-
The electron shakeoff of 19F and 35Cl atoms resulting from the \b{eta}+ decay
of 19Ne+ and 35Ar+ ions has been investigated using a Paul trap coupled to a
time of flight recoil-ion spectrometer. The charge-state distributions of the
recoiling daughter nuclei were compared to theoretical calculations based on
the sudden approximation and accounting for subsequent Auger processes. The
excellent agreement obtained for 35Cl is not reproduced in 19F. The shortcoming
is attributed to the inaccuracy of the independent particle model employed to
calculate the primary shakeoff probabilities in systems with rather low atomic
numbers. This calls for more elaborate calculations, including explicitly the
electron-electron correlations.
-
SuperNEMO is a double-$\beta$ decay experiment, which will employ the
successful tracker-calorimeter technique used in the recently completed NEMO-3
experiment. SuperNEMO will implement 100 kg of double-$\beta$ decay isotope,
reaching a sensitivity to the neutrinoless double-$\beta$ decay
($0\nu\beta\beta$) half-life of the order of $10^{26}$ yr, corresponding to a
Majorana neutrino mass of 50-100 meV. One of the main goals and challenges of
the SuperNEMO detector development programme has been to reach a calorimeter
energy resolution, $\Delta$E/E, around 3%/$sqrt(E)$(MeV) $\sigma$, or
7%/$sqrt(E)$(MeV) FWHM (full width at half maximum), using a calorimeter
composed of large volume plastic scintillator blocks coupled to photomultiplier
tubes. We describe the R\&D programme and the final design of the SuperNEMO
calorimeter that has met this challenging goal.
-
The BiPo-3 detector, running in the Canfranc Underground Laboratory
(Laboratorio Subterr\'aneo de Canfranc, LSC, Spain) since 2013, is a
low-radioactivity detector dedicated to measuring ultra low natural
radionuclide contaminations of $^{208}$Tl ($^{232}$Th chain) and $^{214}$Bi
($^{238}$U chain) in thin materials. The total sensitive surface area of the
detector is 3.6 m$^2$. The detector has been developed to measure radiopurity
of the selenium double $\beta$-decay source foils of the SuperNEMO experiment.
In this paper the design and performance of the detector, and results of the
background measurements in $^{208}$Tl and $^{214}$Bi, are presented, and
validation of the BiPo-3 measurement with a calibrated aluminium foil is
discussed. Results of the $^{208}$Tl and $^{214}$Bi activity measurements of
the first enriched $^{82}$Se foils of the double $\beta$-decay SuperNEMO
experiment are reported. The sensitivity of the BiPo-3 detector for the
measurement of the SuperNEMO $^{82}$Se foils is $\mathcal{A}$($^{208}$Tl) $<2$
$\mu$Bq/kg (90\% C.L.) and $\mathcal{A}$($^{214}$Bi) $<140$ $\mu$Bq/kg (90\%
C.L.) after 6 months of measurement.
-
We report the results of a first experimental search for lepton number
violation by four units in the neutrinoless quadruple-$\beta$ decay of
$^{150}$Nd using a total exposure of $0.19$ kg$\cdot$y recorded with the NEMO-3
detector at the Modane Underground Laboratory (LSM). We find no evidence of
this decay and set lower limits on the half-life in the range
$T_{1/2}>(1.1-3.2)\times10^{21}$ y at the $90\%$ CL, depending on the model
used for the kinematic distributions of the emitted electrons.
-
The NEMO-3 experiment measured the half-life of the $2\nu\beta\beta$ decay
and searched for the $0\nu\beta\beta$ decay of $^{116}$Cd. Using $410$ g of
$^{116}$Cd installed in the detector with an exposure of $5.26$ y,
($4968\pm74$) events corresponding to the $2\nu\beta\beta$ decay of $^{116}$Cd
to the ground state of $^{116}$Sn have been observed with a signal to
background ratio of about $12$. The half-life of the $2\nu\beta\beta$ decay has
been measured to be $
T_{1/2}^{2\nu}=[2.74\pm0.04\mbox{(stat.)}\pm0.18\mbox{(syst.)}]\times10^{19}$
y. No events have been observed above the expected background while searching
for $0\nu\beta\beta$ decay. The corresponding limit on the half-life is
determined to be $T_{1/2}^{0\nu} \ge 1.0 \times 10^{23}$ y at the $90$ % C.L.
which corresponds to an upper limit on the effective Majorana neutrino mass of
$\langle m_{\nu} \rangle \le 1.4-2.5$ eV depending on the nuclear matrix
elements considered. Limits on other mechanisms generating $0\nu\beta\beta$
decay such as the exchange of R-parity violating supersymmetric particles,
right-handed currents and majoron emission are also obtained.
