The single-phase liquid argon time projection chamber (LArTPC) provides a
large amount of detailed information in the form of fine-grained drifted
ionization charge from particle traces. To fully utilize this information, the
deposited charge must be accurately extracted from the raw digitized waveforms
via a robust signal processing chain. Enabled by the ultra-low noise levels
associated with cryogenic electronics in the MicroBooNE detector, the precise
extraction of ionization charge from the induction wire planes in a
single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event
display images, and quantitatively demonstrated via waveform-level and
track-level metrics. Improved performance of induction plane calorimetry is
demonstrated through the agreement of extracted ionization charge measurements
across different wire planes for various event topologies. In addition to the
comprehensive waveform-level comparison of data and simulation, a calibration
of the cryogenic electronics response is presented and solutions to various
MicroBooNE-specific TPC issues are discussed. This work presents an important
improvement in LArTPC signal processing, the foundation of reconstruction and
therefore physics analyses in MicroBooNE.
-
We describe the concept and procedure of drifted-charge extraction developed
in the MicroBooNE experiment, a single-phase liquid argon time projection
chamber (LArTPC). This technique converts the raw digitized TPC waveform to the
number of ionization electrons passing through a wire plane at a given time. A
robust recovery of the number of ionization electrons from both induction and
collection anode wire planes will augment the 3D reconstruction, and is
particularly important for tomographic reconstruction algorithms. A number of
building blocks of the overall procedure are described. The performance of the
signal processing is quantitatively evaluated by comparing extracted charge
with the true charge through a detailed TPC detector simulation taking into
account position-dependent induced current inside a single wire region and
across multiple wires. Some areas for further improvement of the performance of
the charge extraction procedure are also discussed.
-
We discuss a technique for measuring a charged particle's momentum by means
of multiple Coulomb scattering (MCS) in the MicroBooNE liquid argon time
projection chamber (LArTPC). This method does not require the full particle
ionization track to be contained inside of the detector volume as other track
momentum reconstruction methods do (range-based momentum reconstruction and
calorimetric momentum reconstruction). We motivate use of this technique,
describe a tuning of the underlying phenomenological formula, quantify its
performance on fully contained beam-neutrino-induced muon tracks both in
simulation and in data, and quantify its performance on exiting muon tracks in
simulation. Using simulation, we have shown that the standard Highland formula
should be re-tuned specifically for scattering in liquid argon, which
significantly improves the bias and resolution of the momentum measurement.
With the tuned formula, we find agreement between data and simulation for
contained tracks, with a small bias in the momentum reconstruction and with
resolutions that vary as a function of track length, improving from about 10%
for the shortest (one meter long) tracks to 5% for longer (several meter)
tracks. For simulated exiting muons with at least one meter of track contained,
we find a similarly small bias, and a resolution which is less than 15% for
muons with momentum below 2 GeV/c. Above 2 GeV/c, results are given as a first
estimate of the MCS momentum measurement capabilities of MicroBooNE for high
momentum exiting tracks.
-
The MicroBooNE liquid argon time projection chamber (LArTPC) has been taking
data at Fermilab since 2015 collecting, in addition to neutrino beam,
cosmic-ray muons. Results are presented on the reconstruction of Michel
electrons produced by the decay at rest of cosmic-ray muons. Michel electrons
are abundantly produced in the TPC, and given their well known energy spectrum
can be used to study MicroBooNE's detector response to low-energy electrons
(electrons with energies up to ~50 MeV). We describe the fully-automated
algorithm developed to reconstruct Michel electrons, with which a sample of
~14,000 Michel electron candidates is obtained. Most of this article is
dedicated to studying the impact of radiative photons produced by Michel
electrons on the accuracy and resolution of their energy measurement. In this
energy range, ionization and bremsstrahlung photon production contribute
similarly to electron energy loss in argon, leading to a complex electron
topology in the TPC. By profiling the performance of the reconstruction
algorithm on simulation we show that the ability to identify and include energy
deposited by radiative photons leads to a significant improvement in the energy
measurement of low-energy electrons. The fractional energy resolution we
measure improves from over 30% to ~20% when we attempt to include radiative
photons in the reconstruction. These studies are relevant to a large number of
analyses which aim to study neutrinos by measuring electrons produced by
$\nu_e$ interactions over a broad energy range.
