In a dedicated test setup at the Kamioka Observatory we studied pulse shape
discrimination (PSD) in liquid xenon (LXe) for dark matter searches. PSD in LXe
was based on the observation that scintillation light from electron events was
emitted over a longer period of time than that of nuclear recoil events, and
our method used a simple ratio of early to total scintillation light emission
in a single scintillation event. Requiring an efficiency of 50% for nuclear
recoil retention we reduced the electron background to 7.7\pm1.1(stat)\pm1.2
0.6(sys)\times10-2 at energies between 4.8 and 7.2 keVee and to
7.7\pm2.8(stat)\pm2.5 2.8(sys)\times10-3 at energies between 9.6 and 12 keVee
for a scintillation light yield of 20.9 p.e./keV. Further study was done by
masking some of that light to reduce this yield to 4.6 p.e./keV, the same
method results in an electron event reduction of 2.4\pm0.2(stat)\pm0.3
0.2(sys)\times10-1 for the lower of the energy regions above. We also observe
that in contrast to nuclear recoils the fluctuations in our early to total
ratio for electron events are larger than expected from statistical
fluctuations.
-
We have constructed a GEANT4-based detailed software model of photon
transport in plastic scintillator blocks and have used it to study the NEMO-3
and SuperNEMO calorimeters employed in experiments designed to search for
neutrinoless double beta decay. We compare our simulations to measurements
using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show
that the agreement is improved if wavelength-dependent properties of the
calorimeter are taken into account. In this article, we briefly describe our
modeling approach and results of our studies.
-
Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector
corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is
[2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of
the final state electrons have been studied, such as the energy sum, individual
electron energy, and angular distribution. The 2v nuclear matrix element is
extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints
on 0vbb decay have also been set.
-
In the double beta decay experiment NEMO~3 a precise knowledge of the
background in the signal region is of outstanding importance. This article
presents the methods used in NEMO~3 to evaluate the backgrounds resulting from
most if not all possible origins. It also illustrates the power of the combined
tracking-calorimetry technique used in the experiment.
-
The double beta decay of 100Mo to the 0^+_1 and 2^+_1 excited states of 100Ru
is studied using the NEMO 3 data. After the analysis of 8024 h of data the
half-life for the two-neutrino double beta decay of 100Mo to the excited 0^+_1
state is measured to be T^(2nu)_1/2 = [5.7^{+1.3}_{-0.9}(stat)+/-0.8(syst)]x
10^20 y. The signal-to-background ratio is equal to 3. Information about energy
and angular distributions of emitted electrons is also obtained. No evidence
for neutrinoless double beta decay to the excited 0^+_1 state has been found.
The corresponding half-life limit is T^(0nu)_1/2(0^+ --> 0^+_1) > 8.9 x 10^22 y
(at 90% C.L.).
The search for the double beta decay to the 2^+_1 excited state has allowed
the determination of limits on the half-life for the two neutrino mode
T^(2nu)_1/2(0^+ --> 2^+_1) > 1.1 x 10^21 y (at 90% C.L.) and for the