The MAGIC telescopes are two Imaging Atmospheric Cherenkov Telescopes (IACTs)
located on the Canary island of La Palma. The telescopes are designed to
measure Cherenkov light from air showers initiated by gamma rays in the energy
regime from around 50 GeV to more than 50 TeV. The two telescopes were built in
2004 and 2009, respectively, with different cameras, triggers and readout
systems. In the years 2011-2012 the MAGIC collaboration undertook a major
upgrade to make the stereoscopic system uniform, improving its overall
performance and easing its maintenance. In particular, the camera, the
receivers and the trigger of the first telescope were replaced and the readout
of the two telescopes was upgraded. This paper (Part I) describes the details
of the upgrade as well as the basic performance parameters of MAGIC such as raw
data treatment, dead time of the system, linearity in the electronic chain and
sources of noise. In Part II, we describe the physics performance of the
upgraded system.
MAGIC is a system of two Imaging Atmospheric Cherenkov Telescopes located in
the Canary island of La Palma, Spain. During summer 2011 and 2012 it underwent
a series of upgrades, involving the exchange of the MAGIC-I camera and its
trigger system, as well as the upgrade of the readout system of both
telescopes. We use observations of the Crab Nebula taken at low and medium
zenith angles to assess the key performance parameters of the MAGIC stereo
system. For low zenith angle observations, the standard trigger threshold of
the MAGIC telescopes is ~50GeV. The integral sensitivity for point-like sources
with Crab Nebula-like spectrum above 220GeV is (0.66+/-0.03)% of Crab Nebula
flux in 50 h of observations. The angular resolution, defined as the sigma of a
2-dimensional Gaussian distribution, at those energies is < 0.07 degree, while
the energy resolution is 16%. We also re-evaluate the effect of the systematic
uncertainty on the data taken with the MAGIC telescopes after the upgrade. We
estimate that the systematic uncertainties can be divided in the following
components: < 15% in energy scale, 11-18% in flux normalization and +/-0.15 for
the energy spectrum power-law slope.