• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Measurement of shower development and its Moli\`ere radius with a four-plane LumiCal test set-up (1705.03885)

    H. Abramowicz, A. Abusleme, K. Afanaciev, Y. Benhammou, L. Bortko, O. Borysov, M. Borysova, I. Bozovic-Jelisavcic, G. Chelkov, W. Daniluk, D. Dannheim, K. Elsener, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, M. Hempel, H. Henschel, M. Idzik, A. Ignatenko, A. Ishikawa, S. Kananov, O. Karacheban, W. Klempt, S. Kotov, J. Kotula, D. Kozhevnikov, V. Kruchonok, B. Krupa, Sz. Kulis, W. Lange, J. Leonard, T. Lesiak, A. Levy, I. Levy, W. Lohmann, S. Lukic, J. Moron, A. Moszczynski, A.T. Neagu, F.-X. Nuiry, M. Pandurovic, B. Pawlik, T. Preda, O. Rosenblat, A. Sailer, B. Schumm, S. Schuwalow, I. Smiljanic, P. Smolyanskiy, K. Swientek, P. Terlecki, U.I. Uggerhoj, T.N. Wistisen, T. Wojton, H. Yamamoto, L. Zawiejski, I.S. Zgura, A. Zhemchugov
    March 12, 2018 physics.ins-det
    ... ... ... ... ... ...
    A prototype of a luminometer, designed for a future e+e- collider detector, and consisting at present of a four-plane module, was tested in the CERN PS accelerator T9 beam. The objective of this beam test was to demonstrate a multi-plane tungsten/silicon operation, to study the development of the electromagnetic shower and to compare it with MC simulations. The Moli\`ere radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using a parametrization of the shower shape. Very good agreement was found between data and a detailed Geant4 simulation.
  • Higgs Physics at the CLIC Electron-Positron Linear Collider (1608.07538)

    H. Abramowicz, A. Abusleme, K. Afanaciev, N. Alipour Tehrani, C. Balázs, Y. Benhammou, M. Benoit, B. Bilki, J.-J. Blaising, M.J. Boland, M. Boronat, O. Borysov, I. Božović-Jelisavčić, M. Buckland, S. Bugiel, P.N. Burrows, T.K. Charles, W. Daniluk, D. Dannheim, R. Dasgupta, M. Demarteau, M.A. Díaz Gutierrez, G. Eigen, K. Elsener, U. Felzmann, M. Firlej, E. Firu, T. Fiutowski, J. Fuster, M. Gabriel, F. Gaede, I. García, V. Ghenescu, J. Goldstein, S. Green, C. Grefe, M. Hauschild, C. Hawkes, D. Hynds, M. Idzik, G. Kačarević, J. Kalinowski, S. Kananov, W. Klempt, M. Kopec, M. Krawczyk, B. Krupa, M. Kucharczyk, S. Kulis, T. Laštovička, T. Lesiak, A. Levy, I. Levy, L. Linssen, S. Lukić, A.A. Maier, V. Makarenko, J.S. Marshall, V.J. Martin, K. Mei, G. Milutinović-Dumbelović, J. Moroń, A. Moszczyński, D. Moya, R.M. Münker, A. Münnich, A.T. Neagu, N. Nikiforou, K. Nikolopoulos, A. Nürnberg, M. Pandurović, B. Pawlik, E. Perez Codina, I. Peric, M. Petric, F. Pitters, S.G. Poss, T. Preda, D. Protopopescu, R. Rassool, S. Redford, J. Repond, A. Robson, P. Roloff, E. Ros, O. Rosenblat, A. Ruiz-Jimeno, A. Sailer, D. Schlatter, D. Schulte, N. Shumeiko, E. Sicking, F. Simon, R. Simoniello, P. Sopicki, S. Stapnes, R. Ström, J. Strube, K.P. Świentek, M. Szalay, M. Tesař, M.A. Thomson, J. Trenado, U.I. Uggerhøj, N. van der Kolk, E. van der Kraaij, M. Vicente Barreto Pinto, I. Vila, M. Vogel Gonzalez, M. Vos, J. Vossebeld, M. Watson, N. Watson, M.A. Weber, H. Weerts, J.D. Wells, L. Weuste, A. Winter, T. Wojtoń, L. Xia, B. Xu, A.F. Żarnecki, L. Zawiejski, I.-S. Zgura
    June 5, 2017 hep-ph, hep-ex
    ... ... ... ... ... ...
    The Compact Linear Collider (CLIC) is an option for a future e+e- collider operating at centre-of-mass energies up to 3 TeV, providing sensitivity to a wide range of new physics phenomena and precision physics measurements at the energy frontier. This paper is the first comprehensive presentation of the Higgs physics reach of CLIC operating at three energy stages: sqrt(s) = 350 GeV, 1.4 TeV and 3 TeV. The initial stage of operation allows the study of Higgs boson production in Higgsstrahlung (e+e- -> ZH) and WW-fusion (e+e- -> Hnunu), resulting in precise measurements of the production cross sections, the Higgs total decay width Gamma_H, and model-independent determinations of the Higgs couplings. Operation at sqrt(s) > 1 TeV provides high-statistics samples of Higgs bosons produced through WW-fusion, enabling tight constraints on the Higgs boson couplings. Studies of the rarer processes e+e- -> ttH and e+e- -> HHnunu allow measurements of the top Yukawa coupling and the Higgs boson self-coupling. This paper presents detailed studies of the precision achievable with Higgs measurements at CLIC and describes the interpretation of these measurements in a global fit.
  • Physics potential for the measurement of ${\sigma(H\nu\bar{\nu})\times \text{BR}(H\rightarrow\mu^+\mu^-)}$ at the 1.4 TeV CLIC collider (1507.04531)

