LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With construction well underway, LZ
is on track for underground installation at SURF in 2019 and will start
collecting data in 2020.
-
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle
interactions with a detector containing a total of 10 tonnes of liquid xenon
within a double-vessel cryostat. The large mass and proximity of the cryostat
to the active detector volume demand the use of material with extremely low
intrinsic radioactivity. We report on the radioassay campaign conducted to
identify suitable metals, the determination of factors limiting radiopure
production, and the selection of titanium for construction of the LZ cryostat
and other detector components. This titanium has been measured with activities
of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg,
$^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm
0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL).
Such low intrinsic activities, which are some of the lowest ever reported for
titanium, enable its use for future dark matter and other rare event searches.
Monte Carlo simulations have been performed to assess the expected background
contribution from the LZ cryostat with this radioactivity. In 1,000 days of
WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute
only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
-
The first searches for axions and axion-like particles with the Large
Underground Xenon (LUX) experiment are presented. Under the assumption of an
axio-electric interaction in xenon, the coupling constant between axions and
electrons, gAe is tested, using data collected in 2013 with an exposure
totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood
ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90%
C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper
limit in coupling corresponds to an upper limit on axion mass of 0.12
eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are
excluded. For galactic axion-like particles, values of gAe larger than 4.2
$\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16
keV/c$^{2}$. These are the most stringent constraints to date for these
interactions.
-
In this Technical Design Report (TDR) we describe the LZ detector to be built
at the Sanford Underground Research Facility (SURF). The LZ dark matter
experiment is designed to achieve sensitivity to a WIMP-nucleon
spin-independent cross section of three times ten to the negative forty-eighth
square centimeters.
-
This work presents an analysis of monoenergetic electronic recoil peaks in
the dark-matter-search and calibration data from the first underground science
run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and
light yields for electronic recoil energies between 5.2 and 661.7 keV are
measured, as well as the energy resolution for the LUX detector at those same
energies. Additionally, there is an interpretation of existing measurements and
descriptions of electron-ion recombination fluctuations in liquid xenon as
limiting cases of a more general liquid xenon re- combination fluctuation
model. Measurements of the standard deviation of these fluctuations at
monoenergetic electronic recoil peaks exhibit a linear dependence on the number
of ions for energy deposits up to 661.7 keV, consistent with previous LUX
measurements between 2-16 keV with $^3$H. We highlight similarities in liquid
xenon recombination for electronic and nuclear recoils with a comparison of
recombination fluctuations measured with low-energy calibration data.
-
The Large Underground Xenon (LUX) experiment operates at the Sanford
Underground Research Facility to detect nuclear recoils from the hypothetical
Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid
xenon typically contains trace amounts of the noble radioactive isotopes
$^{85}$Kr and $^{39}$Ar that are not removed by the {\em in situ} gas
purification system. The decays of these isotopes at concentrations typical of
research-grade xenon would be a dominant background for a WIMP search
exmperiment. To remove these impurities from the liquid xenon, a
chromatographic separation system based on adsorption on activated charcoal was
built. 400\,kg of xenon was processed, reducing the average concentration of
krypton from 130\,ppb to 3.5\,ppt as measured by a cold-trap assisted mass
spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed
twice and reduced to an upper limit of 0.2 ppt.
-
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils resulting from interactions with dark matter particles.
Signals from the detector are processed with an FPGA-based digital trigger
system that analyzes the incoming data in real-time, with just a few
microsecond latency. The system enables first pass selection of events of
interest based on their pulse shape characteristics and 3D localization of the
interactions. It has been shown to be >99% efficient in triggering on S2
signals induced by only few extracted liquid electrons. It is continuously and
reliably operating since its full underground deployment in early 2013. This
document is an overview of the systems capabilities, its inner workings, and
its performance.