• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • The STEREO Experiment (1804.09052)

    N. Allemandou, H. Almazán, P. del Amo Sanchez, L. Bernard, C. Bernard, A. Blanchet, A. Bonhomme, G. Bosson, O. Bourrion, J. Bouvier, C. Buck, V. Caillot, M. Chala, P. Champion, P. Charon, A. Collin, P. Contrepois, G. Coulloux, G. Deleglise, W. El Kanawati, J. Favier, S. Fuard, I. Gomes Monteiro, B. Gramlich, J. Haser, V. Helaine, M. Heusch, M. Jentschel, F. Kandzia, G. Konrad, U. Köster, S. Kox, C. Lahonde-Hamdoun, J. Lamblin, A. Letourneau, D. Lhuillier, C. Li, M. Lindner, L. Manzanillas, T. Materna, O. Méplan, A. Minotti, C. Monon, F. Montanet, F. Nunio, F. Peltier, Y. Penichot, M. Pequignot, H. Pessard, Y. Piret, G. Prono, G. Quéméner, J.-S. Real, C. Roca, T. Salagnac, V. Sergeyeva, S. Schoppmann, L. Scola, J.-P. Scordilis, T. Soldner, A. Stutz, D. Tourres, C. Vescovi, S. Zsoldos
    April 24, 2018 hep-ex, physics.ins-det
    The STEREO experiment is a very short baseline reactor antineutrino experiment aiming at testing the hypothesis of light sterile neutrinos as an explanation of the deficit of the observed neutrino interaction rate with respect to the predicted rate, known as the Reactor Antineutrino Anomaly. The detector center is located 10 m away from the compact, highly $^{235}$U enriched core of the research nuclear reactor of the Institut Laue Langevin in Grenoble, France. This paper describes the STEREO site, the detector components and associated shielding designed to suppress the external sources of background which were characterized on site. It reports the performances in terms of detector response and energy reconstruction.
  • Demonstration of sensitivity increase in mercury free-spin-precession magnetometers due to laser-based readout for neutron electric dipole moment searches (1804.05838)

    G. Ban, G. Bison, K. Bodek, M. Daum, M. Fertl, B. Franke, Z. D. Grujić, W. Heil, M. Horras, M. Kasprzak, Y. Kermaidic, K. Kirch, H.-C. Koch, S. Komposch, A. Kozel, J. Krempel, B. Lauss, T. Lefort, A. Mtchedlishvili, G. Pignol, F.M. Piegsa, P. Prashanth, G. Quéméner, M. Rawlik, D. Rebreyend, D. Ries, S. Roccia, D. Rozpedzik, P. Schmidt-Wellenburg, N. Severijns, A. Weis, G. Wyszynski, J. Zejma, G. Zsigmond
    April 16, 2018 hep-ex, nucl-ex, physics.atom-ph, physics.ins-det
    We report on a laser based $^{199}$Hg co-magnetometer deployed in an experiment searching for a permanent electric dipole moment of the neutron. We demonstrate a more than five times increased signal to-noise-ratio in a direct comparison measurement with its $^{204}$Hg discharge bulb-based predecessor. An improved data model for the extraction of important system parameters such as the degrees of absorption and polarization is derived. Laser- and lamp-based data-sets can be consistently described by the improved model which permits to compare measurements using the two different light sources and to explain the increase in magnetometer performance. The laser-based magnetometer satisfies the magnetic field sensitivity requirements for the next generation nEDM experiments.
  • Electron shakeoff following the \b{eta}+ decay of 19Ne+ and 35Ar+ trapped ions (1802.01298)

    X. Fabian, X. Fléchard, B. Pons, E. Liénard, G. Ban, M. Breitenfeldt, C. Couratin, P. Delahaye, D. Durand, P. Finlay, B. Guillon, Y. Lemière, F. Mauger, A. Méry, O. Naviliat-Cuncic, T. Porobic, G. Quéméner, N. Severijns, J.-C. Thomas
    Feb. 5, 2018 nucl-ex
    The electron shakeoff of 19F and 35Cl atoms resulting from the \b{eta}+ decay of 19Ne+ and 35Ar+ ions has been investigated using a Paul trap coupled to a time of flight recoil-ion spectrometer. The charge-state distributions of the recoiling daughter nuclei were compared to theoretical calculations based on the sudden approximation and accounting for subsequent Auger processes. The excellent agreement obtained for 35Cl is not reproduced in 19F. The shortcoming is attributed to the inaccuracy of the independent particle model employed to calculate the primary shakeoff probabilities in systems with rather low atomic numbers. This calls for more elaborate calculations, including explicitly the electron-electron correlations.
  • A simple method of coil design (1709.04681)

    M. Rawlik, C. Crawford, A. Eggenberger, K. Kirch, J. Krempel, F. M. Piegsa, G. Quéméner
    Sept. 14, 2017 physics.ins-det
    In this article we present a method to design a coil producing an arbitrarily shaped magnetic field by restricting the path of the coil's wires to a regular grid. The solution is then found by a simple least squares minimum. We discuss practical applications, in particular in the active magnetic field stabilization system of the neutron electric dipole moment experiment at the Paul Scherrer Institute in Villigen, Switzerland. We also publish the software implementation of the method.
  • Ultracold neutron detection with 6Li-doped glass scintillators, NANOSC: a fast ultracold neutron detector for the nEDM experiment at the Paul Scherrer Institute (1606.07432)