    G. Milutinović-Dumbelović, I. Božović-Jelisavčić, C. Grefe, G. Kačarević, S. Lukić, M. Pandurović, P. Roloff, I. Smiljanić
    July 21, 2015 hep-ex
    ... ... ... ... ... ...
    The future Compact Linear Collider (CLIC) offers a possibility for a rich precision physics programme, in particular in the Higgs sector through the energy staging. This is the first paper addressing the measurement of the Standard Model Higgs boson decay into two muons at 1.4 TeV CLIC. With respect to similar studies at future linear colliders, this paper includes several novel contributions to the statistical uncertainty of the measurement. The later includes the Equivalent Photon Approximation and realistic forward electron tagging based on energy deposition maps in the forward calorimeters, as well as several processes with the Beamstrahlung photons that results in irreducible contribution to the signal. In addition, coincidence of the Bhabha scattering with the signal and background processes is considered, altering the signal selection efficiency. The study is performed using a fully simulated CLIC_ILD detector model. It is shown that the branching ratio for the Higgs decay into a pair of muons BR(${H\rightarrow\mu^+\mu^-}$) times the Higgs production cross-section in $WW$-fusion $\sigma(H\nu\bar{\nu})$ can be measured with 38% statistical accuracy at ${\sqrt{s} =\text{1.4 TeV}}$, assuming an integrated luminosity of 1.5 ab$^{-1}$ with unpolarised beams. If 80% electron beam polarisation is considered, the statistical uncertainty of the measurement is reduced to 25%. Systematic uncertainties are negligible in comparison to the statistical uncertainty.
  • Measurement of ${\sigma(H\nu_e\bar{\nu_e})\times BR(H\rightarrow ZZ^\ast)}$ and Higgs production in $ZZ$ fusion at a 1.4 TeV CLIC collider (1505.02929)

    G. Milutinović-Dumbelović, I. Božović-Jelisavčić, A. Robson, P. Roloff
    July 19, 2015 hep-ex
    ... ... ... ... ... ...
    This paper presents the potential measurement at 1.4 TeV CLIC of the cross-section (times branching ratio) of the Higgs production via $WW$ fusion with the Higgs subsequently decaying in $ZZ^\ast$, ${\sigma(H\nu_e\bar{\nu_e})\times BR(H\rightarrow ZZ^\ast)}$, and of the Higgs production via $ZZ$ fusion with the Higgs subsequently decaying in $b\bar{b}$, ${\sigma(He{^+}e{^-})\times BR(H\rightarrow b\bar{b})}$. For the $H\rightarrow ZZ^\ast$ decay the hadronic final state, ${ZZ^\ast\rightarrow q\bar{q}q\bar{q}}$, and the semi-leptonic final state, ${ZZ^\ast\rightarrow q\bar{q}l^+l^-}$, are considered. The results show that ${\sigma(H\nu_e\bar{\nu_e})\times BR(H\rightarrow ZZ^\ast)}$ can be measured with a precision of 18.3% and 6% for the hadronic and semi-leptonic channel, respectively. ${\sigma(He{^+}e{^-})\times BR(H\rightarrow b\bar{b})}$ can be measured with a precision of 1.7%. This measurement also contributes to the determination of the Higgs coupling to the $Z$ boson, $g_{H_{ZZ}}$.
  • Performance of fully instrumented detector planes of the forward calorimeter of a Linear Collider detector (1411.4431)

