• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • Charge mobility of discotic mesophases: A multiscale quantum/classical study (cond-mat/0701382)

    J. Kirkpatrick, V. Marcon, J. Nelson, K. Kremer, D. Andrienko
    Jan. 16, 2007 cond-mat.soft, cond-mat.mtrl-sci
    A correlation is established between the molecular structure and charge mobility of discotic mesophases of hexabenzocoronene derivatives by combining electronic structure calculations, Molecular Dynamics, and kinetic Monte Carlo simulations. It is demonstrated that this multiscale approach can provide an accurate ab-initio description of charge transport in organic materials.
  • The ZEPLIN-III dark matter detector: instrument design, manufacture and commissioning (astro-ph/0605500)

    D. Yu. Akimov, G. J. Alner, H. M. Araujo, A. Bewick, C. Bungau, A. A. Burenkov, M. J. Carson, V. Chepel, D. Cline, D. Davidge, J. C. Davies, E. Daw, J. Dawson, T. Durkin, B. Edwards, T. Gamble, C. Chag, R. J. Hollingworth, A. S. Howard, W. G. Jones, M. Joshi, J. Kirkpatrick, A. Kovalenko, V. A. Kudryavtsev, I. S. Kuznetsov, T. Lawson, V. N. Lebedenko, J. D. Lewin, P. Lightfoot, A. Lindote, I. Liubarsky, M. I. Lopes, R. Luscher, J. E. McMillan, B. Morgan, D. Muna, A. S. Murphy, F. Neves, G. G. Nicklin, S. M. Paling, D. Muna, J. Pinto da Cunha, S. J. S. Plank, R. Preece, J. J. Quenby, M. Robinson, C. Silva, V. N. Solovov, N. J. T. Smith, P. F. Smith, N. J. C. Spooner, V. Stekhanov, T. J. Sumner, C. Thorne, D. R. Tovey, E. Tziaferi, R. J. Walker, H. Wang, J. White & F. Wolfs
    May 19, 2006 astro-ph
    We present details of the technical design and manufacture of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures both the scintillation light and the ionisation charge generated in the liquid by interacting particles and radiation. The instrument design is driven by both the physics requirements and by the technology requirements surrounding the use of liquid xenon. These include considerations of key performance parameters, such as the efficiency of scintillation light collection, restrictions placed on the use of materials to control the inherent radioactivity levels, attainment of high vacuum levels and chemical contamination control. The successful solution has involved a number of novel design and manufacturing features which will be of specific use to future generations of direct dark matter search experiments as they struggle with similar and progressively more demanding requirements.
  • Measurements of the Generalized Electric and Magnetic Polarizabilities of the Proton at Low Q2 Using the VCS Reaction (nucl-ex/0605009)

    P. Bourgeois, Y. Sato, J. Shaw, R. Alarcon, A. M. Bernstein, W. Bertozzi, T. Botto, J. Calarco, F. Casagrande, M. O. Distler, K. Dow, M. Farkondeh, S. Georgakopoulos, S. Gilad, R. Hicks, M. Holtrop, A. Hotta, X. Jiang, A. Karabarbounis, J. Kirkpatrick, S. Kowalski, R. Milner, R. Miskimen, I. Nakagawa, C. N. Papanicolas, A. J. Sarty, S. Sirca, E. Six, N. F. Sparveris, S. Stave, E. Stiliaris, T. Tamae, G. Tsentalovich, C. Tschalaer, W. Turchinetz, Z.-L. Zhou, T. Zwart
    May 10, 2006 nucl-ex
    The mean square polarizability radii of the proton have been measured for the first time in a virtual Compton scattering experiment performed at the MIT-Bates out-of-plane scattering facility. Response functions and polarizabilities obtained from a dispersion analysis of the data at Q2=0.06 GeV2/c2 are in agreement with O(p3) heavy baryon chiral perturbation theory. The data support the dominance of mesonic effects in the polarizabilities, and the increase of beta with increasing Q2 is evidence for the cancellation of long-range diamagnetism by short-range paramagnetism from the pion cloud.
  • The ZEPLIN-III dark matter detector: performance study using an end-to-end simulation tool (astro-ph/0603243)

    H. M. Araujo, D. Yu. Akimov, G. J. Alner, A. Bewick, C. Bungau, B. Camanzi, M. J. Carson, V. Chepel, H. Chagani, D. Davidge, J. C. Davies, E. Daw, J. Dawson, T. Durkin, B. Edwards, T. Gamble, C. Ghag, R. Hollingworth, A. S. Howard, W. G. Jones, M. Joshi, J. Kirkpatrick, A. Kovalenko, V. A. Kudryavtsev, V. N. Lebedenko, T. Lawson, J. D. Lewin, P. Lightfoot, A. Lindote, I. Liubarsky, M. I. Lopes, R. Luscher, P. Majewski, K. Mavrokoridis, J. McMillan, B. Morgan, D. Muna, A. S. Murphy, F. Neves, G. Nicklin, S. Paling, J. Pinto da Cunha, R. Preece, J. J. Quenby, M. Robinson, C. Silva, V. N. Solovov, N. J. T. Smith, P. F. Smith, N. J. C. Spooner, V. Stekhanov, T. J. Sumner, D. R. Tovey, C. Thorne, E. Tziaferi, R. J. Walker
    March 9, 2006 astro-ph
    We present results from a GEANT4-based Monte Carlo tool for end-to-end simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase detector which measures both the scintillation light and the ionisation charge generated in liquid xenon by interacting particles and radiation. The software models the instrument response to radioactive backgrounds and calibration sources, including the generation, ray-tracing and detection of the primary and secondary scintillations in liquid and gaseous xenon, and subsequent processing by data acquisition electronics. A flexible user interface allows easy modification of detector parameters at run time. Realistic datasets can be produced to help with data analysis, an example of which is the position reconstruction algorithm developed from simulated data. We present a range of simulation results confirming the original design sensitivity of a few times $10^{-8}$ pb to the WIMP-nucleon cross-section.