    G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, P. Geltenbort, W.C. Griffith, V. Hélaine, R. Henneck, M. Kasprzak, Y. Kermaidic, K. Kirch, S. Komposch, P.A. Koss, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, M. Musgrave, O. Naviliat-Cuncic, F. M. Piegsa, E. Pierre, G. Pignol, G. Quéméner, M. Rawlik, D. Ries, D. Rebreyend, S. Roccia, G. Rogel, P. Schmidt-Wellenburg, N. Severijns, E. Wursten, J. Zejma, G. Zsigmond
    June 23, 2016 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    This paper summarizes the results from measurements aiming to characterize ultracold neutron detection with 6Li-doped glass scintillators. Single GS10 or GS20 scintillators, with a thickness of 100-200 micrometer, fulfill the ultracold neutron detection requirements with an acceptable neutron-gamma discrimination. This discrimination is clearly improved with a stack of two scintillators: a 6Li-depleted glass bonded to a 6Li-enriched glass. The optical contact bonding is used between the scintillators in order to obtain a perfect optical contact. The scintillator's detection efficiency is similar to that of a 3He Strelkov gas detector. Coupled to a digital data acquisition system, counting rates up to a few 10^5 counts/s can be handled. A detector based on such a scintillator stack arrangement was built and has been used in the neutron electric dipole moment experiment at the Paul Scherrer Institute since 2010. Its response for the regular runs of the neutron electric dipole moment experiment is presented.
  • Ultracold Dipolar Molecules Composed of Strongly Magnetic Atoms (1504.04578)

    A. Frisch, M. Mark, K. Aikawa, S. Baier, R. Grimm, A. Petrov, S. Kotochigova, G. Quéméner, M. Lepers, O. Dulieu, F. Ferlaino
    Nov. 23, 2015 physics.atom-ph, cond-mat.quant-gas
    ... ... ... ... ... ...
    In a combined experimental and theoretical effort, we demonstrate a novel type of dipolar system made of ultracold bosonic dipolar molecules with large magnetic dipole moments. Our dipolar molecules are formed in weakly bound Feshbach molecular states from a sample of strongly magnetic bosonic erbium atoms. We show that the ultracold magnetic molecules can carry very large dipole moments and we demonstrate how to create and characterize them, and how to change their orientation. Finally, we confirm that the relaxation rates of molecules in a quasi-two dimensional geometry can be reduced by using the anisotropy of the dipole-dipole interaction and that this reduction follows a universal dipolar behavior.
  • A Revised Experimental Upper Limit on the Electric Dipole Moment of the Neutron (1509.04411)

    J.M. Pendlebury, S. Afach, N.J. Ayres, C.A. Baker, G. Ban, G. Bison, K. Bodek, M. Burghoff, P. Geltenbort, K. Green, W.C. Griffith, M. van der Grinten, Z.D. Grujic, P.G. Harris, V. Helaine, P. Iaydjiev, S.N. Ivanov, M. Kasprzak, Y. Kermaidic, K. Kirch, H.-C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, D.J.R. May, M. Musgrave, O. Naviliat-Cuncic, F.M. Piegsa, G. Pignol, P.N. Prashanth, G. Quemener, M. Rawlik, D. Rebreyend, J.D. Richardson, D. Ries, S. Roccia, D. Rozpedzik, A. Schnabel, P. Schmidt-Wellenburg, N. Severijns, D. Shiers, J.A. Thorne, A. Weis, O.J. Winston, E. Wursten, J. Zejma, G. Zsigmond
    Oct. 13, 2015 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We present for the first time a detailed and comprehensive analysis of the experimental results that set the current world sensitivity limit on the magnitude of the electric dipole moment (EDM) of the neutron. We have extended and enhanced our earlier analysis to include recent developments in the understanding of the effects of gravity in depolarizing ultracold neutrons (UCN); an improved calculation of the spectrum of the neutrons; and conservative estimates of other possible systematic errors, which are also shown to be consistent with more recent measurements undertaken with the apparatus. We obtain a net result of $d_\mathrm{n} = -0.21 \pm 1.82 \times10^{-26}$ $e$cm, which may be interpreted as a slightly revised upper limit on the magnitude of the EDM of $3.0 \times10^{-26}$ $e$cm (90% CL) or $ 3.6 \times10^{-26}$ $e$cm (95% CL). This paper is dedicated by the remaining authors to the memory of Prof. J. Michael Pendlebury.
  • A device for simultaneous spin analysis of ultracold neutrons (1502.06876)