    The FCAL Collaboration: H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, D. Avila, Y. Benhammou, L. Bortko, O. Borysov, M. Bergholz, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, L. Dumitru, K. Elsener, V. Fadeyev, M. Firlej, E. Firu, T. Fiutowski, V. Ghenescu, M. Gostkin, H. Henschel, M. Idzik, A. Ishikawa, S. Kananov, S. Kollowa, S. Kotov, J. Kotula, D. Kozhevnikov, V. Kruchonok, B. Krupa, Sz. Kulis, W. Lange, T. Lesiak, A. Levy, I. Levy, W. Lohmann, S. Lukic, C. Milke, J. Moron, A. Moszczynski, A.T. Neagu, O. Novgorodova, K. Oliwa, M. Orlandea, M. Pandurovic, B. Pawlik, T. Preda, D. Przyborowski, O. Rosenblat, A. Sailer, Y. Sato, B. Schumm, S. Schuwalow, I. Smiljanic, P. Smolyanskiy, K. Swientek, E. Teodorescu, P. Terlecki, W. Wierba, T. Wojton, S. Yamaguchi, H. Yamamoto, L. Zawiejski, I.S. Zgura, A. Zhemchugov
    June 1, 2015 physics.ins-det
    ... ... ... ... ... ...
    Detector-plane prototypes of the very forward calorimetry of a future detector at an e+e- collider have been built and their performance was measured in an electron beam. The detector plane comprises silicon or GaAs pad sensors, dedicated front-end and ADC ASICs, and an FPGA for data concentration. Measurements of the signal-to-noise ratio and the response as a function of the position of the sensor are presented. A deconvolution method is successfully applied, and a comparison of the measured shower shape as a function of the absorber depth with a Monte-Carlo simulation is given.
  • Physics potential for the measurement of sigma(Hvv)*BR(H->mu+mu-) at a 1.4 TeV CLIC collider (1412.5791)

    G. Milutinović-Dumbelović, I. Božović-Jelisavčić, C. Grefe, S. Lukić, M. Pandurović, P. Roloff
    Dec. 18, 2014 hep-ex
    ... ... ... ... ... ...
    The potential for the measurement of the branching ratio of the Standard Model-like Higgs boson decay into a mu+mu- pair at 1.4 TeV CLIC is analysed. The study is performed using the fully simulated CLIC_ILD detector concept, taking into consideration all the relevant physics and the beam-induced backgrounds. Despite the very low branching ratio of the H->mu+mu- decay, we show that the product of the branching ratio times the Higgs production cross section can be measured with a statistical uncertainty of 38 percent, assuming an integrated luminosity of 1.5 ab^-1 collected in five years of the detector operation at the 1.4 TeV CLIC with unpolarised beams. With polarised beams (-80%, +30%), the statistical uncertainty is better than 25%.
  • ECFA Detector R&D Panel, Review Report (1411.4924)

    The FCAL Collaboration: H. Abramowicz, A. Abusleme, K. Afanaciev, J. Aguilar, E. Alvarez, P. Bambade, L. Bortko, I. Bozovic-Jelisavcic, E. Castro, G. Chelkov, C. Coca, W. Daniluk, A. Dragone, L. Dumitru, K. Elsener, I. Emeliantchik, E. Firu, J. Fischer, T. Fiutowski, V. Ghenescu, M. Gostkin, G. Grzelak, G. Haller, H. Henschel, A. Ignatenko, M. Idzik, K. Ito, S. Kananov, E. Kielar, S. Kollowa, J. Kotula, Z. Krumstein, B. Krupa, S. Kulis, W. Lange, A. Levy, I. Levy, L. Linssen, W. Lohmann, S. Lukic, J. Moron, A. Moszczynski, U. Nauenberg, A. Neagu, O. Novgorodova, F.-X. Nuiry, M. Ohlerich, M. Orlandea, G. Oleinik, K. Oliwa, A. Olshevski, M. Pandurovic, B. Pawlik, T. Preda, D. Przyborowski, Y. Sato, I. Sadeh, A. Sailer, B. Schumm, S. Schuwalow, R. Schwartz, I. Smiljanic, K. Swientek, Y. Takubo, E. Teodorescu, W. Wierba, H. Yamamoto, L. Zawiejski, T.-S. Zgura, J. Zhang
    Nov. 19, 2014 physics.ins-det
    ... ... ... ... ... ...
    Two special calorimeters are foreseen for the instrumentation of the very forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to measure the rate of low angle Bhabha scattering events with a precision better than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle calorimeter (BeamCal). The latter will be hit by a large amount of beamstrahlung remnants. The intensity and the spatial shape of these depositions will provide a fast luminosity estimate, as well as determination of beam parameters. The sensors of this calorimeter must be radiation-hard. Both devices will improve the e.m. hermeticity of the detector in the search for new particles. Finely segmented and very compact electromagnetic calorimeters will match these requirements. Due to the high occupancy, fast front-end electronics will be needed. Monte Carlo studies were performed to investigate the impact of beam-beam interactions and physics background processes on the luminosity measurement, and of beamstrahlung on the performance of BeamCal, as well as to optimise the design of both calorimeters. Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and prototypes are available. Prototypes of sensor planes fully assembled with readout electronics have been studied in electron beams.
  • Precision luminosity measurement at ILC (1403.7348)

