A prototype of a luminometer, designed for a future e+e- collider detector,
and consisting at present of a four-plane module, was tested in the CERN PS
accelerator T9 beam. The objective of this beam test was to demonstrate a
multi-plane tungsten/silicon operation, to study the development of the
electromagnetic shower and to compare it with MC simulations. The Moli\`ere
radius has been determined to be 24.0 +/- 0.6 (stat.) +/- 1.5 (syst.) mm using
a parametrization of the shower shape. Very good agreement was found between
data and a detailed Geant4 simulation.
-
Detector-plane prototypes of the very forward calorimetry of a future
detector at an e+e- collider have been built and their performance was measured
in an electron beam. The detector plane comprises silicon or GaAs pad sensors,
dedicated front-end and ADC ASICs, and an FPGA for data concentration.
Measurements of the signal-to-noise ratio and the response as a function of the
position of the sensor are presented. A deconvolution method is successfully
applied, and a comparison of the measured shower shape as a function of the
absorber depth with a Monte-Carlo simulation is given.
-
Two special calorimeters are foreseen for the instrumentation of the very
forward region of an ILC or CLIC detector; a luminometer (LumiCal) designed to
measure the rate of low angle Bhabha scattering events with a precision better
than 10$^{-3}$ at the ILC and 10$^{-2}$ at CLIC, and a low polar-angle
calorimeter (BeamCal). The latter will be hit by a large amount of
beamstrahlung remnants. The intensity and the spatial shape of these
depositions will provide a fast luminosity estimate, as well as determination
of beam parameters. The sensors of this calorimeter must be radiation-hard.
Both devices will improve the e.m. hermeticity of the detector in the search
for new particles. Finely segmented and very compact electromagnetic
calorimeters will match these requirements. Due to the high occupancy, fast
front-end electronics will be needed. Monte Carlo studies were performed to
investigate the impact of beam-beam interactions and physics background
processes on the luminosity measurement, and of beamstrahlung on the
performance of BeamCal, as well as to optimise the design of both calorimeters.
Dedicated sensors, front-end and ADC ASICs have been designed for the ILC and
prototypes are available. Prototypes of sensor planes fully assembled with
readout electronics have been studied in electron beams.
-
In this Technical Design Report (TDR) we describe the SuperB detector that
was to be installed on the SuperB e+e- high luminosity collider. The SuperB
asymmetric collider, which was to be constructed on the Tor Vergata campus near
the INFN Frascati National Laboratory, was designed to operate both at the
Upsilon(4S) center-of-mass energy with a luminosity of 10^{36} cm^{-2}s^{-1}
and at the tau/charm production threshold with a luminosity of 10^{35}
cm^{-2}s^{-1}. This high luminosity, producing a data sample about a factor 100
larger than present B Factories, would allow investigation of new physics
effects in rare decays, CP Violation and Lepton Flavour Violation. This
document details the detector design presented in the Conceptual Design Report
(CDR) in 2007. The R&D and engineering studies performed to arrive at the full
detector design are described, and an updated cost estimate is presented.
A combination of a more realistic cost estimates and the unavailability of
funds due of the global economic climate led to a formal cancelation of the
project on Nov 27, 2012.
-
The EUDET-project was launched to create an infrastructure for developing and
testing new and advanced detector technologies to be used at a future linear
collider. The aim was to make possible experimentation and analysis of data for
institutes, which otherwise could not be realized due to lack of resources. The
infrastructure comprised an analysis and software network, and instrumentation
infrastructures for tracking detectors as well as for calorimetry.
-
LumiCal will be the luminosity calorimeter for the proposed International
Large Detector of the International Linear Collider (ILC). The ILC physics
program requires the integrated luminosity to be measured with a relative
precision on the order of 10e-3, or 10e-4 when running in GigaZ mode.
Luminosity will be determined by counting Bhabha scattering events coincident
in the two calorimeter modules placed symmetrically on opposite sides of the
interaction point. To meet these goals, the energy resolution of the
calorimeter must be better than 1.5% at high energies. LumiCal has been
designed as a 30-layer sampling calorimeter with tungsten as the passive
material and silicon as the active material. Monte Carlo simulation using the
Geant4 software framework has been used to identify design elements which
adversely impact energy resolution and correct for them without loss of
statistics. BeamCal, covering polar angles smaller than LumiCal, will serve for
beam tuning, luminosity optimisation and high energy electron detection.
Secondly, prototypes of the sensors and electronics for both detectors have
been evaluated during beam tests, the results of which are also presented here.