    S. Afach, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, Z.D. Grujić, L. Hayen, V. Hélaine, R. Henneck, M. Kasprzak, Y. Kermaidic, K. Kirch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, F.M. Piegsa, G. Pignol, P.N. Prashanth, G. Quéméner, M. Rawlik, D. Ries, D. Rebreyend, S. Roccia, D. Rozpedzik, P. Schmidt-Wellenburg, N. Severijns, A. Weis, E. Wursten, G. Wyszynski, J. Zejma, G. Zsigmond
    Oct. 12, 2015 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    We report on the design and first tests of a device allowing for measurement of ultracold neutrons polarisation by means of the simultaneous analysis of the two spin components. The device was developed in the framework of the neutron electric dipole moment experiment at the Paul Scherrer Institute. Individual parts and the entire newly built system have been characterised with ultracold neutrons. The gain in statistical sensitivity obtained with the simultaneous spin analyser is $(18.2\pm6.1)\%$ relative to the former sequential analyser under nominal running conditions.
  • Observation of gravitationally induced vertical striation of polarized ultracold neutrons by spin-echo spectroscopy (1506.00446)

    S. Afach, N.J. Ayres, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, W.C. Griffith, Z.D. Grujić, P.G. Harris, W. Heil, V. Hélaine, M. Kasprzak, Y. Kermaidic, K. Kirch, P. Knowles, H.-C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, M. Musgrave, O. Naviliat-Cuncic, J.M. Pendlebury, F.M. Piegsa, G. Pignol, C. Plonka-Spehr, P.N. Prashanth, G. Quéméner, M. Rawlik, D. Rebreyend, D. Ries, S. Roccia, D. Rozpedzik, P. Schmidt-Wellenburg, N. Severijns, J.A. Thorne, A. Weis, E. Wursten, G. Wyszynski, J. Zejma, J. Zenner, G. Zsigmond
    Sept. 8, 2015 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    We describe a spin-echo method for ultracold neutrons (UCNs) confined in a precession chamber and exposed to a $|B_0|=1~\text{\mu T}$ magnetic field. We have demonstrated that the analysis of UCN spin-echo resonance signals in combination with knowledge of the ambient magnetic field provides an excellent method by which to reconstruct the energy spectrum of a confined ensemble of neutrons. The method takes advantage of the relative dephasing of spins arising from a gravitationally induced striation of stored UCN of different energies, and also permits an improved determination of the vertical magnetic-field gradient with an exceptional accuracy of $1.1~\text{pT/cm}$. This novel combination of a well-known nuclear resonance method and gravitationally induced vertical striation is unique in the realm of nuclear and particle physics and should prove to be invaluable for the assessment of systematic effects in precision experiments such as searches for an electric dipole moment of the neutron or the measurement of the neutron lifetime.
  • Gravitational Depolarization of Ultracold Neutrons: Comparison with Data (1506.06563)

    S. Afach, N.J. Ayres, C.A. Baker, G. Ban, G. Bison, K. Bodek, M. Fertl, B. Franke, P. Geltenbort, K. Green, W.C. Griffith, M. van der Grinten, Z.D. Grujic, P.G. Harris, W. Heil, V. Helaine, P. Iaydjiev, S.N. Ivanov, M. Kasprzak, Y. Kermaidic, K. Kirch, H.-C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, M. Musgrave, O. Naviliat-Cunic, J.M. Pendlebury, F.M. Piegsa, G. Pignol, C. Plonka-Spehr, P.N. Prashanth, G. Quemener, M. Rawlik, D. Rebreyend, D. Ries, S. Roccia, D. Rozpedzik, P. Schmidt-Wellenburg, N. Severijns, D. Shiers, J.A. Thorne, A. Weis, E. Wursten, J. Zejma, J. Zenner, G. Zsigmond
    Aug. 26, 2015 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    We compare the expected effects of so-called gravitationally enhanced depolarization of ultracold neutrons to measurements carried out in a spin-precession chamber exposed to a variety of vertical magnetic-field gradients. In particular, we have investigated the dependence upon these field gradients of spin depolarization rates and also of shifts in the measured neutron Larmor precession frequency. We find excellent qualitative agreement, with gravitationally enhanced depolarization accounting for several previously unexplained features in the data.
  • Measurement of a false electric dipole moment signal from $^{199}$Hg atoms exposed to an inhomogeneous magnetic field (1503.08651)

    S. Afach, C. A. Baker, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, K. Green, M. G. D. van der Grinten, Z. Grujic, P. G. Harris, W. Heil, V. Hélaine, R. Henneck, M. Horras, P. Iaydjiev, S. N. Ivanov, M. Kasprzak, Y. Kermaïdic, K. Kirch, P. Knowles, H.-C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, J. M. Pendlebury, F. M. Piegsa, G. Pignol, P. N. Prashant, G. Quéméner, D. Rebreyend, D. Ries, S. Roccia, P. Schmidt-Wellenburg, N. Severijns, A. Weis, E. Wursten, G. Wyszynski, J. Zejma, J. Zenner, G. Zsigmond
    Aug. 3, 2015 nucl-ex, physics.atom-ph
    ... ... ... ... ... ...
    We report on the measurement of a Larmor frequency shift proportional to the electric-field strength for $^{199}{\rm Hg}$ atoms contained in a volume permeated with aligned magnetic and electric fields. This shift arises from the interplay between the inevitable magnetic field gradients and the motional magnetic field. The proportionality to electric-field strength makes it apparently similar to an electric dipole moment (EDM) signal, although unlike an EDM this effect is P- and T-conserving. We have used a neutron magnetic resonance EDM spectrometer, featuring a mercury co-magnetometer and an array of external cesium magnetometers, to measure the shift as a function of the applied magnetic field gradient. Our results are in good agreement with theoretical expectations.
  • A highly stable atomic vector magnetometer based on free spin precession (1507.08523)