-
The development and operation of Liquid-Argon Time-Projection Chambers for
neutrino physics has created a need for new approaches to pattern recognition
in order to fully exploit the imaging capabilities offered by this technology.
Whereas the human brain can excel at identifying features in the recorded
events, it is a significant challenge to develop an automated, algorithmic
solution. The Pandora Software Development Kit provides functionality to aid
the design and implementation of pattern-recognition algorithms. It promotes
the use of a multi-algorithm approach to pattern recognition, in which
individual algorithms each address a specific task in a particular topology.
Many tens of algorithms then carefully build up a picture of the event and,
together, provide a robust automated pattern-recognition solution. This paper
describes details of the chain of over one hundred Pandora algorithms and tools
used to reconstruct cosmic-ray muon and neutrino events in the MicroBooNE
detector. Metrics that assess the current pattern-recognition performance are
presented for simulated MicroBooNE events, using a selection of final-state
event topologies.
-
The MicroBooNE detector is a liquid argon time projection chamber at Fermilab
designed to study short-baseline neutrino oscillations and neutrino-argon
interaction cross-section. Due to its location near the surface, a good
understanding of cosmic muons as a source of backgrounds is of fundamental
importance for the experiment. We present a method of using an external 0.5 m
(L) x 0.5 m (W) muon counter stack, installed above the main detector, to
determine the cosmic-ray reconstruction efficiency in MicroBooNE. Data are
acquired with this external muon counter stack placed in three different
positions, corresponding to cosmic rays intersecting different parts of the
detector. The data reconstruction efficiency of tracks in the detector is found
to be $\epsilon_{\mathrm{data}}=(97.1\pm0.1~(\mathrm{stat}) \pm
1.4~(\mathrm{sys}))\%$, in good agreement with the Monte Carlo reconstruction
efficiency $\epsilon_{\mathrm{MC}} = (97.4\pm0.1)\%$. This analysis represents
a small-scale demonstration of the method that can be used with future data
coming from a recently installed cosmic-ray tagger system, which will be able
to tag $\approx80\%$ of the cosmic rays passing through the MicroBooNE
detector.
-
The low-noise operation of readout electronics in a liquid argon time
projection chamber (LArTPC) is critical to properly extract the distribution of
ionization charge deposited on the wire planes of the TPC, especially for the
induction planes. This paper describes the characteristics and mitigation of
the observed noise in the MicroBooNE detector. The MicroBooNE's single-phase
LArTPC comprises two induction planes and one collection sense wire plane with
a total of 8256 wires. Current induced on each TPC wire is amplified and shaped
by custom low-power, low-noise ASICs immersed in the liquid argon. The
digitization of the signal waveform occurs outside the cryostat. Using data
from the first year of MicroBooNE operations, several excess noise sources in
the TPC were identified and mitigated. The residual equivalent noise charge
(ENC) after noise filtering varies with wire length and is found to be below
400 electrons for the longest wires (4.7 m). The response is consistent with
the cold electronics design expectations and is found to be stable with time
and uniform over the functioning channels. This noise level is significantly
lower than previous experiments utilizing warm front-end electronics.
