The next-generation Enriched Xenon Observatory (nEXO) is a proposed
experiment to search for neutrinoless double beta ($0\nu\beta\beta$) decay in
$^{136}$Xe with a target half-life sensitivity of approximately $10^{28}$ years
using $5\times10^3$ kg of isotopically enriched liquid-xenon in a time
projection chamber. This improvement of two orders of magnitude in sensitivity
over current limits is obtained by a significant increase of the $^{136}$Xe
mass, the monolithic and homogeneous configuration of the active medium, and
the multi-parameter measurements of the interactions enabled by the time
projection chamber. The detector concept and anticipated performance are
presented based upon demonstrated realizable background rates.
-
We present the first limits on inelastic electron-scattering dark matter and
dark photon absorption using a prototype SuperCDMS detector having a charge
resolution of 0.1 electron-hole pairs (CDMS HVeV, a 0.93 gram CDMS HV device).
These electron-recoil limits significantly improve experimental constraints on
dark matter particles with masses as low as 1 MeV/$\mathrm{c^2}$. We
demonstrate a sensitivity to dark photons competitive with other leading
approaches but using substantially less exposure (0.49 gram days). These
results demonstrate the scientific potential of phonon-mediated semiconductor
detectors that are sensitive to single electronic excitations.
-
This release includes data and information necessary to perform independent
analyses of the COHERENT result presented in Akimov et al., arXiv:1708.01294
[nucl-ex]. Data is shared in a binned, text-based format, including both
"signal" and "background" regions, so that counts and associated uncertainties
can be quantitatively calculated for the purpose of separate analyses. This
document describes the included information and its format, offering some
guidance on use of the data. Accompanying code examples show basic interaction
with the data using Python.
-
The \MJ\ Collaboration is operating an array of high purity Ge detectors to
search for neutrinoless double-beta decay in $^{76}$Ge. The \MJ\ \DEM\
comprises 44.1~kg of Ge detectors (29.7 kg enriched in $^{76}$Ge) split between
two modules contained in a low background shield at the Sanford Underground
Research Facility in Lead, South Dakota. Here we present results from data
taken during construction, commissioning, and the start of full operations. We
achieve unprecedented energy resolution of 2.5 keV FWHM at \qval\ and a very
low background with no observed candidate events in 10 kg yr of enriched Ge
exposure, resulting in a lower limit on the half-life of $1.9\times10^{25}$ yr
(90\% CL). This result constrains the effective Majorana neutrino mass to below
240 to 520 meV, depending on the matrix elements used. In our experimental
configuration with the lowest background, the background is $4.0_{-2.5}^{+3.1}$
counts/(FWHM t yr).
-
The naturally occurring radioisotope $^{32}$Si represents a potentially
limiting background in future dark matter direct-detection experiments. We
investigate sources of $^{32}$Si and the vectors by which it comes to reside in
silicon crystals used for fabrication of radiation detectors. We infer that the
$^{32}$Si concentration in commercial single-crystal silicon is likely
variable, dependent upon the specific geologic and hydrologic history of the
source (or sources) of silicon "ore" and the details of the silicon-refinement
process. The silicon production industry is large, highly segmented by refining
step, and multifaceted in terms of final product type, from which we conclude
that production of $^{32}$Si-mitigated crystals requires both targeted silicon
material selection and a dedicated refinement-through-crystal-production
process. We review options for source material selection, including quartz from
an underground source and silicon isotopically reduced in $^{32}$Si. To
quantitatively evaluate the $^{32}$Si content in silicon metal and precursor
materials, we propose analytic methods employing chemical processing and
radiometric measurements. Ultimately, it appears feasible to produce silicon
detectors with low levels of $^{32}$Si, though significant assay method
development is required to validate this claim and thereby enable a quality
assurance program during an actual controlled silicon-detector production
cycle.
