• Login
    Sort by: Relevance Date Users's collections Twitter
    Group by: Day Week Month Year All time
Based on the idea and the provided source code of Andrej Karpathy (arxiv-sanity)
2:3 1:1 3:2
  • MIMAC: MIcro-tpc MAtrix of Chambers for dark matter directional detection (1311.0616)

    D. Santos, G. Bosson, J.L. Bouly, O. Bourrion, Ch. Fourel, O. Guillaudin, J. Lamblin, F. Mayet, J.F. Muraz, J.P. Richer, Q. Riffard, L. Lebreton, D. Maire, J. Busto, J. Brunner, D. Fouchez
    Nov. 4, 2013 physics.ins-det, astro-ph.CO
    ... ... ... ... ... ...
    Directional detection of non-baryonic Dark Matter is a promising search strategy for discriminating WIMP events from neutrons, the ultimate background for dark matter direct detection. This strategy requires both a precise measurement of the energy down to a few keV and 3D reconstruction of tracks down to a few mm. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a special developed fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The first bi-chamber prototype has been installed at Modane, underground laboratory in June 2012. The first undergournd background events, the gain stability and calibration are shown. The first spectrum of nuclear recoils showing 3D tracks coming from the radon progeny is presented.
  • MIMAC: A micro-tpc matrix for dark matter directional detection (1304.2255)

    D. Santos, J. Billard, G. Bosson, J.L. Bouly, O. Bourrion, C. Fourel, O. Guillaudin, J. Lamblin, J.F. Muraz, F. Mayet, J.P. Richer, Q. Riffard, E. Ferrer, I. Giomataris, F.J. Iguaz, L. Lebreton, D. Maire
    April 8, 2013 physics.ins-det, astro-ph.CO
    ... ... ... ... ... ...
    The dark matter directional detection opens a new field in cosmology bringing the possibility to build a map of nuclear recoils that would be able to explore the galactic dark matter halo giving access to a particle characterization of such matter and the shape of the halo. The MIMAC (MIcro-tpc MAtrix of Chambers) collaboration has developed in the last years an original prototype detector based on the direct coupling of large pixelized micromegas with a devoted fast self-triggered electronics showing the feasibility of a new generation of directional detectors. The discovery potential of this search strategy is discussed and illustrated. In June 2012, the first bi-chamber prototype has been installed at Modane Underground Laboratory (LSM) and the first underground background events, the gain stability and calibration are shown.
  • Micromegas detector developments for MIMAC (1109.1675)

    E. Ferrer-Ribas, D. Attié, D. Calvet, P. Colas, F. Druillole, Y. Giomataris, F.J. Iguaz, J.P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J.L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J.P. Richer, D. Santos, C. Golabek, L. Lebreton
    Sept. 12, 2011 physics.ins-det, astro-ph.IM
    ... ... ... ... ... ...
    The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC. The recent Micromegas efforts towards building a large size detector will be described, in particular the characterization measurements of a prototype detector of 10 $\times$ 10 cm$^2$ with a 2 dimensional readout plane. Track reconstruction with alpha particles will be shown.
  • Design and construction of a Cherenkov imager for charge measurement of nuclear cosmic rays (1103.1321)

    O. Bourrion, Ch. Bernard, D. Bondoux, J.L. Bouly, J. Bouvier, B. Boyer, M. Brinet, M. Buenerd, G. Damieux, L. Derome, L. Eraud, R. Foglio, D. Fombaron, D. Grondin, M. H. Lee, L. Lutz, M. Marton, A. Menchaca-Rocha, A. Pelissier, J.N. Périé, A. Putze, S. Roudier, Y. Sallaz-Damaz, E. S. Seo, J.P. Scordilis, Y. S. Yoon
    May 18, 2011 astro-ph.IM
    ... ... ... ... ... ...
    A proximity focusing Cherenkov imager called CHERCAM, has been built for the charge measurement of nuclear cosmic rays with the CREAM instrument. It consists of a silica aerogel radiator plane across from a detector plane equipped with 1,600 1" diameter photomultipliers. The two planes are separated by a ring expansion gap. The Cherenkov light yield is proportional to the charge squared of the incident particle. The expected relative light collection accuracy is in the few percents range. It leads to an expected single element separation over the range of nuclear charge Z of main interest 1 < Z < 26. CHERCAM is designed to fly with the CREAM balloon experiment. The design of the instrument and the implemented technical solutions allowing its safe operation in high altitude conditions (radiations, low pressure, cold) are presented.
  • Micromegas detector developments for Dark Matter directional detection with MIMAC (1105.2056)

    F.J. Iguaz, D. Attié, D. Calvet, P. Colas, F. Druillole, E. Ferrer-Ribas, I. Giomataris, J.P. Mols, J. Pancin, T. Papaevangelou, J. Billard, G. Bosson, J.L. Bouly, O. Bourrion, Ch. Fourel, C. Grignon, O. Guillaudin, F. Mayet, J.P. Richer, D. Santos, C. Golabek, L. Lebreton
    May 10, 2011 physics.ins-det
    ... ... ... ... ... ...
    The aim of the MIMAC project is to detect non-baryonic Dark Matter with a directional TPC using a high precision Micromegas readout plane. We will describe in detail the recent developments done with bulk Micromegas detectors as well as the characterisation measurements performed in an Argon(95%)-Isobutane(5%) mixture. Track measurements with alpha particles will be shown.