-
Prompt production of charmonium $\chi_{c0}$, $\chi_{c1}$ and $\chi_{c2}$
mesons is studied using proton-proton collisions at the LHC at a centre-of-mass
energy of $\sqrt{s}=7$TeV. The $\chi_{c}$ mesons are identified through their
decay to $J/\psi\gamma$, with $J/\psi\to\mu^+\mu^-$ using photons that
converted in the detector. A data sample, corresponding to an integrated
luminosity of $1.0\mathrm{fb}^{-1}$ collected by the LHCb detector, is used to
measure the relative prompt production rate of $\chi_{c1}$ and $\chi_{c2}$ in
the rapidity range $2.0<y<4.5$ as a function of the $J/\psi$ transverse
momentum from 3 to 20 GeV$/c$. First evidence for $\chi_{c0}$ meson production
at a high-energy hadron collider is also presented.
-
The CUORE experiment, a ton-scale cryogenic bolometer array, recently began
operation at the Laboratori Nazionali del Gran Sasso in Italy. The array
represents a significant advancement in this technology, and in this work we
apply it for the first time to a high-sensitivity search for a
lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay.
Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an
effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the
region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we
find no evidence for neutrinoless double-beta decay. The median statistical
sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic
uncertainties, we place a lower limit on the decay half-life of
$T^{0\nu}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining
this result with those of two earlier experiments, Cuoricino and CUORE-0, we
find $T^{0\nu}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is
the most stringent limit to date on this decay. Interpreting this result as a
limit on the effective Majorana neutrino mass, we find $m_{\beta\beta}<(110 -
520)$ meV, where the range reflects the nuclear matrix element estimates
employed.
-
The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso,
Italy, is the first large array of enriched scintillating cryogenic detectors
for the investigation of $^{82}$Se neutrinoless double-beta decay
(0$\nu\beta\beta$). CUPID-0 aims at measuring a background index in the region
of interest (RoI) for 0$\nu\beta\beta$ at the level of 10$^{-3}$ c/keV/kg/y,
the lowest value ever measured using cryogenic detectors. This result can be
achieved by a state of the art technology for background suppression and
thorough protocols and procedures for detector preparation and construction. In
this paper, the different phases of the detector design and construction will
be presented, from the material selection (for the absorber production) to the
new and innovative detector structure. The successful construction of the
detector lead to promising detector performance which are here preliminarily
discussed
-
We report the result of the search for neutrinoless double beta decay of
$^{82}$Se obtained with CUPID-0, the first large array of scintillating
Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We
observe no signal in a 1.83 kg$\cdot$yr $^{82}$Se exposure and we set the most
stringent lower limit on the \onu $^{82}$Se half-life T$^{0\nu}_{1/2}>$
2.4$\cdot \mathrm{10}^{24}$ yr (90\% C.I.), which corresponds to an effective
Majorana neutrino mass m$_{\beta\beta} <$ (376-770) meV depending on the
nuclear matrix element calculations. The heat-light readout provides a powerful
tool for the rejection of \al\ particles and allows to suppress the background
in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$\cdot$10$^{-3}$\ckky,
an unprecedented level for this technique.
-
TeO2 bolometers have been used for many years to search for neutrinoless
double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently
published the most sensitive limit on the half-life, $T_{1/2}^{0\nu} > 1.5
\times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on
the effective Majorana mass of the neutrino. While it makes CUORE a
world-leading experiment looking for neutrinoless double beta decay, it is not
the only study that CUORE will contribute to in the field of nuclear and
particle physics. As already done over the years with many small-scale
experiments, CUORE will investigate both rare decays (such as the two-neutrino
double beta decay of 130-Te and the hypothesized electron capture in 123-Te),
and rare processes (e.g., dark matter and axion interactions). This paper
describes some of the achievements of past experiments that used TeO2
bolometers, and perspectives for CUORE.
-
Bolometric experiments searching for rare events usually require an extremely
low radioactive background to prevent spurious signals from mimicking those of
interest, spoiling the sensitivity of the apparatus. In such contexts,
radioactive sources cannot be used to produce a known signal to calibrate the
measured energy spectrum during data taking. In this paper we present an
instrument designed to generate ultra-stable and very precise calibrating
pulse, which can be used to stabilize the response of bolometers during data
taking. The instrument is characterized by the presence of multi-outputs, a
completely programmable pulse width and amplitude and a dedicated daisy-chained
optical trigger line. It can be fully controlled and monitored remotely via CAN
bus protocol. An energy resolution of the order of 20 eV FWHM at 1 MeV (2 eV
FWHM at 10 keV) and a thermal stability of the order of 0.1 ppm/{\deg}C have
been achieved. The device can also provide an adjustable power to compensate
the low frequency thermal fluctuations that typically occur in cryogenic
experiments.
