-
The standard model predicts that, in addition to a proton, an electron, and
an antineutrino, a continuous spectrum of photons is emitted in the $\beta$
decay of the free neutron. We report on the RDK II experiment which measured
the photon spectrum using two different detector arrays. An annular array of
bismuth germanium oxide scintillators detected photons from 14 to 782~keV. The
spectral shape was consistent with theory, and we determined a branching ratio
of 0.00335 $\pm$ 0.00005 [stat] $\pm$ 0.00015 [syst]. A second detector array
of large area avalanche photodiodes directly detected photons from 0.4 to
14~keV. For this array, the spectral shape was consistent with theory, and the
branching ratio was determined to be 0.00582 $\pm$ 0.00023 [stat] $\pm$ 0.00062
[syst]. We report the first precision test of the shape of the photon energy
spectrum from neutron radiative decay and a substantially improved
determination of the branching ratio over a broad range of photon energies.
-
Research efforts ranging from studies of solid helium to searches for a
neutron electric dipole moment require isotopically purified helium with a
ratio of 3He to 4He at levels below that which can be measured using
traditional mass spectroscopy techniques. We demonstrate an approach to such a
measurement using accelerator mass spectroscopy, reaching the 10e-14 level of
sensitivity, several orders of magnitude more sensitive than other techniques.
Measurements of 3He/4He in samples relevant to the measurement of the neutron
lifetime indicate the need for substantial corrections. We also argue that
there is a clear path forward to sensitivity increases of at least another
order of magnitude.
-
The Precision Reactor Oscillation and Spectrum Experiment, PROSPECT, is
designed to make a precise measurement of the antineutrino spectrum from a
highly-enriched uranium reactor and probe eV-scale sterile neutrinos by
searching for neutrino oscillations over meter-long distances. PROSPECT is
conceived as a 2-phase experiment utilizing segmented $^6$Li-doped liquid
scintillator detectors for both efficient detection of reactor antineutrinos
through the inverse beta decay reaction and excellent background
discrimination. PROSPECT Phase I consists of a movable 3-ton antineutrino
detector at distances of 7 - 12 m from the reactor core. It will probe the
best-fit point of the $\nu_e$ disappearance experiments at 4$\sigma$ in 1 year
and the favored region of the sterile neutrino parameter space at $>$3$\sigma$
in 3 years. With a second antineutrino detector at 15 - 19 m from the reactor,
Phase II of PROSPECT can probe the entire allowed parameter space below 10
eV$^{2}$ at 5$\sigma$ in 3 additional years. The measurement of the reactor
antineutrino spectrum and the search for short-baseline oscillations with
PROSPECT will test the origin of the spectral deviations observed in recent
$\theta_{13}$ experiments, search for sterile neutrinos, and conclusively
address the hypothesis of sterile neutrinos as an explanation of the reactor
anomaly.
-
Research reactors host a wide range of activities that make use of the
intense neutron fluxes generated at these facilities. Recent interest in
performing measurements with relatively low event rates, e.g. reactor
antineutrino detection, at these facilities necessitates a detailed
understanding of background radiation fields. Both reactor-correlated and
naturally occurring background sources are potentially important, even at
levels well below those of importance for typical activities. Here we describe
a comprehensive series of background assessments at three high-power research
reactors, including $\gamma$-ray, neutron, and muon measurements. For each
facility we describe the characteristics and identify the sources of the
background fields encountered. The general understanding gained of background
production mechanisms and their relationship to facility features will prove
valuable for the planning of any sensitive measurement conducted therein.
-
This paper summarizes the relevant theoretical developments, outlines some
ideas to improve experimental searches for free neutron-antineutron
oscillations, and suggests avenues for future improvement in the experimental
sensitivity.
-
A meter-long, 23-liter EJ-309 liquid scintillator detector has been
constructed to study the light collection and pulse-shape discrimination
performance of elongated scintillator cells for the PROSPECT reactor
antineutrino experiment. The magnitude and uniformity of light collection and
neutron/gamma discrimination power in the energy range of antineutrino inverse
beta decay products have been studied using gamma and spontaneous fission
calibration sources deployed along the cell long axis. We also study
neutron-gamma discrimination and light collection abilities for differing PMT
and reflector configurations. Key design features for optimizing MeV-scale
response and background rejection capabilities are identified.
-
Reactor antineutrino experiments have the ability to search for neutrino
oscillations independent of reactor flux predictions using a relative
measurement of the neutrino flux and spectrum across a range of baselines. The
range of accessible oscillation parameters are determined by the baselines of
the detector arrangement. We examine the sensitivity of short-baseline
experiments with more than one detector and discuss the optimization of a
second, far detector. The extended reach in baselines of a 2-detector
experiment will improve sensitivity to short-baseline neutrino oscillations
while also increasing the ability to distinguish between 3+1 mixing and other
non-standard models.
