-
The direct detection of dark matter particles requires ultra-low background
conditions at energies below a few tens of keV; cosmogenic activation produced
at sea level in detectors and other materials is one of the background sources
which has to be under control. In particular, tritium is specially relevant for
its decay properties (very low endpoint energy and long half-life) when induced
in the detector medium, and because it can be generated in any material as an
spallation product. Quantification of cosmogenic production of tritium is not
easy. A method for the calculation of production rates at sea level has been
developed and applied to some of the materials typically used as targets in
dark matter detectors (germanium, sodium iodide, argon and neon); it is based
on a selection of excitation functions over the entire energy range of cosmic
nucleons. Results have been compared with available data in the literature,
either from other calculations or from measurements. The obtained tritium
production rates, ranging from a few tens to a few hundreds of nuclei per kg
and per day at sea level, point to a significant contribution to the background
in dark matter experiments, requiring the application of specific protocols for
target material purification, material storing underground and limiting the
time the detector is on surface during the building process in order to
minimize the exposure to the most dangerous cosmic rays component.
-
The measurement of the direction of WIMP-induced nuclear recoils is a
compelling but technologically challenging strategy to provide an unambiguous
signature of the detection of Galactic dark matter. Most directional detectors
aim to reconstruct the dark-matter-induced nuclear recoil tracks, either in gas
or solid targets. The main challenge with directional detection is the need for
high spatial resolution over large volumes, which puts strong requirements on
the readout technologies. In this paper we review the various detector readout
technologies used by directional detectors. In particular, we summarize the
challenges, advantages and drawbacks of each approach, and discuss future
prospects for these technologies.
-
In the search for the neutrinoless double beta decay of $^{136}$Xe, a high
pressure xenon time projection chamber (HPXe-TPC) has two advantages over
liquid xenon TPCs: a better energy resolution and the access to topological
features, which may provide extra discrimination from background events. The
PandaX-III experiment has recently proposed a 200 kg HPXe-TPC based on
Micromegas readout planes, to be located at the Jinping Underground Laboratory
in China. Its detection concept is based on two results obtained within the
T-REX project: Micromegas readouts can be built with extremely low levels of
radioactivity; and the operation in xenon-trimethylamine at 10 bar in realistic
experimental conditions has proven an energy resolution of 3% FWHM at the
region of interest. In this work, two discrimination methods are applied to
simulated signal and background data in a generic 200 kg HPXe-TPC, based on two
well-known algorithms of graph theory: the identification of connections and
the search for the longest path. Rejection factors greater than 100 are
obtained for small pixel sizes and a signal efficiency of 40%. Moreover, a new
observable (the blob charge density) rejects better surface contaminations,
which makes the use of a trigger signal ($T_0$) not imperative in this
experiment.
-
The most compelling candidates for Dark Matter to day are WIMPs and axions.
The applicability of gasesous Time Projection Chambers (TPCs) with Micromesh
Gas Structures (Micromegas) to the search of these particles is explored within
this work. Both particles would produce an extremely low rate at very low
energies in particle detectors. Micromegas detectors can provide both low
background rates and low en- ergy threshold, due to the high granularity,
radiopurity and uniformity of the readout. Small (few cm wide) Micromegas
detectors are used to image the axion-induced x-ray signal expected in the CERN
Axion Solar Telescope (CAST) experiment. We show the background levels obtained
in CAST and the prospects to further reduce them to the values required by the
Internation Axion Observatory (IAXO). We also present TREX-DM, a scaled-up
version of the Micromegas used in axion research, but this time dedicated to
the low-mass WIMP detection. TREX-DM is a high-pressure Micromegas-based TPC
designed to host a few hundreds of grams of light nuclei (argon or neon) with
energy thresholds potentially at the level of 100 eV. The detector is described
in detail, as well as the results of the commissioning and characterization
phase on surface. Besides, the back- ground model of TREX-DM is presented,
along with the anticipated sensitivity of this search, which could go beyond
current experimental limits.
-
As part of the T-REX project, a number of R&D and prototyping activities have
been carried out during the last years to explore the applicability of
Micromegas-read gaseous TPCs in rare event searches like double beta decay
(DBD), axion research and low-mass WIMP searches. While in the companion paper
we focus on DBD, in this paper we focus on the results regarding the search for
dark matter candidates, both axions and WIMPs. Small ultra-low background
Micromegas detectors are used to image the x-ray signal expected in axion
helioscopes like CAST at CERN. Background levels as low as $0.8\times 10^{-6}$
c keV$^{-1}$cm$^{-2}$s$^{-1}$ have already been achieved in CAST while values
down to $\sim10^{-7}$ c keV$^{-1}$cm$^{-2}$s$^{-1}$ have been obtained in a
test bench placed underground in the Laboratorio Subterr\'aneo de Canfranc.
Prospects to consolidate and further reduce these values down to $\sim10^{-8}$
c keV$^{-1}$cm$^{-2}$s$^{-1}$will be described. Such detectors, placed at the
focal point of x-ray telescopes in the future IAXO experiment, would allow for
10$^5$ better signal-to-noise ratio than CAST, and search for solar axions with
$g_{a\gamma}$ down to few 10$^{12}$ GeV$^{-1}$, well into unexplored axion
parameter space. In addition, a scaled-up version of these TPCs, properly
shielded and placed underground, can be competitive in the search for low-mass
WIMPs. The TREX-DM prototype, with $\sim$0.300 kg of Ar at 10 bar, or
alternatively $\sim$0.160 kg of Ne at 10 bar, and energy threshold well below 1
keV, has been built to test this concept. We will describe the main technical
solutions developed, as well as the results from the commissioning phase on
surface. The anticipated sensitivity of this technique might reach
$\sim10^{-44}$ cm$^2$ for low mass ($<10$ GeV) WIMPs, well beyond current
experimental limits in this mass range.