-
A new design for the anode of a time projection chamber, consisting of a
charge-detecting "tile", is investigated for use in large scale liquid xenon
detectors. The tile is produced by depositing 60 orthogonal metal
charge-collecting strips, 3~mm wide, on a 10~\si{\cm} $\times$ 10~\si{\cm}
fused-silica wafer. These charge tiles may be employed by large detectors, such
as the proposed tonne-scale nEXO experiment to search for neutrinoless
double-beta decay. Modular by design, an array of tiles can cover a sizable
area. The width of each strip is small compared to the size of the tile, so a
Frisch grid is not required. A grid-less, tiled anode design is beneficial for
an experiment such as nEXO, where a wire tensioning support structure and
Frisch grid might contribute radioactive backgrounds and would have to be
designed to accommodate cycling to cryogenic temperatures. The segmented anode
also reduces some degeneracies in signal reconstruction that arise in
large-area crossed-wire time projection chambers. A prototype tile was tested
in a cell containing liquid xenon. Very good agreement is achieved between the
measured ionization spectrum of a $^{207}$Bi source and simulations that
include the microphysics of recombination in xenon and a detailed modeling of
the electrostatic field of the detector. An energy resolution $\sigma/E$=5.5\%
is observed at 570~\si{keV}, comparable to the best intrinsic ionization-only
resolution reported in literature for liquid xenon at 936~V/\si{cm}.
-
The SuperCDMS experiment is designed to directly detect weakly interacting
massive particles (WIMPs) that may constitute the dark matter in our Galaxy.
During its operation at the Soudan Underground Laboratory, germanium detectors
were run in the CDMSlite mode to gather data sets with sensitivity specifically
for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias
voltage is applied to amplify the phonon signals produced by drifting charges.
This paper presents studies of the experimental noise and its effect on the
achievable energy threshold, which is demonstrated to be as low as 56
eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing
configuration is described in detail, with analysis corrections for voltage
variations to the level of a few percent. Detailed studies of the
electric-field geometry, and the resulting successful development of a fiducial
parameter, eliminate poorly measured events, yielding an energy resolution
ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at
${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical
uncertainties relevant to the WIMP-search limits, specifically examining how
they are affected by variations in the most probable WIMP velocity and the
Galactic escape velocity. These variations become more important for WIMP
masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass
WIMP-nucleon interactions are derived, with new parameter space excluded for
WIMP masses $\lesssim$3 GeV/$c^2$
-
We report the result of a blinded search for Weakly Interacting Massive
Particles (WIMPs) using the majority of the SuperCDMS Soudan dataset. With an
exposure of 1690 kg days, a single candidate event is observed, consistent with
expected backgrounds. This analysis (combined with previous Ge results) sets an
upper limit on the spin-independent WIMP--nucleon cross section of $1.4 \times
10^{-44}$ ($1.0 \times 10^{-44}$) cm$^2$ at 46 GeV/$c^2$. These results set the
strongest limits for WIMP--germanium-nucleus interactions for masses $>$12
GeV/$c^2$.
-
The coherent elastic scattering of neutrinos off nuclei has eluded detection
for four decades, even though its predicted cross-section is the largest by far
of all low-energy neutrino couplings. This mode of interaction provides new
opportunities to study neutrino properties, and leads to a miniaturization of
detector size, with potential technological applications. We observe this
process at a 6.7-sigma confidence level, using a low-background, 14.6-kg
CsI[Na] scintillator exposed to the neutrino emissions from the Spallation
Neutron Source (SNS) at Oak Ridge National Laboratory. Characteristic
signatures in energy and time, predicted by the Standard Model for this
process, are observed in high signal-to-background conditions. Improved
constraints on non-standard neutrino interactions with quarks are derived from
this initial dataset.
-
The MAJORANA Collaboration is searching for the neutrinoless double-beta
decay of the nucleus $^{76}$Ge. The MAJORANA DEMONSTRATOR is an array of
germanium detectors deployed with the aim of implementing background reduction
techniques suitable for a 1-tonne $^{76}$Ge-based search. The ultra
low-background conditions require regular calibrations to verify proper
function of the detectors. Radioactive line sources can be deployed around the
cryostats containing the detectors for regular energy calibrations. When
measuring in low-background mode, these line sources have to be stored outside
the shielding so they do not contribute to the background. The deployment and
the retraction of the source are designed to be controlled by the data
acquisition system and do not require any direct human interaction. In this
paper, we detail the design requirements and implementation of the calibration
apparatus, which provides the event rates needed to define the pulse-shape cuts
and energy calibration used in the final analysis as well as data that can be
compared to simulations.
