On the wake of the results obtained so far at the SPARC\_LAB test-facility at
the Laboratori Nazionali di Frascati (Italy), we are currently investigating
the possibility to design and build a new multi-disciplinary user-facility,
equipped with a soft X-ray Free Electron Laser (FEL) driven by a $\sim$1 GeV
high brightness linac based on plasma accelerator modules. This design study is
performed in synergy with the EuPRAXIA design study. In this paper we report
about the recent progresses in the on going design study of the new facility.
-
Recent investigations of RF copper structures operated at cryogenic
temperatures performed by a SLAC-UCLA collaboration have shown a dramatic
increase in the maximum surface electric field, to 500 MV/m. We examine use of
these fields to enable very high field cryogenic photoinjectors that can attain
over an order of magnitude increase in peak electron beam brightness. We
present beam dynamics studies relevant to X-ray FEL injectors, using
start-to-end simulations that show the high brightness and low emittance of
this source enables operation of a compact FEL reaching a photon energy of 80
keV. The preservation of beam brightness in compression, exploiting
micro-bunching techniques is discussed. While the gain in brightness at high
field is due to increase of the emission current density, further increases in
brightness due to lowering of the intrinsic cathode emittance in cryogenic
operation are also enabled. While the original proposal for this type of
cryogenic, ultra-high field photoinjector has emphasized S-band designs, there
are numerous potential advantages that may be conferred by operation in C-band.
We examine issues related to experimental implementation in C-band, and
expected performance of this type of device in a future hard X-ray FEL such as
MaRIE.
-
Plasma wake-field acceleration experiments are performed at the SPARC LAB
test facility by using a gas-filled capillary plasma source composed of a
dielectric capillary. The electron can reach GeV energy in a few centimeters,
with an accelerating gradient orders of magnitude larger than provided by
conventional techniques. In this acceleration scheme, wake fields produced by
passing electron beams through dielectric structures can determine a strong
beam instability that represents an important hurdle towards the capability to
focus high-current electron beams in the transverse plane. For these reasons,
the estimation of the transverse wakefield amplitudes assumes a fundamental
role in the implementation of the plasma wake-field acceleration. In this work,
it presented a study to investigate which parameters affect the wake-field
formation inside a cylindrical dielectric structure, both the capillary
dimensions and the beam parameters, and it is introduced a quantitative
evaluation of the longitudinal and transverse electric fields.