• The accuracy of dielectronic recombination (DR) data for astrophysics related ions plays a key role in astrophysical plasma modeling. The measurement of the absolute DR rate coefficient of Fe17+ ions was performed at the main cooler storage ring at Institute of Modern Physics, Lanzhou, China. The experimental electron-ion collision energy range covers first Rydberg series up to n = 24 for the DR resonances associated with the 2P1/2--2P3/2 dn = 0 core excitations. A theoretical calculation was performed by using FAC code and compared with the measured DR rate coefficient. Overall reasonable agreement was found between the experimental results and calculations. Moreover, plasma rate coefficient was deduced from the experimental DR rate coefficient and compared with the available results from the literature. At the low energy range significant discrepancies were found therein and the measured resonances challenged state-of-the-art theory at the low collision energies.
  • The RIBLL2 in-flight separator at IMP, the secondary beam line between two storage rings at the \blue{\uwave{Heavy Ion Research Facility in Lanzhou (HIRFL-CSR)}}, has been commissioned to study the rare-isotope beam (RIB) physics at around 300 MeV/nucleon for the first time, in combination of the external target facility (ETF). The unambiguous particle identification in mass and charge states for $^{18}$O and $^{40}$Ar fragments has been achieved in recent experiments. A full realization of RIBLL2 will open many potentials to address important RIB physics problems at around 300 MeV/nucleon.
  • Laser cooling of relativistic heavy ion beams of Li-like C$^{3+}$ and O$^{4+}$ is being in preparation at the experimental Cooler Storage Ring (CSRe). Recently, a preparatory experiment to test important prerequisites for laser cooling of relativistic $^{12}$C$^{3+}$ ion beams using a pulsed laser system has been performed at the CSRe. Unfortunately, the interaction between the ions and the pulsed laser cannot be detected. In order to study the laser cooling process and find the optimized parameters for future laser cooling experiment, a multi-particle tracking method was developed to simulate the detailed longitudinal dynamics of laser-cooled ion beams at the CSRe. The simulations of laser cooling of the $^{12}$C$^{3+}$ ion beams by scanning the frequency of RF-buncher or continuous wave (CW) laser wavelength were performed. The simulation results indicated that a large momentum spread ion beams could be laser-cooled by the combination of only one CW laser and the RF-buncher and shown the requirements of a successful laser cooling experiment. The optimized parameters for scanning the RF-buncher frequency or laser frequency were obtained. Furthermore, the heating effects were estimated for laser cooling at the CSRe. The Schottky noise spectra of longitudinally modulated and laser-cooled ion beams was simulated to fully explain and anticipate the experimental results. The combination of Schottky spectra from the highly sensitive resonant Schottky pick-up and the simulation methods developed in this paper will be helpful to investigate the longitudinal dynamics of RF-bunched and ultra-cold ion beams in the upcoming laser cooling experiments at the CSRe.
  • A new accelerator complex, HIAF (the High Intensity Heavy Ion Accelerator Facility), has been approved in China. It is designed to provide intense primary and radioactive ion beams for research in high energy density physics, nuclear physics, atomic physics as well as other applications. In order to achieve a high intensity of up to 5e11 ppp 238U34+, the Compression Ring (CRing) needs to stack more than 5 bunches transferred from the Booster Ring (BRing). However, the normal bucket to bucket injection scheme can only achieve an intensity gain of 2, so an injection method, fixed barrier bucket (BB) supported by electron cooling, is proposed. To suppress the severe space charge effect during the stacking process, off-alignment is adopted in the cooler to control the transverse emittance. In this paper, simulation and optimization with the BETACOOL program are presented.
  • In this paper, we present direct mass measurements of neutron-rich $^{86}$Kr projectile fragments conducted at the HIRFL-CSR facility in Lanzhou by employing the Isochronous Mass Spectrometry (IMS) method. The new mass excesses of $^{52-54}$Sc nuclides are determined to be -40492(82), -38928(114), -34654(540) keV, which show a significant increase of binding energy compared to the reported ones in the Atomic Mass Evaluation 2012 (AME12). In particular, $^{53}$Sc and $^{54}$Sc are more bound by 0.8 MeV and 1.0 MeV, respectively. The behavior of the two neutron separation energy with neutron numbers indicates a strong sub-shell closure at neutron number $N$ = 32 in Sc isotopes.
  • The correction of closed orbit has great influence on the operation of synchrotron. The design of correction system is one significant component of lattice design. It is suggested to set BPMs at the peaks of betatron oscillation. The correctors need to be located at the positions where \b{eta} function is large or the sources of large errors. In the simulation of the closed orbit correction of HIMM synchrotron, one important reason affecting the result of horizontal correction is the longitudinal alignment error of dipole magnet. It is advisable to decrease this kind of alignment error while the deflection angle of dipole magnet is large.
  • Proton radiography is used for advanced hydrotesting as a new type radiography technology due to its powerful penetration capability and high detection efficiency. A new proton radiography terminal will be developed to radiograph static samples at Institute of Modern Physics of Chinese Academy of Science (IMP-CAS). The proton beam with the maximum energy of 2.6 GeV will be produced by Heavy Ion Research Facility in Lanzhou-Cooling Storage Ring (HIRFL-CSR). The proton radiography terminal consists of the matching magnetic lens and the Zumbro lens system. In this paper, the design scheme and all optic parameters of this beam terminal for 2.6GeV proton energy are presented by simulating the beam optics using WINAGILE code. My-BOC code is used to test the particle tracking of proton radiography beam line. Geant4 code and G4beamline code are used for simulating the proton radiography system. The results show that the transmission efficiency of proton without target is 100%, and the effect of secondary particles can be neglected. In order to test this proton radiography system, the proton images for an aluminum plate sample with two rectangular orifices and a step brass plate sample are respectively simulated using Geant4 code. The results show that the best spatial resolution is about 36{\mu}m, and the differences of the thickness is not greater than 10%.
  • In order to investigate the longitudinal beam dynamics during the adiabatic capture and acceleration processes of the CRing in HIAF project, a simulation of both processes above is carried out with $U^{34+}$ ions. The ions will be captured into a bucket adiabatically and accelerated from 800 MeV/u to 1130 MeV/u . Simulation of these processes by tracking appropriate distributions with the longitudinal beam dynamics code ESME has been used to find optimum parameters such as RF phase, RF voltage and RF frequency etc. An enhanced capture and acceleration efficiency can be gotten from the simulation results, with the optimized RF voltage and RF phase program.