-
As part of the T-REX project, a number of R&D and prototyping activities have
been carried out during the last years to explore the applicability of gaseous
Micromegas-read TPCs in rare event searches like double beta decay (DBD), axion
research and low-mass WIMP searches. In both this and its companion paper, we
compile the main results of the project and give an outlook of application
prospects for this detection technique. While in the companion paper we focus
on axions and WIMPs, in this paper we focus on the results regarding the
measurement of the DBD of $^{136}$Xe in a high pressure Xe (HPXe) TPC.
Particularly relevant are the results obtained in Xe + TMA mixtures with
microbulk Micromegas, showing very promising results in terms of gain,
stability of operation, and energy resolution at pressures up to 10 bar. TMA at
levels of $\sim$1\% reduces electron diffusion by a factor of 10 with respect
to pure Xe, improving the quality of the topological pattern, with a positive
impact on the discrimination capability. Operation with a medium size prototype
(30 cm diameter and 38 cm drift) of 1 kg of Xe at 10 bar in the fiducial
volumen has allowed to test the detection concept in realistic experimental
conditions. Microbulk Micromegas are able to image the DBD ionization signature
with high quality while, at the same time, measuring its energy deposition with
a resolution of at least $\sim$3% FWHM @ Q$_{\beta\beta}$, and probably down to
$\sim$1% FWHM. In addition, first results on the topological signature
information show promising background discrimination capabilities out of reach
of other experimental implementations. Moreover, microbulk Micromegas have very
low levels of intrinsic radioactivity, and offer cost-effective scaling-up
options. All these results demonstrate that Micromegas-read HPXe TPC is a very
competitive technique for the next generation DBD experiments.
-
We report on the design, construction and operation of a low background x-ray
detection line composed of a shielded Micromegas (micromesh gaseous structure)
detector of the microbulk technique. The detector is made from radiopure
materials and is placed at the focal point of a $\sim$~5 cm diameter, 1.3 m
focal-length, cone-approximation Wolter I x-ray telescope (XRT) comprised of
thermally-formed (or "slumped") glass substrates deposited with multilayer
coatings. The system has been conceived as a technological pathfinder for the
future International Axion Observatory (IAXO), as it combines two of the
techniques (optic and detector) proposed in the conceptual design of the
project. It is innovative for two reasons: it is the first time an x-ray optic
has been designed and fabricated specifically for axion research, and the first
time a Micromegas detector has been operated with an x-ray optic. The line has
been installed at one end of the CERN Axion Solar Telescope (CAST) magnet and
is currently looking for solar axions. The combination of the XRT and
Micromegas detector provides the best signal-to-noise ratio obtained so far by
any detection system of the CAST experiment with a background rate of
5.4$\times$10$^{-3}\;$counts per hour in the energy region-of-interest and
signal spot area.
-
We model the response of a state of the art micro-hole single-stage charge
amplication device (`microbulk' Micromegas) in a gaseous atmosphere consisting
of Xenon/trimethylamine at various concentrations and pressures. The amplifying
structure, made with photo-lithographic techniques similar to those followed in
the fabrication of gas electron multipliers (GEMs), consisted of a 100 um-side
equilateral-triangle pattern with 50 um-diameter holes placed at its vertexes.
Once the primary electrons are guided into the holes by virtue of an optimized
field configuration, avalanches develop along the 50 um-height channels etched
out of the original doubly copper-clad polyimide foil. In order to properly
account for the strong field gradients at the holes' entrance as well as for
the fluctuations of the avalanche process (that ultimately determine the
achievable energy resolution), we abandoned the hydrodynamic framework,
resorting to a purely microscopic description of the electron trajectories as
obtained from elementary cross-sections. We show that achieving a satisfactory
description needs additional assumptions about atom-molecule (Penning) transfer
reactions and charge recombination to be made.
-
Solar axions could be converted into x-rays inside the strong magnetic field
of an axion helioscope, triggering the detection of this elusive particle. Low
background x-ray detectors are an essential component for the sensitivity of
these searches. We report on the latest developments of the Micromegas
detectors for the CERN Axion Solar Telescope (CAST), including technological
pathfinder activities for the future International Axion Observatory (IAXO).
The use of low background techniques and the application of discrimination
algorithms based on the high granularity of the readout have led to background
levels below 10$^{-6}$ counts/keV/cm$^2$/s, more than a factor 100 lower than
the first generation of Micromegas detectors. The best levels achieved at the
Canfranc Underground Laboratory (LSC) are as low as 10$^{-7}$
counts/keV/cm$^2$/s, showing good prospects for the application of this
technology in IAXO. The current background model, based on underground and
surface measurements, is presented, as well as the strategies to further reduce
the background level. Finally, we will describe the R&D paths to achieve
sub-keV energy thresholds, which could broaden the physics case of axion
helioscopes.
-
Micromegas detectors are an optimum technological choice for the detection of
low energy x-rays. The low background techniques applied to these detectors
yielded remarkable background reductions over the years, being the CAST
experiment beneficiary of these developments. In this document we report on the
latest upgrades towards further background reductions and better understanding
of the detectors' response. The upgrades encompass the readout electronics, a
new detector design and the implementation of a more efficient cosmic muon veto
system. Background levels below 10$^{-6}$keV$^{-1}$cm$^{-2}$s$^{-1}$ have been
obtained at sea level for the first time, demonstrating the feasibility of the
expectations posed by IAXO, the next generation axion helioscope. Some results
obtained with a set of measurements conducted in the x-ray beam of the CAST
Detector Laboratory will be also presented and discussed.