aperture. However, the design can be scaled up to
rotor aperture diameters of approximately 500 mm. Our motor system is composed
of four primary subsystems: (i) the rotor assembly, which includes the NdFeB
ring magnet, (ii) the stator assembly, which includes the YBCO disks, (iii) an
incremental encoder, and (iv) the drive electronics. While the YBCO is cooling
through its superconducting transition, the rotor is held above the stator by a
novel hold and release mechanism (HRM). The encoder subsystem consists of a
custom-built encoder disk read out by two fiber optic readout sensors. For the
demonstration described in this paper, we ran the motor at 50 K and tested
rotation frequencies up to approximately 10 Hz. The feedback system was able to
stabilize the the rotation speed to approximately 0.4%, and the measured rotor
orientation angle uncertainty is less than 0.15 deg. Lower temperature
operation will require additional development activities, which we will
discuss.
-
We describe a space-borne, multi-band, multi-beam polarimeter aiming at a
precise and accurate measurement of the polarization of the Cosmic Microwave
Background. The instrument is optimized to be compatible with the strict budget
requirements of a medium-size space mission within the Cosmic Vision Programme
of the European Space Agency. The instrument has no moving parts, and uses
arrays of diffraction-limited Kinetic Inductance Detectors to cover the
frequency range from 60 GHz to 600 GHz in 19 wide bands, in the focal plane of
a 1.2 m aperture telescope cooled at 40 K, allowing for an accurate extraction
of the CMB signal from polarized foreground emission. The projected CMB
polarization survey sensitivity of this instrument, after foregrounds removal,
is 1.7 {\mu}K$\cdot$arcmin. The design is robust enough to allow, if needed, a
downscoped version of the instrument covering the 100 GHz to 600 GHz range with
a 0.8 m aperture telescope cooled at 85 K, with a projected CMB polarization
survey sensitivity of 3.2 {\mu}K$\cdot$arcmin.