-
A search for Pauli-exclusion-principle-violating K-alpha electron transitions
was performed using 89.5 kg-d of data collected with a p-type point contact
high-purity germanium detector operated at the Kimballton Underground Research
Facility. A lower limit on the transition lifetime of 5.8x10^30 seconds at 90%
C.L. was set by looking for a peak at 10.6 keV resulting from the x-ray and
Auger electrons present following the transition. A similar analysis was done
to look for the decay of atomic K-shell electrons into neutrinos, resulting in
a lower limit of 6.8x10^30 seconds at 90 C.L. It is estimated that the MAJORANA
DEMONSTRATOR, a 44 kg array of p-type point contact detectors that will search
for the neutrinoless double-beta decay of 76-Ge, could improve upon these
exclusion limits by an order of magnitude after three years of operation.
-
The Majorana Demonstrator searches for neutrinoless double-beta decay of
$^{76}$Ge using arrays of high-purity germanium detectors. If observed, this
process would demonstrate that lepton number is not a conserved quantity in
nature, with implications for grand-unification and for explaining the
predominance of matter over antimatter in the universe. A problematic
background in such large granular detector arrays is posed by alpha particles.
In the Majorana Demonstrator, events have been observed that are consistent
with energy- degraded alphas originating on the passivated surface, leading to
a potential background contribution in the region-of-interest for neutrinoless
double-beta decay. However, it is also observed that when energy deposition
occurs very close to the passivated surface, charges drift through the bulk
onto that surface, and then drift along it with greatly reduced mobility. This
leads to both a reduced prompt signal and a measurable change in slope of the
tail of a recorded pulse. In this contribution we discuss the characteristics
of these events and the development of a filter that can identify the
occurrence of this delayed charge recovery, allowing for the efficient
rejection of passivated surface alpha events in analysis.
-
Neutrinoless double-beta decay searches seek to determine the nature of
neutrinos, the existence of a lepton violating process, and the effective
Majorana neutrino mass. The {\sc Majorana} Collaboration is assembling an array
of high purity Ge detectors to search for neutrinoless double-beta decay in
$^{76}$Ge. The {\sc Majorana Demonstrator} is composed of 44.8~kg (29.7 kg
enriched in $^{76}$Ge) of Ge detectors in total, split between two modules
contained in a low background shield at the Sanford Underground Research
Facility in Lead, South Dakota. The initial goals of the {\sc Demonstrator} are
to establish the required background and scalability of a Ge-based,
next-generation, tonne-scale experiment. Following a commissioning run that
began in 2015, the first detector module started physics data production in
early 2016. We will discuss initial results of the Module 1 commissioning and
first physics run, as well as the status and potential physics reach of the
full {\sc Majorana Demonstrator} experiment. The collaboration plans to
complete the assembly of the second detector module by mid-2016 to begin full
data production with the entire array.
-
The MAJORANA Collaboration is constructing a system containing 44 kg of
high-purity Ge (HPGe) detectors to demonstrate the feasibility and potential of
a future tonne-scale experiment capable of probing the neutrino mass scale to
~15 meV. To realize this, a major goal of the MAJORANA DEMONSTRATOR is to
demonstrate a path forward to achieving a background rate at or below 1
count/(ROI-t-y) in the 4 keV region of interest (ROI) around the Q-value at
2039 keV. This goal is pursued through a combination of a significant reduction
of radioactive impurities in construction materials and analytical methods for
background rejection, for example using powerful pulse shape analysis
techniques profiting from the p-type point contact HPGe detectors technology.
The effectiveness of these methods is assessed using simulations of the
different background components whose purity levels are constrained from
radioassay measurements. Preliminary background results obtained during the
engineering runs of the Demonstrator are presented.