-
We have performed a search for neutrinoless $\beta^{+}\hspace{-0.2em}EC$
decay of $^{120}$Te using the final CUORE-0 data release. We describe a new
analysis method for the simultaneous fit of signatures with different event
topology, and of data subsets with different signal efficiency, obtaining a
limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$
CI. Combining this with results from Cuoricino, a predecessor experiment, we
obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$
yr at $90\%$ CI.
-
The paper describes the Faraday room that shields the CUORE experiment
against electromagnetic fields, from 50 Hz up to high frequency. Practical
contraints led to choose panels made of light shielding materials. The seams
between panels were optimized with simulations to minimize leakage.
Measurements of shielding performance show attenuation of a factor 15 at 50 Hz,
and a factor 1000 above 1 KHz up to about 100 MHz.
-
This paper reports on the development of a technology involving
$^{100}$Mo-enriched scintillating bolometers, compatible with the goals of
CUPID, a proposed next-generation bolometric experiment to search for
neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality,
radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been
produced and used to develop high performance single detector modules based on
0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of
the lithium molybdate detectors near the $Q$-value of the double-beta
transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the
$\alpha$-induced dominant background above 2.6~MeV is better than 8$\sigma$.
Less than 10~$\mu$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in
the crystals is ensured by boule recrystallization. The potential of
$^{100}$Mo-enriched scintillating bolometers to perform high sensitivity
double-beta decay searches has been demonstrated with only 10~kg$\times$d
exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been
measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$
0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and
detector technologies favor lithium molybdate, which has been selected for the
ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of
$^{100}$Mo.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to
search for neutrinoless double beta decay of 130Te with an array of 988 TeO2
bolometers operating at temperatures around 10 mK. The experiment is currently
being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The
goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay
half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main
issue to be addressed to accomplish this aim is the rate of background events
in the region of interest, which must not be higher than
10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation,
based on results from a campaign of material screening, radioassays, and
bolometric measurements, to evaluate the expected background. This was used
over the years to guide the construction strategies of the experiment and we
use it here to project a background model for CUORE. In this paper we report
the results of our study and our expectations for the background rate in the
energy region where the peak signature of neutrinoless double beta decay of
130Te is expected.
-
CUORE is a tonne-scale cryogenic detector operating at the Laboratori
Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to
search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable
to search for low energy rare events such as solar axions or WIMP scattering,
thanks to its ultra-low background and large target mass. However, to conduct
such sensitive searches requires improving the energy threshold to 10 keV. In
this paper, we describe the analysis techniques developed for the low energy
analysis of CUORE-like detectors, using the data acquired from November 2013 to
March 2015 by CUORE-0, a single-tower prototype designed to validate the
assembly procedure and new cleaning techniques of CUORE. We explain the energy
threshold optimization, continuous monitoring of the trigger efficiency, data
and event selection, and energy calibration at low energies in detail. We also
present the low energy background spectrum of CUORE-0 below 60keV. Finally, we
report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0
energy threshold and background, as well as an estimate of the uncertainty on
the nuclear quenching factor from nuclear recoils in CUORE-0.
-
We report a study of the CUORE sensitivity to neutrinoless double beta
($0\nu\beta\beta$) decay. We used a Bayesian analysis based on a toy Monte
Carlo (MC) approach to extract the exclusion sensitivity to the
$0\nu\beta\beta$ decay half-life ($T_{1/2}^{0\nu}$) at $90\%$ credibility
interval (CI) -- i.e. the interval containing the true value of
$T_{1/2}^{0\nu}$ with $90\%$ probability -- and the $3 \sigma$ discovery
sensitivity. We consider various background levels and energy resolutions, and
describe the influence of the data division in subsets with different
background levels. If the background level and the energy resolution meet the
expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of
$2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of
live time. Under the same conditions, the discovery sensitivity after $3$
months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr,
respectively.
-
Recently there is a flourishing and notable interest in the crystalline
scintillator material sodium iodide (NaI) as target for direct dark matter
searches. This is mainly driven by the long-reigning contradicting situation in
the dark matter sector: the positive evidence for the detection of a dark
matter modulation signal claimed by the DAMA/LIBRA collaboration is (under
so-called standard assumptions) inconsistent with the null-results reported by
most of the other direct dark matter experiments. We present the results of a
first prototype detector using a new experimental approach in comparison to
conventional single-channel NaI scintillation light detectors: a NaI crystal
operated as a scintillating calorimeter at milli-Kelvin temperatures
simultaneously providing a phonon (heat) plus scintillation light signal and
particle discrimination on an event-by-event basis. We evaluate energy
resolution, energy threshold and further performance parameters of this
prototype detector developed within the COSINUS R&D project.