    I. Bozovic-Jelisavcic, S. Lukic, M. Pandurovic, I. Smiljanic
    March 28, 2014 hep-ph, physics.acc-ph
    In these proceedings a novel approach to deal with the beam-induced effects in luminosity measurement is presented. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainties can be reduced to the permille level independently of a precision with which the beam parameters are known. Specific event selection combined with the corrective methods we introduce, leads to the systematic uncertainty from the beam-induced effects to be at a few permille level in the peak region above the 80% of the nominal centre-of-mass energies at ILC.
  • SM-like Higgs decay into two muons at 1.4 TeV CLIC (1403.6695)

    I. Bozovic-Jelisavcic, S. Lukic, G. Milutinovic-Dumbelovic, M. Pandurovic
    March 26, 2014 hep-ph, hep-ex
    The branching fraction measurement of the SM-like Higgs boson decay into two muons at 1.4 TeV CLIC will be described in this paper contributed to the LCWS13. The study is performed in the fully simulated ILD detector concept for CLIC, taking into consideration all the relevant physics and the beam-induced backgrounds, as well as the instrumentation of the very forward region to tag the high-energy electrons. Higgs couplings are known to be sensitive to BSM physics and we prove that BR times the Higgs production cross section can be measured with approximately 35.5% statistical accuracy in four years of the CLIC operation at 1.4 TeV centre-of-mass energy with unpolarised beams. The result is preliminary as the equivalent photon approximation is not considered in the cross-section calculations. This study complements the Higgs physics program foreseen at CLIC.
  • Luminosity measurement at ILC (1304.4082)

    I. Bozovic-Jelisavcic, S. Lukic, G. Milutinovic Dumbelovic, M. Pandurovic, I. Smiljanic
    Aug. 21, 2013 hep-ex, physics.acc-ph
    ... ... ... ... ... ...
    In this paper we describe a method of luminosity measurement at the future linear collider ILC that estimates and corrects for the impact of the dominant sources of systematic uncertainty originating from the beam-induced effects and the background from physics processes. Based on the relativistic kinematics of the collision frame of the Bhabha process, the beam-beam related uncertainty is reduced to a permille independently of the precision with which the beam parameters are known. With the specific event selection, different from the isolation cuts based on topology of the signal used at LEP, combined with the corrective methods we introduce, the overall systematic uncertainty in the peak region above 80% of the nominal center-of-mass energy meets the physics requirements to be at the few permille level at all ILC energies.
  • Physics background at ILC at 500GeV and 1TeV (1301.2494)

    M. Pandurovic, I. Bozovic-Jelisavcic
    Jan. 11, 2013 hep-ex, physics.ins-det
    Measurement of the integrated luminosity at the International Linear Collider (ILC) will be accomplished by counting the rate of small angle Bhabha scattering events. The physics requirements for ILC set the constraint on the relative precision of the luminosity measurement to be of a permille order. The required precision can be achieved by construction of a fine granulated electromagnetic calorimeter of high energy and polar angle resolution and by sufficient experimental control of numerous systematic effects. One of the leading systematic effects in luminosity measurement is the background originating from four-fermion processes, referred to as the physics background. In this paper a possible selection strategy to measure the luminosity is proposed from the perspective of optimal signal to background separation.
  • Luminosity Measurement at ILC (1006.2539)

    I. Bozovic-Jelisavcic, H. Abramowicz, P. Bambade, T. Jovin, M. Pandurovic, B. Pawlik, C. Rimbault, I. Sadeh, I. Smiljanic
    June 13, 2010 hep-ex, physics.ins-det, physics.acc-ph
    More than twenty institutes join the FCAL Collaboration in study of design of the very forward region of a detector for ILC and CLIC. Of particular importance is an accurate luminosity measurement to the level of 10-3, a requirement driven by the potential for precision physics at a future linear collider. In this paper, the method for luminosity measurement, requirements on luminometer and its integration in the forward region are presented. The impact of several effects contributing to the systematic uncertainty of luminosity measurement is given.
  • Measurement of Trilinear Gauge Couplings at a gamma-gamma and e-gamma Collider (hep-ph/0210308)

    I. Bozovic-Jelisavcic, K. Moenig, J. Sekaric
    Oct. 23, 2002 hep-ph
    The processes gamma gamma -> WW and e gamma -> nu W are sensitive to triple gauge boson interactions. Both reactions have been simulated for hadronically decaying W-bosons and the sensitivity to anomalous couplings has been estimated.