    S. Afach, G. Ban, G. Bison, K. Bodek, Z. Chowdhuri, Z. D. Grujic, L. Hayen, V. Helaine, M. Kasprzak, K. Kirch, P. Knowles, H.-C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa, P. N. Prashanth, G. Quemener, M. Rawlik, D. Ries, S. Roccia, D. Rozpedzik, P. Schmidt-Wellenburg, N. Severjins, A. Weis, E. Wursten, G. Wyszynski, J. Zejma, G. Zsigmond
    July 30, 2015 physics.atom-ph
    ... ... ... ... ... ...
    We present a magnetometer based on optically pumped Cs atoms that measures the magnitude and direction of a 1 $\mu$T magnetic field. Multiple circularly polarized laser beams were used to probe the free spin precession of the Cs atoms. The design was optimized for long-time stability and achieves a scalar resolution better than 300 fT for integration times ranging from 80 ms to 1000 s. The best scalar resolution of less than 80 fT was reached with integration times of 1.6 to 6 s. We were able to measure the magnetic field direction with a resolution better than 10 $\mu$rad for integration times from 10 s up to 2000 s.
  • Precision measurements with LPCTrap at GANIL (1507.05838)

    E. Lienard, G. Ban, C. Couratin, P. Delahaye, D. Durand, X. Fabian, B. Fabre, X. Flechard, P. Finlay, F. Mauger, A. Mery, O. Naviliat-Cuncic, B. Pons, T. Porobic, G. Quemener, N. Severijns, J. C. Thomas, Ph. Velten
    July 21, 2015 nucl-ex
    The experimental achievements and the results obtained so far with the LPCTrap device installed at GANIL are presented. The apparatus is dedicated to the study of the weak interaction at low energy by means of precise measurements of the BETA-NU angular correlation parameter in nuclear BETA decays. So far, the data collected with three isotopes have enabled to determine, for the first time, the charge state distributions of the recoiling ions, induced by shakeoff process. The analysis is presently refined to deduce the correlation parameters, with the potential of improving both the constraint deduced at low energy on exotic tensor currents (6He1+) and the precision on the V u d element of the quark-mixing matrix (35Ar1+ and 19Ne1+) deduced from the mirror transitions dataset.
  • Constraining interactions mediated by axion-like particles with ultracold neutrons (1412.3679)

    S. Afach, G. Ban, G. Bison, K. Bodek, M. Burghoff, M. Daum, M. Fertl, B. Franke, Z. D. Grujić, V. Hélaine, M. Kasprzak, Y. Kermaïdic, K. Kirch, P. Knowles, H.-C. Koch, S. Komposch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, F. M. Piegsa, G. Pignol, P. N. Prashanth, G. Quéméner, D. Rebreyend, D. Ries, S. Roccia, P. Schmidt-Wellenburg, A. Schnabel, N. Severijns, J. Voigt, A. Weis, G. Wyszynski J. Zejma, J. Zenner, G. Zsigmond
    Dec. 11, 2014 hep-ph, hep-ex
    ... ... ... ... ... ...
    We report a new limit on a possible short range spin-dependent interaction from the precise measurement of the ratio of Larmor precession frequencies of stored ultracold neutrons and $^{199}$Hg atoms confined in the same volume. The measurement was performed in a $\sim$1$\mu$ T vertical magnetic holding field with the apparatus searching for a permanent electric dipole moment of the neutron at the Paul Scherrer Institute. A possible coupling between freely precessing polarized neutron spins and unpolarized nucleons of the wall material can be investigated by searching for a tiny change of the precession frequencies of neutron and mercury spins. Such a frequency change can be interpreted as a consequence of a short range spin-dependent interaction that could possibly be mediated by axions or axion-like particles. The interaction strength is proportional to the CP violating product of scalar and pseudoscalar coupling constants $g_Sg_P$. Our result confirms limits from complementary experiments with spin-polarized nuclei in a model-independent way. Limits from other neutron experiments are improved by up to two orders of magnitude in the interaction range of $10^{-6}<\lambda<10^{-4}$ m.
  • A measurement of the neutron to 199Hg magnetic moment ratio (1410.8259)

    S. Afach, C.A. Baker, G. Ban, G. Bison, K. Bodek, M. Burghoff, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, P. Geltenbort, K. Green, M.G.D. van der Grinten, Z. Grujic, P.G. Harris, W. Heil, V. Hélaine, R. Henneck, M. Horras, P. Iaydjiev, S.N. Ivanov, M. Kasprzak, Y. Kermaïdic, K. Kirch, A. Knecht, H.-C. Koch, J. Krempel, M. Kuźniak, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, J.M. Pendlebury, M. Perkowski, E. Pierre, F.M. Piegsa, G. Pignol, P.N. Prashanth, G. Quéméner, D. Rebreyend, D. Ries, S. Roccia, P. Schmidt-Wellenburg, A. Schnabel, N. Severijns, D. Shiers, K.F. Smith, J. Voigt, A. Weis, G. Wyszynski, J. Zejma, J. Zenner, G. Zsigmond
    Oct. 31, 2014 nucl-ex, physics.atom-ph, physics.ins-det
    ... ... ... ... ... ...
    The neutron gyromagnetic ratio has been measured relative to that of the 199Hg atom with an uncertainty of 0.8 ppm. We employed an apparatus where ultracold neutrons and mercury atoms are stored in the same volume and report the result $\gamma_{\rm n}/\gamma_{\rm Hg} = 3.8424574(30)$.
  • Dynamic stabilization of the magnetic field surrounding the neutron electric dipole moment spectrometer at the Paul Scherrer Institute (1408.6752)

