PandaX is a large upgradable liquid-xenon detector system that can be used
for both direct dark-matter detection and $^{136}$Xe double-beta decay search.
It is located in the Jinping Deep-Underground Laboratory in Sichuan, China. The
detector operates in dual-phase mode, allowing detection of both prompt
scintillation, and ionization charge through proportional scintillation. The
central time projection chamber will be staged, with the first stage
accommodating a target mass of about 120\,kg. In stage II, the target mass will
be increased to about 0.5\,ton. In the final stage, the detector can be
upgraded to a multi-ton target mass. In this paper a detailed description of
the stage-I detector design and performance results established during the
commissioning phase is presented.
-
The XENON100 dark matter experiment uses liquid xenon (LXe) in a time
projection chamber (TPC) to search for Xe nuclear recoils resulting from the
scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this
paper we present a detailed description of the detector design and present
performance results, as established during the commissioning phase and during
the first science runs.
The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe
veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating
inside the liquid or in Xe gas. The LXe target and veto are contained in a
low-radioactivity stainless steel vessel, embedded in a passive radiation
shield. The experiment is installed underground at the Laboratori Nazionali del
Gran Sasso (LNGS), Italy and has recently published results from a 100
live-days dark matter search. The ultimate design goal of XENON100 is to
achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of
\sigma = 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.
-
Liquid-xenon based particle detectors have been dramatically growing in size
during the last years, and are now exceeding the one-ton scale. The required
high xenon purity is usually achieved by continuous recirculation of xenon gas
through a high-temperature getter. This challenges the traditional way of
cooling these large detectors, since in a thermally well insulated detector,
most of the cooling power is spent to compensate losses from recirculation. The
phase change during recondensing requires five times more cooling power than
cooling the gas from ambient temperature to -100C (173 K). Thus, to reduce the
cooling power requirements for large detectors, we propose to use the heat from
the purified incoming gas to evaporate the outgoing xenon gas, by means of a
heat exchanger. Generally, a heat exchanger would appear to be only of very
limited use, since evaporation and liquefaction occur at zero temperature
difference. However, the use of a recirculation pump reduces the pressure of
the extracted liquid, forces it to evaporate, and thus cools it down. We show
that this temperature difference can be used for an efficient heat exchange
process. We investigate the use of a commercial parallel plate heat exchanger
with a small liquid xenon detector. Although we expected to be limited by the
available cooling power to flow rates of about 2 SLPM, rates in excess of 12
SLPM can easily be sustained, limited only by the pump speed and the impedance
of the flow loop. The heat exchanger operates with an efficiency of (96.8 +/-
0.5)%. This opens the possibility for fast xenon gas recirculation in
large-scale experiments, while minimizing thermal losses.
-
Liquid xenon is an important detection medium in direct dark matter
experiments, which search for low-energy nuclear recoils produced by the
elastic scattering of WIMPs with quarks. The two existing measurements of the
relative scintillation efficiency of nuclear recoils below 20 keV lead to
inconsistent extrapolations at lower energies. This results in a different
energy scale and thus sensitivity reach of liquid xenon dark matter detectors.
We report a new measurement of the relative scintillation efficiency below 10
keV performed with a liquid xenon scintillation detector, optimized for maximum
light collection. Greater than 95% of the interior surface of this detector was
instrumented with photomultiplier tubes, giving a scintillation yield of 19.6
photoelectrons/keV electron equivalent for 122 keV gamma rays. We find that the
relative scintillation efficiency for nuclear recoils of 5 keV is 0.14, staying
constant around this value up to 10 keV. For higher energy recoils we measure a
value around 20%, consistent with previously reported data. In light of this
new measurement, the XENON10 experiment's results on spin-independent
WIMP-nucleon cross section, which were calculated assuming a constant 0.19
relative scintillation efficiency, change from $8.8\times10^{-44}$ cm$^2$ to
$9.9\times10^{-44}$ cm$^2$ for WIMPs of mass 100 GeV/c$^2$, and from
$4.4\times10^{-44}$ cm$^2$ to $5.6\times10^{-44}$ cm$^2$ for WIMPs of mass 30
GeV/c$^2$.
-
The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is the first
realization of a liquid xenon time projection chamber for Compton imaging of
MeV gamma-ray sources in astrophysics. By measuring the energy deposit and the
three spatial coordinates of individual gamma-ray scattering points, the
location of the source in the sky is inferred with Compton kinematics
reconstruction. The angular resolution is determined by the detector's energy
and spatial resolutions, as well as by the separation in space between the
first and second scattering. The imaging response of LXeGRIT was established
with gamma-rays from radioactive sources, during calibration and integration at
the Columbia Astrophysics Laboratory, prior to the 2000 balloon flight mission.
In this paper we describe in detail the various steps involved in imaging
sources with LXeGRIT and present experimental results on angular resolution and
other parameters which characterize its performance as a Compton telescope.
-
Liquid Xenon (LXe) is expected to be an excellent target and detector medium
to search for dark matter in the form of Weakly Interacting Massive Particles
(WIMPs). Knowledge of LXe ionization and scintillation response to low energy
nuclear recoils expected from the scattering of WIMPs by Xe nuclei is important
for determining the sensitivity of LXe direct detection experiments. Here we
report on new measurements of the scintillation yield of Xe recoils with
kinetic energy as low as 10 keV. The dependence of the scintillation yield on
applied electric field was also measured in the range of 0 to 4 kV/cm. Results
are in good agreement with recent theoretical predictions that take into
account the effect of biexcitonic collisions in addition to the nuclear
quenching effect.
-
Scintillation light produced in liquid xenon (LXe) by alpha particles,
electrons and gamma-rays was detected with a large area avalanche photodiode
(LAAPD) immersed in the liquid. The alpha scintillation yield was measured as a
function of applied electric field. We estimate the quantum efficiency of the
LAAPD to be 45%. The best energy resolution from the light measurement at zero
electric field is 7.5%(sigma) for 976 keV internal conversion electrons from
Bi-207 and 2.6%(sigma) for 5.5 MeV alpha particles from Am-241. The detector
used for these measurements was also operated as a gridded ionization chamber
to measure the charge yield. We confirm that using a LAAPD in LXe does not
introduce impurities which inhibit the drifting of free electrons.