-
We describe and report the status of a neutrino-triggered program in IceCube
that generates real-time alerts for gamma-ray follow-up observations by
atmospheric-Cherenkov telescopes (MAGIC and VERITAS). While IceCube is capable
of monitoring the whole sky continuously, high-energy gamma-ray telescopes have
restricted fields of view and in general are unlikely to be observing a
potential neutrino-flaring source at the time such neutrinos are recorded. The
use of neutrino-triggered alerts thus aims at increasing the availability of
simultaneous multi-messenger data during potential neutrino flaring activity,
which can increase the discovery potential and constrain the phenomenological
interpretation of the high-energy emission of selected source classes (e.g.
blazars). The requirements of a fast and stable online analysis of potential
neutrino signals and its operation are presented, along with first results of
the program operating between 14 March 2012 and 31 December 2015.
-
Neutrino oscillation models involving one extra mass eigenstate beyond the
standard three ($3+1$) are fit to global short baseline experimental data and
the recent IceCube $\nu_\mu+\bar\nu_\mu$ disappearance search result. We find a
best fit of $\Delta m^2_{41} = 1.75\; \text{eV}^2$ with $\Delta
\chi^2_{null-min}$ (dof) of 50.61 (4). We find that the combined IceCube and
short baseline data constrain $\theta_{34}$ to $< 80^\circ (< 6^\circ) $ at
90\% C.L. for $\Delta m^2_{41} \approx 2 (6)~\text{eV}^2$, which is improved
over present limits. Incorporating the IceCube information provides the first
constraints on all entries of the 3+1 mixing matrix.
-
Kilometer$^3$-scale neutrino detectors such as IceCube, ANTARES, and the
proposed Km3Net neutrino observatory in the Mediterranean have measured, and
will continue to characterize, the atmospheric neutrino spectrum above 1 TeV.
Such precise measurements enable us to probe new neutrino physics, in
particular, those that arise from Lorentz violation. In this paper, we first
relate the effective new physics hamiltonian terms with the Lorentz violating
literature. Second, we calculate the oscillation probability formulas for the
two-level $\nu_\mu-\nu_\tau$ sector. Finally, we comment on some of the
challenges and outlook for this analysis.
-
Neutrino oscillation models involving extra mass eigenstates beyond the
standard three (3+N) are fit to global short baseline experimental data. We
find that 3+1 has a best fit of Delta m^2_41 = 1.75 eV^2 with a Delta chi^2
[null-min] (dof) of 52.34 (3). The 3+2 fit has a Delta chi^2 [null-min] (dof)
of 56.99 (7). Bayesian credible intervals are shown for the first time for a
3+1 model. These are found to be in agreement with frequentist intervals. The
results of these new fits favor a higher Delta m^2 value than previous studies,
which may have an impact on future sterile neutrino searches such as the
Fermilab SBN program.
-
This conceptual design report describes the technical facility for the IsoDAR
electron-antineutrino source at KamLAND. The IsoDAR source will allow an
impressive program of neutrino oscillation and electroweak physics to be
performed at KamLAND. This report provides information on the physics case, the
conceptual design for the subsystems, alternative designs considered, specifics
of installation at KamLAND, and identified needs for future development. We
discuss the risks we have identified and our approach to mitigating those risks
with this design. A substantial portion of the conceptual design is based on
three years of experimental efforts and on industry experience. This report
also includes information on the conventional facilities.
-
This paper will discuss a new method of signal read-out from photon detectors
in ultra-large, underground liquid argon time projection chambers. In this
design, the signal from the light collection system is coupled via capacitive
plates to the TPC wire-planes. This signal is then read out using the same
cabling and electronics as the charge information. This greatly benefits light
collection: it eliminates the need for an independent readout, substantially
reducing cost; It reduces the number of cables in the vapor region of the TPC
that can produce impurities; And it cuts down on the number of feed-throughs in
the cryostat wall that can cause heat-leaks and potential points of failure. We
present experimental results that demonstrate the sensitivity of a LArTPC wire
plane to photon detector signals. We also simulate the effect of a 1 $\mu$s
shaping time and a 2 MHz sampling rate on these signals in the presence of
noise, and find that a single photoelectron timing resolution of $\sim$30 ns
can be achieved.