    S. Afach, G. Bison, K. Bodek, F. Burri, Z. Chowdhuri, M. Daum, M. Fertl, B. Franke, Z. Grujic, V. Helaine, R. Henneck, M. Kasprzak, K. Kirch, H.-C. Koch, A. Kozela, J. Krempel, B. Lauss, T. Lefort, Y. Lemiere, M. Meier, O. Naviliat-Cuncic, F.M. Piegsa, G. Pignol, C. Plonka-Spehr, P.N. Prashanth, G. Quemener, D. Rebreyend, S. Roccia, P. Schmidt-Wellenburg, A. Schnabel, N. Severijns, J. Voigt, A. Weis, G. Wyszynski, J. Zejma, J. Zenner, G. Zsigmond
    Aug. 28, 2014 nucl-ex, physics.atom-ph, physics.ins-det
    ... ... ... ... ... ...
    The Surrounding Field Compensation (SFC) system described in this work is installed around the four-layer Mu-metal magnetic shield of the neutron electric dipole moment spectrometer located at the Paul Scherrer Institute. The SFC system reduces the DC component of the external magnetic field by a factor of about 20. Within a control volume of approximately 2.5m x 2.5m x 3m disturbances of the magnetic field are attenuated by factors of 5 to 50 at a bandwidth from $10^{-3}$ Hz up to 0.5 Hz, which corresponds to integration times longer than several hundreds of seconds and represent the important timescale for the nEDM measurement. These shielding factors apply to random environmental noise from arbitrary sources. This is achieved via a proportional-integral feedback stabilization system that includes a regularized pseudoinverse matrix of proportionality factors which correlates magnetic field changes at all sensor positions to current changes in the SFC coils.
  • Electron shakeoff following the ?+ decay of trapped 35Ar+ ions (1310.3103)

    C. Couratin, B. Fabre, B. Pons, X. Fléchard, M. Breitenfeldt, P. Delahaye, O. Naviliat-Cuncic (LPCC, NSCL), T. Porobic, G. Quéméner, D. Rodriguez, N. Severijns, J.C. Thomas, S. Van Gorp
    Oct. 28, 2013 nucl-ex, physics.atom-ph
    ... ... ... ... ... ...
    The electron shakeoff of $^{35}$Cl atoms resulting from the $\beta$$^+$ decay of $^{35}$Ar$^+$ ions has been investigated using a Paul trap coupled to a recoil-ion spectrometer. The charge-state distribution of the recoiling daughter nuclei is compared to theoretical calculations accounting for shakeoff and Auger processes. The calculations are in excellent agreement with the experimental results and enable to identify the ionization reaction routes leading to the formation of all charge states.
  • Virtual Compton Scattering and the Generalized Polarizabilities of the Proton at Q^2=0.92 and 1.76 GeV^2 (1205.3387)