-
The NEMO-3 detector, which had been operating in the Modane Underground
Laboratory from 2003 to 2010, was designed to search for neutrinoless double
$\beta$ ($0\nu\beta\beta$) decay. We report final results of a search for
$0\nu\beta\beta$ decays with $6.914$ kg of $^{100}$Mo using the entire NEMO-3
data set with a detector live time of $4.96$ yr, which corresponds to an
exposure of 34.3 kg$\cdot$yr. We perform a detailed study of the expected
background in the $0\nu\beta\beta$ signal region and find no evidence of
$0\nu\beta\beta$ decays in the data. The level of observed background in the
$0\nu\beta\beta$ signal region $[2.8-3.2]$ MeV is $0.44 \pm 0.13$ counts/yr/kg,
and no events are observed in the interval $[3.2-10]$ MeV. We therefore derive
a lower limit on the half-life of $0\nu\beta\beta$ decays in $^{100}$Mo of
$T_{1/2}(0\nu\beta\beta)> 1.1 \times 10^{24}$ yr at the $90\%$ Confidence
Level, under the hypothesis of light Majorana neutrino exchange. Depending on
the model used for calculating nuclear matrix elements, the limit for the
effective Majorana neutrino mass lies in the range $\langle m_{\nu} \rangle <
0.33$--$0.62$ eV. We also report constraints on other lepton-number violating
mechanisms for $0\nu\beta\beta$ decays.
-
The experimental achievements and the results obtained so far with the
LPCTrap device installed at GANIL are presented. The apparatus is dedicated to
the study of the weak interaction at low energy by means of precise
measurements of the BETA-NU angular correlation parameter in nuclear BETA
decays. So far, the data collected with three isotopes have enabled to
determine, for the first time, the charge state distributions of the recoiling
ions, induced by shakeoff process. The analysis is presently refined to deduce
the correlation parameters, with the potential of improving both the constraint
deduced at low energy on exotic tensor currents (6He1+) and the precision on
the V u d element of the quark-mixing matrix (35Ar1+ and 19Ne1+) deduced from
the mirror transitions dataset.
-
This Letter reports results from the NEMO-3 experiment based on an exposure
of 1275 days with 661g of 130Te in the form of enriched and natural tellurium
foils. The double beta decay rate of 130Te is found to be greater than zero
with a significance of 7.7 standard deviations and the half-life is measured to
be T1/2 = (7.0 +/- 0.9(stat) +/- 1.1(syst)) x 10^{20} yr. This represents the
most precise measurement of this half-life yet published and the first
real-time observation of this decay.
-
The possibility to probe new physics scenarios of light Majorana neutrino
exchange and right-handed currents at the planned next generation neutrinoless
double beta decay experiment SuperNEMO is discussed. Its ability to study
different isotopes and track the outgoing electrons provides the means to
discriminate different underlying mechanisms for the neutrinoless double beta
decay by measuring the decay half-life and the electron angular and energy
distributions.
-
The development of BiPo detectors is dedicated to the measurement of
extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO
double beta decay source foils. A modular prototype, called BiPo-1, with 0.8
$m^2$ of sensitive surface area, has been running in the Modane Underground
Laboratory since February, 2008. The goal of BiPo-1 is to measure the different
components of the background and in particular the surface radiopurity of the
plastic scintillators that make up the detector. The first phase of data
collection has been dedicated to the measurement of the radiopurity in
$^{208}$Tl. After more than one year of background measurement, a surface
activity of the scintillators of $\mathcal{A}$($^{208}$Tl) $=$ 1.5
$\mu$Bq/m$^2$ is reported here. Given this level of background, a larger BiPo
detector having 12 m$^2$ of active surface area, is able to qualify the
radiopurity of the SuperNEMO selenium double beta decay foils with the required
sensitivity of $\mathcal{A}$($^{208}$Tl) $<$ 2 $\mu$Bq/kg (90% C.L.) with a six
month measurement.
-
The background induced by radioactive impurities of $^{208}\rm Tl$ and
$^{214}\rm Bi$ in the source of the double beta experiment NEMO-3 has been
investigated. New methods of data analysis which decrease the background from
the above mentioned contamination are identified. The techniques can also be
applied to other double beta decay experiments capable of measuring
independently the energies of the two electrons.