-
This paper describes the hardware and operations of the Neutrinos at the Main
Injector (NuMI) beam at Fermilab. It elaborates on the design considerations
for the beam as a whole and for individual elements. The most important design
details of individual components are described. Beam monitoring systems and
procedures, including the tuning and alignment of the beam and NuMI long-term
performance, are also discussed.
-
The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the
proton-proton interaction region in the LHCb experiment. The performance of the
detector during the first years of its physics operation is reviewed. The
system is operated in vacuum, uses a bi-phase CO2 cooling system, and the
sensors are moved to 7 mm from the LHC beam for physics data taking. The
performance and stability of these characteristic features of the detector are
described, and details of the material budget are given. The calibration of the
timing and the data processing algorithms that are implemented in FPGAs are
described. The system performance is fully characterised. The sensors have a
signal to noise ratio of approximately 20 and a best hit resolution of 4
microns is achieved at the optimal track angle. The typical detector occupancy
for minimum bias events in standard operating conditions in 2011 is around
0.5%, and the detector has less than 1% of faulty strips. The proximity of the
detector to the beam means that the inner regions of the n+-on-n sensors have
undergone space-charge sign inversion due to radiation damage. The VELO
performance parameters that drive the experiment's physics sensitivity are also
given. The track finding efficiency of the VELO is typically above 98% and the
modules have been aligned to a precision of 1 micron for translations in the
plane transverse to the beam. A primary vertex resolution of 13 microns in the
transverse plane and 71 microns along the beam axis is achieved for vertices
with 25 tracks. An impact parameter resolution of less than 35 microns is
achieved for particles with transverse momentum greater than 1 GeV/c.
-
The LHCb RICH1 detector uses hybrid photon detectors (HPDs) as its optical
sensors. A calibration system has been constructed to provide corrections for
distortions that are primarily due to external magnetic fields. We describe
here the system design, construction, operation and performance.
-
We report constraints on antineutrino oscillation parameters that were
obtained by using the two MINOS detectors to measure the 7% muon antineutrino
component of the NuMI neutrino beam. In the Far Detector, we select 130 events
in the charged-current muon antineutrino sample, compared to a prediction of
136.4 +/- 11.7(stat) ^{+10.2}_{-8.9}(syst) events under the assumption
|dm2bar|=2.32x10^-3 eV^2, snthetabar=1.0. Assuming no oscillations occur at the
Near Detector baseline, a fit to the two-flavor oscillation approximation
constrains |dm2bar|<3.37x10^-3 eV^2 at the 90% confidence level with
snthetabar=1.0.
-
This letter reports the first direct observation of muon antineutrino
disappearance. The MINOS experiment has taken data with an accelerator beam
optimized for muon antineutrino production, accumulating an exposure of
$1.71\times 10^{20}$ protons on target. In the Far Detector, 97 charged current
muon antineutrino events are observed. The no-oscillation hypothesis predicts
156 events and is excluded at $6.3\sigma$. The best fit to oscillation yields
$\Delta
\bar{m}^{2}=(3.36^{+0.46}_{-0.40}\textrm{(stat.)}\pm0.06\textrm{(syst.)})\times
10^{-3}\,\eV^{2}$,
$\sin^{2}(2\bar{\theta})=0.86^{+0.11}_{-0.12}\textrm{(stat.)}\pm0.01\textrm{(syst.)}$.
The MINOS muon neutrino and muon antineutrino measurements are consistent at
the 2.0% confidence level, assuming identical underlying oscillation
parameters.
-
We report the results of a search for $\nu_{e}$ appearance in a $\nu_{\mu}$
beam in the MINOS long-baseline neutrino experiment. With an improved analysis
and an increased exposure of $8.2\times10^{20}$ protons on the NuMI target at
Fermilab, we find that $2\sin^2(\theta_{23})\sin^2(2\theta_{13})<0.12\ (0.20)$
at 90% confidence level for $\delta\mathord{=}0$ and the normal (inverted)
neutrino mass hierarchy, with a best fit of
$2\sin^2(\theta_{23})\sin^2(2\theta_{13})\,\mathord{=}\,0.041^{+0.047}_{-0.031}\
(0.079^{+0.071}_{-0.053})$. The $\theta_{13}\mathord{=}0$ hypothesis is
disfavored by the MINOS data at the 89% confidence level.
-
Results are reported from a search for active to sterile neutrino
oscillations in the MINOS long-baseline experiment, based on the observation of
neutral-current neutrino interactions, from an exposure to the NuMI neutrino
beam of $7.07\times10^{20}$ protons on target. A total of 802 neutral-current
event candidates is observed in the Far Detector, compared to an expected
number of $754\pm28\rm{(stat.)}\pm{37}\rm{(syst.)}$ for oscillations among
three active flavors. The fraction $f_s$ of disappearing \numu that may
transition to $\nu_s$ is found to be less than 22% at the 90% C.L.
-
Measurements of neutrino oscillations using the disappearance of muon
neutrinos from the Fermilab NuMI neutrino beam as observed by the two MINOS
detectors are reported. New analysis methods have been applied to an enlarged
data sample from an exposure of $7.25 \times 10^{20}$ protons on target. A fit
to neutrino oscillations yields values of $|\Delta m^2| =
(2.32^{+0.12}_{-0.08})\times10^{-3}$\,eV$^2$ for the atmospheric mass splitting
and $\rm \sin^2\!(2\theta) > 0.90$ (90%\,C.L.) for the mixing angle. Pure
neutrino decay and quantum decoherence hypotheses are excluded at 7 and 9
standard deviations, respectively.
-
We searched for a sidereal modulation in the MINOS far detector neutrino
rate. Such a signal would be a consequence of Lorentz and CPT violation as
described by the Standard-Model Extension framework. It also would be the first
detection of a perturbative effect to conventional neutrino mass oscillations.
We found no evidence for this sidereal signature and the upper limits placed on
the magnitudes of the Lorentz and CPT violating coefficients describing the
theory are an improvement by factors of $20-510$ over the current best limits
found using the MINOS near detector.
-
The nitrogen fluorescence induced in air is used to detect ultra-high energy
cosmic rays and to measure their energy. The precise knowledge of the absolute
fluorescence yield is the key quantity to improve the accuracy on the cosmic
ray energy. The total yield has been measured in dry air using a 90Sr source
and a [300-430 nm] filter. The fluorescence yield in air is 4.23 $\pm$ 0.20
photons per meter when normalized to 760 mmHg, 15 degrees C and with an
electron energy of 0.85 MeV. This result is consistent with previous
experiments made at various energies, but with an accuracy improved by a factor
of about 3. For the first time, the absolute continuous spectrum of nitrogen
excited by 90Sr electrons has also been measured with a spectrometer. Details
of this experiment are given in one of the author's PhD thesis [32].