    H. Fonvieille, G. Laveissiere, N. Degrande, S. Jaminion, C. Jutier, L. Todor, R. Di Salvo, L. Van Hoorebeke, L. C. Alexa, B. D. Anderson, K. A. Aniol, K. Arundell, G. Audit, L. Auerbach, F. T. Baker, M. Baylac, J. Berthot, P. Y. Bertin, W. Bertozzi, L. Bimbot, W. U. Boeglin, E. J. Brash, V. Breton, H. Breuer, E. Burtin, J. R. Calarco, L. S. Cardman, C. Cavata, C.-C. Chang, J.-P. Chen, E. Chudakov, E. Cisbani, D. S. Dale, C. W. deJager, R. De Leo, A. Deur, N. d'Hose, G. E. Dodge, J. J. Domingo, L. Elouadrhiri, M. B. Epstein, L. A. Ewell, J. M. Finn, K. G. Fissum, G. Fournier, B. Frois, S. Frullani, C. Furget, H. Gao, J. Gao, F. Garibaldi, A. Gasparian, S. Gilad, R. Gilman, A. Glamazdin, C. Glashausser, J. Gomez, V. Gorbenko, P. Grenier, P. A. M. Guichon, J. O. Hansen, R. Holmes, M. Holtrop, C. Howell, G. M. Huber, C. E. Hyde, S. Incerti, M. Iodice, J. Jardillier, M. K. Jones, W. Kahl, S. Kato, A. T. Katramatou, J. J. Kelly, S. Kerhoas, A. Ketikyan, M. Khayat, K. Kino, S. Kox, L. H. Kramer, K. S. Kumar, G. Kumbartzki, M. Kuss, A. Leone, J. J. LeRose, M. Liang, R. A. Lindgren, N. Liyanage, G. J. Lolos, R. W. Lourie, R. Madey, K. Maeda, S. Malov, D. M. Manley, C. Marchand, D. Marchand, D. J. Margaziotis, P. Markowitz, J. Marroncle, J. Martino, K. McCormick, J. McIntyre, S. Mehrabyan, F. Merchez, Z. E. Meziani, R. Michaels, G. W. Miller, J. Y. Mougey, S. K. Nanda, D. Neyret, E. A. J. M. Offermann, Z. Papandreou, B. Pasquini, C. F. Perdrisat, R. Perrino, G. G. Petratos, S. Platchkov, R. Pomatsalyuk, D. L. Prout, V. A. Punjabi, T. Pussieux, G. Quemener, R. D. Ransome, O. Ravel, J. S. Real, F. Renard, Y. Roblin, D. Rowntree, G. Rutledge, P. M. Rutt, A. Saha, T. Saito, A. J. Sarty, A. Serdarevic, T. Smith, G. Smirnov, K. Soldi, P. Sorokin, P. A. Souder, R. Suleiman, J. A. Templon, T. Terasawa, R. Tieulent, E. Tomasi-Gustaffson, H. Tsubota, H. Ueno, P. E. Ulmer, G. M. Urciuoli, M. Vanderhaeghen, R. L. J. Van der Meer, R. Van De Vyver, P. Vernin, B. Vlahovic, H. Voskanyan, E. Voutier, J. W. Watson, L. B. Weinstein, K. Wijesooriya, R. Wilson, B. B. Wojtsekhowski, D. G. Zainea, W.-M. Zhang, J. Zhao, Z.-L. Zhou
    June 28, 2012 hep-ex, nucl-ex
    ... ... ... ... ... ...
    Virtual Compton Scattering (VCS) on the proton has been studied at Jefferson Lab using the exclusive photon electroproduction reaction (e p --> e p gamma). This paper gives a detailed account of the analysis which has led to the determination of the structure functions P_LL-P_TT/epsilon and P_LT, and the electric and magnetic generalized polarizabilities (GPs) alpha_E(Q^2) and beta_M(Q^2) at values of the four-momentum transfer squared Q^2= 0.92 and 1.76 GeV^2. These data, together with the results of VCS experiments at lower momenta, help building a coherent picture of the electric and magnetic GPs of the proton over the full measured Q^2-range, and point to their non-trivial behavior.
  • An Improved Search for the Neutron Electric Dipole Moment (1110.1505)

    M. Burghoff, A. Schnabel, G. Ban, T. Lefort, Y. Lemiere, O. Naviliat-Cuncic, E. Pierre, G. Quemener, J. Zejma, M. Kasprzak, P. Knowles, A. Weis, G. Pignol, D. Rebreyend, S. Afach, G. Bison, J. Becker, N. Severijns, S. Roccia, C. Plonka-Spehr, J. Zennerz, W. Heil, H. C. Koch, A. Kraft, T. Lauer, Yu. Sobolev, Z. Chowdhuri, J. Krempel, B. Lauss, A. Mtchedlishvili, P. Schmidt-Wellenburg, G. Zsigmond, M. Fertl, B. Franke, M. Horras, K. Kirch, F. Piegsa
    Oct. 7, 2011 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    A permanent electric dipole moment of fundamental spin-1/2 particles violates both parity (P) and time re- versal (T) symmetry, and hence, also charge-parity (CP) symmetry since there is no sign of CPT-violation. The search for a neutron electric dipole moment (nEDM) probes CP violation within and beyond the Stan- dard Model. The experiment, set up at the Paul Scherrer Institute (PSI), an improved, upgraded version of the apparatus which provided the current best experimental limit, dn < 2.9E-26 ecm (90% C.L.), by the RAL/Sussex/ILL collaboration: Baker et al., Phys. Rev. Lett. 97, 131801 (2006). In the next two years we aim to improve the sensitivity of the apparatus to sigma(dn) = 2.6E-27 ecm corresponding to an upper limit of dn < 5E-27 ecm (95% C.L.), in case for a null result. In parallel the collaboration works on the design of a new apparatus to further increase the sensitivity to sigma(dn) = 2.6E-28 ecm.
  • Cold collision shift cancelation and inelastic scattering in a Yb optical lattice clock (1108.1379)

    A. D. Ludlow, N. D. Lemke, J. A. Sherman, C. W. Oates, G. Quemener, J. von Stecher, A. M. Rey
    Aug. 10, 2011 physics.atom-ph, physics.optics
    Recently, p-wave cold collisions were shown to dominate the density-dependent shift of the clock transition frequency in a 171Yb optical lattice clock. Here we demonstrate that by operating such a system at the proper excitation fraction, the cold collision shift is canceled below the 5x10^{-18} fractional frequency level. We report inelastic two-body loss rates for 3P0-3P0 and 1S0-3P0 scattering. We also measure interaction shifts in an unpolarized atomic sample. Collision measurements for this spin-1/2 171Yb system are relevant for high performance optical clocks as well as strongly-interacting systems for quantum information and quantum simulation applications.
  • The G0 Experiment: Apparatus for Parity-Violating Electron Scattering Measurements at Forward and Backward Angles (1103.0761)