-
We report the first measurement of the total MUON flux underground at the
Davis Campus of the Sanford Underground Research Facility at the 4850 ft level.
Measurements were done with the Majorana Demonstrator veto system arranged in
two different configurations. The measured total flux is (5.31+/-0.17) x 10^-9
muons/s/cm^2.
-
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an
ultra-low background, modular, HPGe detector array with a mass of 44.8-kg (29.7
kg enriched >88% in Ge-76) to search for neutrinoless double beta decay in
Ge-76. The next generation of tonnescale Ge-based neutrinoless double beta
decay searches will probe the neutrino mass scale in the inverted-hierarchy
region. The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward
to achieve a background rate at or below 1 count/tonne/year in the 4 keV region
of interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a
modular implementation to be easily scalable to the next generation experiment.
First data taken with the DEMONSTRATOR are introduced here.
-
The MAJORANA collaboration is constructing the MAJORANA DEMONSTATOR at the
Sanford Underground Research Facility at the Homestake gold mine, in Lead, SD.
The apparatus will use Ge detectors, enriched in isotope \nuc{76}{Ge}, to
demonstrate the feasibility of a large-scale Ge detector experiment to search
for neutrinoless double beta decay. The long half-life of this postulated
process requires that the apparatus be extremely low in radioactive isotopes
whose decays may produce backgrounds to the search. The radioassay program
conducted by the collaboration to ensure that the materials comprising the
apparatus are sufficiently pure is described. The resulting measurements of the
radioactive-isotope contamination for a number of materials studied for use in
the detector are reported.
-
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an
ultra-low background, 44-kg modular high-purity Ge (HPGe) detector array to
search for neutrinoless double-beta decay in Ge-76. The phenomenon of surface
micro-discharge induced by high-voltage has been studied in the context of the
MAJORANA Demonstrator. This effect can damage the front-end electronics or
mimic detector signals. To ensure the correct performance, every high-voltage
cable and feedthrough must be capable of supplying HPGe detector operating
voltages as high as 5 kV without exhibiting discharge. R&D measurements were
carried out to understand the testing system and determine the optimum design
configuration of the high-voltage path, including different improvements of the
cable layout and feedthrough flange model selection. Every cable and
feedthrough to be used at the MAJORANA Demonstrator was characterized and the
micro-discharge effects during the MAJORANA Demonstrator commissioning phase
were studied. A stable configuration has been achieved, and the cables and
connectors can supply HPGe detector operating voltages without exhibiting
discharge.
-
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an
ultra-low background, modular, HPGe detector array with a mass of 44-kg (29 kg
76Ge and 15 kg natGe) to search for neutrinoless double beta decay in Ge-76.
The next generation of tonne-scale Ge-based neutrinoless double beta decay
searches will probe the neutrino mass scale in the inverted-hierarchy region.
The MAJORANA DEMONSTRATOR is envisioned to demonstrate a path forward to
achieve a background rate at or below 1 count/tonne/year in the 4 keV region of
interest around the Q-value of 2039 keV. The MAJORANA DEMONSTRATOR follows a
modular implementation to be easily scalable to the next generation experiment.
First, the prototype module was assembled; it has been continuously taking data
from July 2014 to June 2015. Second, Module 1 with more than half of the total
enriched detectors and some natural detectors has been assembled and it is
being commissioned. Finally, the assembly of Module 2, which will complete
MAJORANA DEMONSTRATOR, is already in progress.
-
The MAJORANA Collaboration will seek neutrinoless double beta decay (0nbb) in
76Ge using isotopically enriched p-type point contact (PPC) high purity
Germanium (HPGe) detectors. A tonne-scale array of HPGe detectors would require
background levels below 1 count/ROI-tonne-year in the 4 keV region of interest
(ROI) around the 2039 keV Q-value of the decay. In order to demonstrate the
feasibility of such an experiment, the MAJORANA DEMONSTRATOR, a 40 kg HPGe
detector array, is being constructed with a background goal of <3
counts/ROI-tonne-year, which is expected to scale down to <1
count/ROI-tonne-year for a tonne-scale experiment. The signal readout
electronics, which must be placed in close proximity to the detectors, present
a challenge toward reaching this background goal. This talk will discuss the
materials and design used to construct signal readout electronics with low
enough backgrounds for the MAJORANA DEMONSTRATOR.
