-
High-pressure xenon gas is an attractive detection medium for a variety of
applications in fundamental and applied physics. In this paper we study the
ionization and scintillation detection properties of xenon gas at 10 bar
pressure. For this purpose, we use a source of alpha particles in the NEXT-DEMO
time projection chamber, the large scale prototype of the NEXT-100 neutrinoless
double beta decay experiment, in three different drift electric field
configurations. We measure the ionization electron drift velocity and
longitudinal diffusion, and compare our results to expectations based on
available electron scattering cross sections on pure xenon. In addition, two
types of measurements addressing the connection between the ionization and
scintillation yields are performed. On the one hand we observe, for the first
time in xenon gas, large event-by-event correlated fluctuations between the
ionization and scintillation signals, similar to that already observed in
liquid xenon. On the other hand, we study the field dependence of the average
scintillation and ionization yields. Both types of measurements may shed light
on the mechanism of electron-ion recombination in xenon gas for highly-ionizing
particles. Finally, by comparing the response of alpha particles and electrons
in NEXT-DEMO, we find no evidence for quenching of the primary scintillation
light produced by alpha particles in the xenon gas.
-
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an
electroluminescent time projection chamber that will search for the
neutrinoless double beta decay of Xe-136 using 100 to 150 kg of enriched xenon
gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely,
energy resolution better than 1% FWHM at 2.5 MeV and event topological
reconstruction. In this paper we describe the prototype and its initial
results. A resolution of 1.75% FWHM at 511 keV (which extrapolates to 0.8% FWHM
at 2.5 MeV) was obtained at 10 bar pressure using a gamma-ray calibration
source. Also, a basic study of the event topology along the longitudinal
coordinate is presented, proving that it is possible to identify the distinct
dE/dx of electron tracks in high-pressure xenon using an electroluminescence
TPC.
-
The Neutrino Experiment with a Xenon TPC (NEXT) is intended to investigate
the neutrinoless double beta decay of 136Xe, which requires a severe
suppression of potential backgrounds. An extensive screening and material
selection process is underway for NEXT since the control of the radiopurity
levels of the materials to be used in the experimental set-up is a must for
rare event searches. First measurements based on Glow Discharge Mass
Spectrometry and gamma-ray spectroscopy using ultra-low background germanium
detectors at the Laboratorio Subterr\'aneo de Canfranc (Spain) are described
here. Activity results for natural radioactive chains and other common
radionuclides are summarized, being the values obtained for some materials like
copper and stainless steel very competitive. The implications of these results
for the NEXT experiment are also discussed.
-
We have investigated the possibility of calibrating the PMTs of scintillation
detectors, using the primary scintillation produced by X-rays to induce single
photoelectron response of the PMT. The high-energy tail of this response, can
be approximated to an exponential function, under some conditions. In these
cases, it is possible to determine the average gain for each PMT biasing
voltage from the inverse of the exponent of the exponential fit to the tail,
which can be done even if the background and/or noise cover-up most of the
distribution. We have compared our results with those obtained by the commonly
used single electron response (SER) method, which uses a LED to induce a single
photoelectron response of the PMT and determines the peak position of such
response, relative to the pedestal peak (the electronic noise peak, which
corresponds to 0 photoelectrons). The results of the exponential fit method
agree with those obtained by the SER method when the average number of
photoelectrons reaching the first dynode per light/scintillation pulse is
around 1.0. The SER method has higher precision, while the exponential fit
method has the advantage of being useful in situations where the PMT is already
in situ, being difficult or even impossible to apply the SER method, e.g. in
sealed scintillator/PMT devices.
-
We present the design, data and results from the NEXT prototype for Double
Beta and Dark Matter (NEXT-DBDM) detector, a high-pressure gaseous natural
xenon electroluminescent time projection chamber (TPC) that was built at the
Lawrence Berkeley National Laboratory. It is a prototype of the planned
NEXT-100 $^{136}$Xe neutrino-less double beta decay ($0\nu\beta\beta$)
experiment with the main objectives of demonstrating near-intrinsic energy
resolution at energies up to 662 keV and of optimizing the NEXT-100 detector
design and operating parameters. Energy resolutions of $\sim$1% FWHM for 662
keV gamma rays were obtained at 10 and 15 atm and $\sim$5% FWHM for 30 keV
fluorescence xenon X-rays. These results demonstrate that 0.5% FWHM resolutions
for the 2,459 keV hypothetical neutrino-less double beta decay peak are
realizable. This energy resolution is a factor 7 to 20 better than that of the
current leading $0\nu\beta\beta$ experiments using liquid xenon and thus
represents a significant advancement. We present also first results from a
track imaging system consisting of 64 silicon photo-multipliers recently
installed in NEXT-DBDM that, along with the excellent energy resolution,
demonstrates the key functionalities required for the NEXT-100 $0\nu\beta\beta$
search.
-
In this Technical Design Report (TDR) we describe the NEXT-100 detector that
will search for neutrinoless double beta decay (bbonu) in Xe-136 at the
Laboratorio Subterraneo de Canfranc (LSC), in Spain. The document formalizes
the design presented in our Conceptual Design Report (CDR): an
electroluminescence time projection chamber, with separate readout planes for
calorimetry and tracking, located, respectively, behind cathode and anode. The
detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or
100 kg at 10 bar. This option builds in the capability to increase the total
isotope mass by 50% while keeping the operating pressure at a manageable level.
The readout plane performing the energy measurement is composed of Hamamatsu
R11410-10 photomultipliers, specially designed for operation in low-background,
xenon-based detectors. Each individual PMT will be isolated from the gas by an
individual, pressure resistant enclosure and will be coupled to the sensitive
volume through a sapphire window. The tracking plane consists in an array of
Hamamatsu S10362-11-050P MPPCs used as tracking pixels. They will be arranged
in square boards holding 64 sensors (8 times8) with a 1-cm pitch. The inner
walls of the TPC, the sapphire windows and the boards holding the MPPCs will be
coated with tetraphenyl butadiene (TPB), a wavelength shifter, to improve the
light collection.