    G0 Collaboration: D. Androic, D.S. Armstrong, J. Arvieux, R. Asaturyan, T. D. Averett, S. L. Bailey, G. Batigne, D. H. Beck, E. J. Beise, J. Benesch, F. Benmokhtar, L. Bimbot, J. Birchall, A. Biselli, P. Bosted, H. Breuer, P. Brindza, C. L. Capuano, R. D. Carlini, R. Carr, N. Chant, Y.-C. Chao, R. Clark, A. Coppens, S. D. Covrig, A. Cowley, D. Dale, C. A. Davis, C. Ellis, W. R. Falk, H. Fenker, J. M. Finn, T. Forest, G. Franklin, R. Frascaria, C. Furget, D. Gaskell, M. T. W. Gericke, J. Grames, K. A. Griffioen, K. Grimm, G. Guillard, B. Guillon, H. Guler, K. Gustafsson, L. Hannelius, J. Hansknecht, R. D. Hasty, A. M. Hawthorne Allen, T. Horn, T. M. Ito, K. Johnston, M. Jones, P. Kammel, R. Kazimi, P. M. King, A. Kolarkar, E. Korkmaz, W. Korsch, S. Kox, J. Kuhn, J. Lachniet, R. Laszewski, L. Lee, J. Lenoble, E. Liatard, J. Liu, A. Lung, G. A. MacLachlan, J. Mammei, D. Marchand, J. W. Martin, D. J. Mack, K. W. McFarlane, D. W. McKee, R. D. McKeown, F. Merchez, M. Mihovilovic, A. Micherdzinska, H. Mkrtchyan, B. Moffit, M. Morlet, M. Muether, J. Musson, K. Nakahara, R. Neveling, S. Niccolai, D. Nilsson, S. Ong, S. A. Page, V. Papavassiliou, S. F. Pate, S. K. Phillips, P. Pillot, M. L. Pitt, M. Poelker, T. A. Porcelli, G. Quemener, B. P. Quinn, W. D. Ramsay, A. W. Rauf, J.-S. Real, T. Ries, J. Roche P. Roos, G. A. Rutledge, J. Schaub, J. Secrest, T. Seva, N. Simicevic, G. R. Smith, D. T. Spayde, S. Stepanyan, M. Stutzman, R. Suleiman, V. Tadevosyan, R. Tieulent, J. van de Wiele, W. T. H. van Oers, M. Versteegen, E. Voutier, W. F. Vulcan, S. P. Wells, G. Warren, S. E. Williamson, R. J. Woo, S. A. Wood, C. Yan, J. Yun, V. Zeps
    March 3, 2011 nucl-ex, physics.ins-det
    ... ... ... ... ... ...
    In the G0 experiment, performed at Jefferson Lab, the parity-violating elastic scattering of electrons from protons and quasi-elastic scattering from deuterons is measured in order to determine the neutral weak currents of the nucleon. Asymmetries as small as 1 part per million in the scattering of a polarized electron beam are determined using a dedicated apparatus. It consists of specialized beam-monitoring and control systems, a cryogenic hydrogen (or deuterium) target, and a superconducting, toroidal magnetic spectrometer equipped with plastic scintillation and aerogel Cerenkov detectors, as well as fast readout electronics for the measurement of individual events. The overall design and performance of this experimental system is discussed.
  • Controlling the quantum stereodynamics of ultracold bimolecular reactions (1010.3731)

    M. H. G. de Miranda, A. Chotia, B. Neyenhuis, D. Wang, G. Quemener, S. Ospelkaus, J. L. Bohn, J. Ye, D. S. Jin
    Oct. 18, 2010 quant-ph, physics.atom-ph, cond-mat.quant-gas
    ... ... ... ... ... ...
    Chemical reaction rates often depend strongly on stereodynamics, namely the orientation and movement of molecules in three-dimensional space. An ultracold molecular gas, with a temperature below 1 uK, provides a highly unusual regime for chemistry, where polar molecules can easily be oriented using an external electric field and where, moreover, the motion of two colliding molecules is strictly quantized. Recently, atom-exchange reactions were observed in a trapped ultracold gas of KRb molecules. In an external electric field, these exothermic and barrierless bimolecular reactions, KRb+KRb -> K2+Rb2, occur at a rate that rises steeply with increasing dipole moment. Here we show that the quantum stereodynamics of the ultracold collisions can be exploited to suppress the bimolecular chemical reaction rate by nearly two orders of magnitude. We use an optical lattice trap to confine the fermionic polar molecules in a quasi-two-dimensional, pancake-like geometry, with the dipoles oriented along the tight confinement direction. With the combination of sufficiently tight confinement and Fermi statistics of the molecules, two polar molecules can approach each other only in a "side-by-side" collision, where the chemical reaction rate is suppressed by the repulsive dipole-dipole interaction. We show that the suppression of the bimolecular reaction rate requires quantum-state control of both the internal and external degrees of freedom of the molecules. The suppression of chemical reactions for polar molecules in a quasi-two-dimensional trap opens the way for investigation of a dipolar molecular quantum gas. Because of the strong, long-range character of the dipole-dipole interactions, such a gas brings fundamentally new abilities to quantum-gas-based studies of strongly correlated many-body physics, where quantum phase transitions and new states of matter can emerge.
  • Testing isotropy of the universe using the Ramsey resonance technique on ultracold neutron spins (1009.6060)

