The single-phase liquid argon time projection chamber (LArTPC) provides a
large amount of detailed information in the form of fine-grained drifted
ionization charge from particle traces. To fully utilize this information, the
deposited charge must be accurately extracted from the raw digitized waveforms
via a robust signal processing chain. Enabled by the ultra-low noise levels
associated with cryogenic electronics in the MicroBooNE detector, the precise
extraction of ionization charge from the induction wire planes in a
single-phase LArTPC is qualitatively demonstrated on MicroBooNE data with event
display images, and quantitatively demonstrated via waveform-level and
track-level metrics. Improved performance of induction plane calorimetry is
demonstrated through the agreement of extracted ionization charge measurements
across different wire planes for various event topologies. In addition to the
comprehensive waveform-level comparison of data and simulation, a calibration
of the cryogenic electronics response is presented and solutions to various
MicroBooNE-specific TPC issues are discussed. This work presents an important
improvement in LArTPC signal processing, the foundation of reconstruction and
therefore physics analyses in MicroBooNE.
-
We describe the concept and procedure of drifted-charge extraction developed
in the MicroBooNE experiment, a single-phase liquid argon time projection
chamber (LArTPC). This technique converts the raw digitized TPC waveform to the
number of ionization electrons passing through a wire plane at a given time. A
robust recovery of the number of ionization electrons from both induction and
collection anode wire planes will augment the 3D reconstruction, and is
particularly important for tomographic reconstruction algorithms. A number of
building blocks of the overall procedure are described. The performance of the
signal processing is quantitatively evaluated by comparing extracted charge
with the true charge through a detailed TPC detector simulation taking into
account position-dependent induced current inside a single wire region and
across multiple wires. Some areas for further improvement of the performance of
the charge extraction procedure are also discussed.
-
This paper describes the design and construction of the MicroBooNE liquid
argon time projection chamber and associated systems. MicroBooNE is the first
phase of the Short Baseline Neutrino program, located at Fermilab, and will
utilize the capabilities of liquid argon detectors to examine a rich assortment
of physics topics. In this document details of design specifications, assembly
procedures, and acceptance tests are reported.