-
HOLMES is a new experiment aiming at directly measuring the neutrino mass
with a sensitivity below 2 eV. HOLMES will perform a calorimetric measurement
of the energy released in the decay of $^{163}$Ho. The calorimetric measurement
eliminates systematic uncertainties arising from the use of external beta
sources, as in experiments with spectrometers. This measurement was proposed in
1982 by A. De Rujula and M. Lusignoli, but only recently the detector
technological progress has allowed to design a sensitive experiment. HOLMES
will deploy a large array of low temperature microcalorimeters with implanted
$^{163}$Ho nuclei. HOLMES, besides being an important step forward in the
direct neutrino mass measurement with a calorimetric approach, will also
establish the potential of this approach to extend the sensitivity down to 0.1
eV and lower. In its final configuration HOLMES will collect about $3\cdot
10^{13}$ decays with 1000 detectors characterized by an instrumental energy
resolution of the order of few eV and a time resolution of few microseconds. To
embed the $^{163}$Ho into the gold absorbers a custom mass separator ion
implanter is being developed. The detectors used for the HOLMES experiment will
be Mo/Cu bilayers TESs (Transition Edge Sensors) on SiN$_x$ membrane with gold
absorbers. Microwave multiplexed rf-SQUIDs are the best available technique to
read out large array of such detectors. An extensive R&D activity is in
progress in order to maximize the multiplexing factor while preserving the
performances of the individual detectors. The current activities are focused on
the the single detector performances optimization and on the $^{163}$Ho isotope
production and embedding. A preliminary measurement of a sub-array of $4\times
16$ detectors is planned late in 2017. In this contribution we present the
HOLMES project with its technical challenges, its status and perspectives.
-
We report on the measurement of the two-neutrino double beta decay half-life
of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of
TeO$_2$, the half-life is determined to be $T_{1/2}^{2\nu}$ = [8.2 $\pm$ 0.2
(stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a
detailed reconstruction of the sources responsible for the CUORE-0 counting
rate, with a specific study of those contributing to the $^{130}$Te
neutrinoless double beta decay region of interest.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton
scale bolometric experiment devoted to the search of the neutrinoless
double-beta decay (0{\nu}\b{eta}\b{eta}) in 130Te. The CUORE detector consists
of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE
demonstrator: it has been built to test the performance of the upcoming CUORE
experiment and represents the largest 130Te bolometric setup ever operated.
CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from
2013 to 2015. The final CUORE-0 analysis on 0{\nu}\b{eta}\b{eta} and the
corresponding detector performance are presented. The present status of the
CUORE experiment, now in its final construction and commissioning phase, are
discussed. The results from assembly of the detector and the commissioning of
the cryostat are reported.
-
A new generation of cryogenic light detectors exploiting Neganov-Luke effect
to enhance the thermal signal has been used to detect the Cherenkov light
emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism
a high significance event-by-event discrimination between alpha and beta/gamma
interactions at the $^{130}$Te neutrino-less double beta decay Q-value -
(2527.515 $\pm$ 0.013) keV - has been demonstrated. This measurement opens the
possibility of drastically reducing the background in cryogenic experiments
based on TeO$_{2}$.
-
At present the results in the field of direct dark matter search are in
tension: the positive claim of DAMA/LIBRA versus null results from other
experiments. However, the comparison of the results of different experiments
involves model dependencies, in particular because of the different target
materials in use. The COSINUS R&D project aims to operate NaI as a cryogenic
calorimeter. Such a detector would not only allow for a direct comparison to
DAMA/LIBRA, but would also provide a low(er) nuclear recoil threshold and
particle discrimination.
-
The LHCb detector will be upgraded to make more efficient use of the
available luminosity at the LHC in Run III and extend its potential for
discovery. The Ring Imaging Cherenkov detectors are key components of the LHCb
detector for particle identification. In this paper we describe the setup and
the results of tests in a charged particle beam, carried out to assess
prototypes of the upgraded opto-electronic chain from the Multi-Anode PMT
photosensor to the readout and data acquisition system.