    I. Altarev, G. Ban, G. Bison, K. Bodek, M. Daum, M. Fertl, P. Fierlinger, B. Franke, E. Gutsmiedl, W. Heil, R. Henneck, M. Horras, N. Khomutov, K. Kirch, S. Kistryn, A. Kraft, A. Knecht, P. Knowles, A. Kozela, T. Lauer, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, A. Pazgalev, G. Petzoldt, F. M. Piegsa, E. Pierre, G. Pignol, G. Quéméner, M. Rebetez, D. Rebreyend, S. Roccia, P. Schmidt-Wellenburg, N. Severijns, Yu. Sobolev, A. Weis, J. Zejma, J. Zenner, , G. Zsigmond
    Sept. 30, 2010 hep-ex, nucl-ex, physics.atom-ph
    ... ... ... ... ... ...
    Physics at the Planck scale could be revealed by looking for tiny violations of fundamental symmetries in low energy experiments. In 2008, a sensitive test of the isotropy of the Universe using has been performed with stored ultracold neutrons (UCN), this is the first clock-comparison experiment performed with free neutrons. During several days we monitored the Larmor frequency of neutron spins in a weak magnetic field using the Ramsey resonance technique. An non-zero cosmic axial field, violating rotational symmetry, would induce a daily variation of the precession frequency. Our null result constitutes one of the most stringent tests of Lorentz invariance to date.
  • New constraints on Lorentz invariance violation from the neutron electric dipole moment (1006.4967)

    I. Altarev, C. A. Baker, G. Ban, K. Bodek, M. Daum, M. Fertl, B. Franke, P. Fierlinger, P. Geltenbort, K. Green, M. G. D. van der Grinten, P. G. Harris, R. Henneck, M. Horras, P. Iaydjiev, S. N. Ivanov, N. Khomutov, K. Kirch, S. Kistryn, A. Knecht, A. Kozela, F. Kuchler, B. Lauss, T. Lefort, Y. Lemière, A. Mtchedlishvili, O. Naviliat-Cuncic, J. M. Pendlebury, G. Petzoldt, E. Pierre, F. M. Piegsa, G. Pignol, G. Quéméner, D. Rebreyend, S. Roccia, P. Schmidt-Wellenburg, N. Severijns, D. Shiers, K. F. Smith, Yu. Sobolev, J. Zejma, J. Zenner, G. Zsigmond
    June 25, 2010 nucl-ex
    ... ... ... ... ... ...
    We propose an original test of Lorentz invariance in the interaction between a particle spin and an electromagnetic field and report on a first measurement using ultracold neutrons. We used a high sensitivity neutron electric dipole moment (nEDM) spectrometer and searched for a direction dependence of a nEDM signal leading to a modulation of its magnitude at periods of 12 and 24 hours. We constrain such a modulation to $d_{12} < 15 \times 10^{-25} \ e\,{\rm cm}$ and $d_{24} < 10 \times 10^{-25} \ e\,{\rm cm}$ at 95~\% C.L. The result translates into a limit on the energy scale for this type of Lorentz violation effect at the level of ${\cal E}_{LV} > 10^{10}$~GeV.
  • Dipolar collisions of polar molecules in the quantum regime (1001.2809)

    K.-K. Ni, S. Ospelkaus, D. Wang, G. Quemener, B. Neyenhuis, M. H. G. de Miranda, J. L. Bohn, J. Ye, D. S. Jin
    Jan. 16, 2010 physics.atom-ph, physics.gen-ph, cond-mat.quant-gas
    ... ... ... ... ... ...
    Ultracold polar molecules offer the possibility of exploring quantum gases with interparticle interactions that are strong, long-range, and spatially anisotropic. This is in stark contrast to the dilute gases of ultracold atoms, which have isotropic and extremely short-range, or "contact", interactions. The large electric dipole moment of polar molecules can be tuned with an external electric field; this provides unique opportunities such as control of ultracold chemical reactions, quantum information processing, and the realization of novel quantum many-body systems. In spite of intense experimental efforts aimed at observing the influence of dipoles on ultracold molecules, only recently have sufficiently high densities been achieved. Here, we report the observation of dipolar collisions in an ultracold molecular gas prepared close to quantum degeneracy. For modest values of an applied electric field, we observe a dramatic increase in the loss rate of fermionic KRb molecules due to ultrcold chemical reactions. We find that the loss rate has a steep power-law dependence on the induced electric dipole moment, and we show that this dependence can be understood with a relatively simple model based on quantum threshold laws for scattering of fermionic polar molecules. We directly observe the spatial anisotropy of the dipolar interaction as manifested in measurements of the thermodynamics of the dipolar gas. These results demonstrate how the long-range dipolar interaction can be used for electric-field control of chemical reaction rates in an ultracold polar molecule gas. The large loss rates in an applied electric field suggest that creating a long-lived ensemble of ultracold polar molecules may require confinement in a two-dimensional trap geometry to suppress the influence of the attractive dipolar interactions.