-
The MAJORANA Collaboration is constructing the MAJORANA DEMONSTRATOR, an
ultra-low background, 40-kg modular HPGe detector array to search for
neutrinoless double beta decay in 76Ge. In view of the next generation of
tonne-scale Ge-based 0nbb-decay searches that will probe the neutrino mass
scale in the inverted-hierarchy region, a major goal of the MAJORANA
DEMONSTRATOR is to demonstrate a path forward to achieving a background rate at
or below 1 count/tonne/year in the 4 keV region of interest around the Q-value
at 2039 keV. The background rejection techniques to be applied to the data
include cuts based on data reduction, pulse shape analysis, event coincidences,
and time correlations. The Point Contact design of the DEMONSTRATOR 0s
germanium detectors allows for significant reduction of gamma background.
-
CoGeNT has taken data for over 3 years, with 1136 live days of data
accumulated as of April 23, 2013. We report on the results of a maximum
likelihood analysis to extract any possible dark matter signal present in the
collected data. The maximum likelihood signal extraction uses 2-dimensional
probability density functions (PDFs) to characterize the anticipated variations
in dark matter interaction rates for given observable nuclear recoil energies
during differing periods of the Earth's annual orbit around the Sun. Cosmogenic
and primordial radioactivity backgrounds are characterized by their energy
signatures and in some cases decay half-lives. A third parameterizing variable
-- pulse rise-time -- is added to the likelihood analysis to characterize slow
rising pulses described in prior analyses. The contribution to each event
category is analyzed for various dark matter signal hypotheses including a dark
matter standard halo model and a case with free oscillation parameters (i.e.,
amplitude, period, and phase). The best-fit dark matter signal is in close
proximity to previously reported results. We find that the significance of the
extracted dark matter signal remains well below evidentiary at 1.7 $\sigma$.
-
The MAJORANA Collaboration is constructing the MAJORANA Demonstrator, an
ultra-low background, 40-kg modular high purity Ge detector array to search for
neutrinoless double-beta decay in Ge. In view of the next generation of
tonne-scale Ge-based neutrinoless double-beta decay searches that will probe
the neutrino mass scale in the inverted-hierarchy region, a major goal of the
Demonstrator is to demonstrate a path forward to achieving a background rate at
or below 1 count/tonne/year in the 4 keV region of interest around the Q-value
at 2039 keV. The current status of the Demonstrator is discussed, as are plans
for its completion.
-
We study the possibility of using CsI[Na] scintillators as an advantageous
target for the detection of coherent elastic neutrino-nucleus scattering
(CENNS), using the neutrino emissions from the SNS spallation source at Oak
Ridge National Laboratory. The response of this material to low-energy nuclear
recoils like those expected from this process is characterized. Backgrounds are
studied using a 2 kg low-background prototype crystal in a dedicated radiation
shield. The conclusion is that a planned 14 kg detector should measure
approximately 550 CENNS events per year above a demonstrated $\sim7$ keVnr
low-energy threshold, with a signal-to-background ratio sufficient for a first
measurement of the CENNS cross-section. The cross-section for the
$^{208}$Pb($\nu_{e},e^{-}$)$^{208}$Bi reaction, of interest for future
supernova neutrino detection, can be simultaneously obtained.
-
The MAJORANA DEMONSTRATOR is an array of natural and enriched high purity
germanium detectors that will search for the neutrinoless double-beta decay of
76-Ge and perform a search for weakly interacting massive particles (WIMPs)
with masses below 10 GeV. As part of the MAJORANA research and development
efforts, we have deployed a modified, low-background broad energy germanium
detector at the Kimballton Underground Research Facility. With its sub-keV
energy threshold, this detector is sensitive to potential non-Standard Model
physics, including interactions with WIMPs. We discuss the backgrounds present
in the WIMP region of interest and explore the impact of slow surface event
contamination when searching for a WIMP signal.