-
This release includes data and information necessary to perform independent
analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294
[nucl-ex]. Data is shared in a binned, text-based format, including both
"signal" and "background" regions, so that counts and associated uncertainties
can be quantitatively calculated for the purpose of separate analyses. This
document describes the included information and its format, offering some
guidance on use of the data. Accompanying code examples show basic interaction
with the data using Python.
-
The primary goal of the COHERENT collaboration is to measure and study
coherent elastic neutrino-nucleus scattering (CEvNS) using the high-power,
few-tens-of-MeV, pulsed source of neutrinos provided by the Spallation Neutron
Source (SNS) at Oak Ridge National Laboratory (ORNL). The COHERENT
collaboration reported the first detection of CEvNS [Akimov:2017ade] using a
CsI[Na] detector. At present the collaboration is deploying four detector
technologies: a CsI[Na] scintillating crystal, p-type point-contact germanium
detectors, single-phase liquid argon, and NaI[Tl] crystals. All detectors are
located in the neutron-quiet basement of the SNS target building at distances
20-30 m from the SNS neutrino source. The simultaneous measurement in all four
COHERENT detector subsystems will test the $N^2$ dependence of the cross
section and search for new physics. In addition, COHERENT is measuring
neutrino-induced neutrons from charged- and neutral-current neutrino
interactions on nuclei in shielding materials, which represent a non-negligible
background for CEvNS as well as being of intrinsic interest. The Collaboration
is planning as well to look for charged-current interactions of relevance to
supernova and weak-interaction physics. This document describes concisely the
COHERENT physics motivations, sensitivity, and next plans for measurements at
the SNS to be accomplished on a few-year timescale.
-
The precise value of the mean neutron lifetime, $\tau_n$, plays an important
role in nuclear and particle physics and cosmology. It is a key input for
predicting the ratio of protons to helium atoms in the primordial universe and
is used to search for new physics beyond the Standard Model of particle
physics. There is a 3.9 standard deviation discrepancy between $\tau_n$
measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2
s) and by counting surviving ultracold neutrons stored for different storage
times in a material trap (878.5$\pm$0.8 s). The experiment described here
eliminates loss mechanisms present in previous trap experiments by levitating
polarized ultracold neutrons above the surface of an asymmetric storage trap
using a repulsive magnetic field gradient so that the stored neutrons do not
interact with material trap walls and neutrons in quasi-stable orbits rapidly
exit the trap. As a result of this approach and the use of a new in situ
neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2
(sys) s) is the first modern measurement of $\tau_n$ that does not require
corrections larger than the quoted uncertainties.
-
The coherent elastic scattering of neutrinos off nuclei has eluded detection
for four decades, even though its predicted cross-section is the largest by far
of all low-energy neutrino couplings. This mode of interaction provides new
opportunities to study neutrino properties, and leads to a miniaturization of
detector size, with potential technological applications. We observe this
process at a 6.7-sigma confidence level, using a low-background, 14.6-kg
CsI[Na] scintillator exposed to the neutrino emissions from the Spallation
Neutron Source (SNS) at Oak Ridge National Laboratory. Characteristic
signatures in energy and time, predicted by the Standard Model for this
process, are observed in high signal-to-background conditions. Improved
constraints on non-standard neutrino interactions with quarks are derived from
this initial dataset.
-
The neutron lifetime is important in understanding the production of light
nuclei in the first minutes after the big bang and it provides basic
information on the charged weak current of the standard model of particle
physics. Two different methods have been used to measure the neutron lifetime:
disappearance measurements using bottled ultracold neutrons and decay rate
measurements using neutron beams. The best measurements using these two
techniques give results that differ by nearly 4 standard deviations. In this
paper we describe a new method for measuring surviving neutrons in neutron
lifetime measurements using bottled ultracold neutrons that provides better
characterization of systematic uncertainties and enables higher precision than
previous measurement techniques. We present results obtained using our method.
-
The UCN$\tau$ experiment is designed to measure the lifetime $\tau_{n}$ of
the free neutron by trapping ultracold neutrons (UCN) in a
magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach
array confines low-field-seeking UCN within the apparatus, and a set of
electromagnetic coils in a toroidal geometry provide a background "holding"
field to eliminate depolarization-induced UCN loss caused by magnetic field
nodes. We present a measurement of the storage time $\tau_{store}$ of the trap
by storing UCN for various times, and counting the survivors. The data are
consistent with a single exponential decay, and we find $\tau_{store}=860\pm19$
s: within $1 \sigma$ of current global averages for $\tau_{n}$. The storage
time with the holding field deactiveated is found to be $\tau_{store}=470 \pm
160$ s; this decreased storage time is due to the loss of UCN which undergo
Majorana spin-flips while being stored. We discuss plans to increase the
statistical sensitivity of the measurement and investigate potential systematic
effects.