-
Reactor antineutrinos are used to study neutrino oscillation, search for
signatures of non-standard neutrino interactions, and to monitor reactor
operation for safeguard applications. The flux and energy spectrum of reactor
antineutrinos can be predicted from the decays of the nuclear fission products.
A comparison of recent reactor calculations with past measurements at baselines
of 10-100m suggests a 5.7% deficit. Precision measurements of reactor
antineutrinos at very short baselines O(1-10 m) can be used to probe this
anomaly and search for possible oscillations into sterile neutrino species.
This paper studies the experimental requirements for a new reactor antineutrino
measurement at very short baselines and calculates the sensitivity of various
scenarios. We conclude that an experiment at a typical research reactor
provides 5{\sigma} discovery potential for the favored oscillation parameter
space with 3 years of data collection.
-
As part of an experiment to measure the spectrum of photons emitted in
beta-decay of the free neutron, we developed and operated a detector consisting
of 12 bismuth germanate (BGO) crystals coupled to avalanche photodiodes (APDs).
The detector was operated near liquid nitrogen temperature in the bore of a
superconducting magnet and registered photons with energies from 5 keV to 1000
keV. To enlarge the detection range, we also directly detected soft X-rays with
energies between 0.2 keV and 20 keV with three large area APDs. The
construction and operation of the detector is presented, as well as information
on operation of APDs at cryogenic temperatures.
-
Background: Time-reversal-invariance violation, or equivalently CP violation,
may explain the observed cosmological baryon asymmetry as well as signal
physics beyond the Standard Model. In the decay of polarized neutrons, the
triple correlation D<J_{n}>\cdot(p_{e}\timesp_{\nu}) is a parity-even,
time-reversal- odd observable that is uniquely sensitive to the relative phase
of the axial-vector amplitude with respect to the vector amplitude. The triple
correlation is also sensitive to possible contributions from scalar and tensor
amplitudes. Final-state effects also contribute to D at the level of 1e-5 and
can be calculated with a precision of 1% or better. Purpose: We have improved
the sensitivity to T-odd, P-even interactions in nuclear beta decay. Methods:
We measured proton-electron coincidences from decays of longitudinally
polarized neutrons with a highly symmetric detector array designed to cancel
the time-reversal-even, parity-odd Standard-Model contributions to polarized
neutron decay. Over 300 million proton-electron coincidence events were used to
extract D and study systematic effects in a blind analysis. Results: We find D
= [-0.94\pm1.89(stat)\pm0.97(sys)]e-4. Conclusions: This is the most sensitive
measurement of D in nuclear beta decay. Our result can be interpreted as a
measurement of the phase of the ratio of the axial-vector and vector coupling
constants (CA/CV= |{\lambda}|exp(i{\phi}_AV)) with {\phi}_AV = 180.012{\deg}
\pm0.028{\deg} (68% confidence level) or to constrain time-reversal violating
scalar and tensor interactions that arise in certain extensions to the Standard
Model such as leptoquarks. This paper presents details of the experiment,
analysis, and systematic- error corrections.
-
This white paper addresses the hypothesis of light sterile neutrinos based on
recent anomalies observed in neutrino experiments and the latest astrophysical
data.
-
We report the results of an improved determination of the triple correlation
$D P \cdot(p_{e}\times p_{\nu})$ that can be used to limit possible
time-reversal invariance in the beta decay of polarized neutrons and constrain
extensions to the Standard Model. Our result is $D=(-0.96\pm 1.89 (stat)\pm
1.01 (sys))\times 10^{-4}$. The corresponding phase between g_A and g_V is
$\phi_{AV} = 180.013^\circ\pm0.028^\circ$ (68 % confidence level). This result
represents the most sensitive measurement of D in beta decay.
-
We describe an apparatus used to measure the triple-correlation term (\D
\hat{\sigma}_n\cdot p_e\times p_\nu) in the beta-decay of polarized neutrons.
The \D-coefficient is sensitive to possible violations of time reversal
invariance. The detector has an octagonal symmetry that optimizes
electron-proton coincidence rates and reduces systematic effects. A beam of
longitudinally polarized cold neutrons passes through the detector chamber,
where a small fraction beta-decay. The final-state protons are accelerated and
focused onto arrays of cooled semiconductor diodes, while the coincident
electrons are detected using panels of plastic scintillator. Details regarding
the design and performance of the proton detectors, beta detectors and the
electronics used in the data collection system are presented. The neutron beam
characteristics, the spin-transport magnetic fields, and polarization
measurements are also described.
-
We describe an experiment that has set new limits on the time reversal
invariance violating D coefficient in neutron beta-decay. The emiT experiment
measured the angular correlation J . p_e x p_p using an octagonal symmetry that
optimizes electron-proton coincidence rates. The result is
D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the
phase of g_A/g_V and limits contributions to T violation due to leptoquarks.
This paper presents details of the experiment, data analysis, and the
investigation of systematic effects.