-
We present the performances of two 92% enriched $^{130}$TeO$_2$ crystals
operated as thermal bolometers in view of a next generation experiment to
search for neutrinoless double beta decay of $^{130}$Te. The crystals, 435 g
each, show an energy resolution, evaluated at the 2615 keV $\gamma$-line of
$^{208}$Tl, of 6.5 and 4.3 keV FWHM. The only observable internal radioactive
contamination arises from $^{238}$U (15 and 8 $\mu$Bq/kg, respectively). The
internal activity of the most problematic nuclei for neutrinoless double beta
decay, $^{226}$Ra and $^{228}$Th, are both evaluated as $<$3.1 $\mu$Bq/kg for
one crystal and $<$2.3 $\mu$Bq/kg for the second. Thanks to the readout of the
weak Cherenkov light emitted by $\beta/\gamma$ particles by means of
Neganov-Luke bolometric light detectors we were able to perform an
event-by-event identification of $\beta/\gamma$ events with a 95% acceptance
level, while establishing a rejection factor of 98.21% and 99.99% for $\alpha$
particles.
-
The CUORE experiment will search for neutrinoless double-beta decay of
$^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers.
CUORE-0, the first tower assembled according to the CUORE procedures, was built
and commissioned at Laboratori Nazionali del Gran Sasso, and took data from
March 2013 to March 2015. In this paper we describe the design, construction
and operation of the CUORE-0 experiment, with an emphasis on the improvements
made over a predecessor experiment, Cuoricino. In particular, we demonstrate
with CUORE-0 data that the design goals of CUORE are within reach.
-
For the first time, a cadmium tungstate crystal scintillator enriched in
$^{116}$Cd has been succesfully tested as a scintillating bolometer. The
measurement was performed above ground at a temperature of 18 mK. The crystal
mass was 34.5 g and the enrichment level ~82 %. Despite a substantial pile-up
effect due to above-ground operation, the detector demonstrated a high energy
resolution (2-7 keV FWHM in 0.2-2.6 MeV $\gamma$ energy range), a powerful
particle identification capability and a high level of internal radiopurity.
These results prove that cadmium tungstate is an extremely promising detector
material for a next-generation neutrinoless double-beta decay bolometric
experiment, like that proposed in the CUPID project (CUORE Upgrade with
Particle IDentification).
-
The R&D activity performed during the last years proved the potential of ZnSe
scintillating bolometers to the search for neutrino-less double beta decay,
motivating the realization of the first large-mass experiment based on this
technology: CUPID-0. The isotopic enrichment in $^{82}$Se, the Zn$^{82}$Se
crystals growth, as well as the light detectors production have been
accomplished, and the experiment is now in construction at Laboratori Nazionali
del Gran Sasso (Italy). In this paper we present the results obtained testing
the first three Zn$^{82}$Se crystals operated as scintillating bolometers, and
we prove that their performance in terms of energy resolution, background
rejection capability and intrinsic radio-purity complies with the requirements
of CUPID-0.
-
We describe in detail the methods used to obtain the lower bound on the
lifetime of neutrinoless double-beta ($0\nu\beta\beta$) decay in $^{130}$Te and
the associated limit on the effective Majorana mass of the neutrino using the
CUORE-0 detector. CUORE-0 is a bolometric detector array located at the
Laboratori Nazionali del Gran Sasso that was designed to validate the
background reduction techniques developed for CUORE, a next-generation
experiment scheduled to come online in 2016. CUORE-0 is also a competitive
$0\nu\beta\beta$ decay search in its own right and functions as a platform to
further develop the analysis tools and procedures to be used in CUORE. These
include data collection, event selection and processing, as well as an
evaluation of signal efficiency. In particular, we describe the amplitude
evaluation, thermal gain stabilization, energy calibration methods, and the
analysis event selection used to create our final $0\nu\beta\beta$ decay search
spectrum. We define our high level analysis procedures, with emphasis on the
new insights gained and challenges encountered. We outline in detail our
fitting methods near the hypothesized $0\nu\beta\beta$ decay peak and catalog
the main sources of systematic uncertainty. Finally, we derive the
$0\nu\beta\beta$ decay half-life limits previously reported for CUORE-0,
$T^{0\nu}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino
limit, $T^{0\nu}_{1/2}>4.0\times10^{24}$ yr.
-
The R&D project COSINUS (Cryogenic Observatory for SIgnatures seen in
Next-generation Underground Searches) aims to develop a cryogenic scintillating
calorimeter using NaI as target crystal for direct darkmatter search. Dark
matter particles interacting with the detector material generate both a phonon
signal and scintillation light. While the phonon signal provides a precise
determination of the deposited energy, the simultaneously measured
scintillation light allows for a particle identification on an event-by-event
basis, a powerful tool to study material-dependent interactions, and to
suppress backgrounds. Using the same target material as the DAMA/LIBRA
collaboration, the COSINUS technique may offer a unique possibility to
investigate and contribute information to the presently controversial situation
in the dark matter sector. We report on the dedicated design planned for the
NaI proof-of-principle detector and the objectives of using this detection
technique in the light of direct dark matter detection.