The CUORE experiment, a ton-scale cryogenic bolometer array, recently began
operation at the Laboratori Nazionali del Gran Sasso in Italy. The array
represents a significant advancement in this technology, and in this work we
apply it for the first time to a high-sensitivity search for a
lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay.
Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an
effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the
region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we
find no evidence for neutrinoless double-beta decay. The median statistical
sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic
uncertainties, we place a lower limit on the decay half-life of
$T^{0\nu}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining
this result with those of two earlier experiments, Cuoricino and CUORE-0, we
find $T^{0\nu}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is
the most stringent limit to date on this decay. Interpreting this result as a
limit on the effective Majorana neutrino mass, we find $m_{\beta\beta}<(110 -
520)$ meV, where the range reflects the nuclear matrix element estimates
employed.
-
The CUPID-0 detector hosted at the Laboratori Nazionali del Gran Sasso,
Italy, is the first large array of enriched scintillating cryogenic detectors
for the investigation of $^{82}$Se neutrinoless double-beta decay
(0$\nu\beta\beta$). CUPID-0 aims at measuring a background index in the region
of interest (RoI) for 0$\nu\beta\beta$ at the level of 10$^{-3}$ c/keV/kg/y,
the lowest value ever measured using cryogenic detectors. This result can be
achieved by a state of the art technology for background suppression and
thorough protocols and procedures for detector preparation and construction. In
this paper, the different phases of the detector design and construction will
be presented, from the material selection (for the absorber production) to the
new and innovative detector structure. The successful construction of the
detector lead to promising detector performance which are here preliminarily
discussed
-
We report the result of the search for neutrinoless double beta decay of
$^{82}$Se obtained with CUPID-0, the first large array of scintillating
Zn$^{82}$Se cryogenic calorimeters implementing particle identification. We
observe no signal in a 1.83 kg$\cdot$yr $^{82}$Se exposure and we set the most
stringent lower limit on the \onu $^{82}$Se half-life T$^{0\nu}_{1/2}>$
2.4$\cdot \mathrm{10}^{24}$ yr (90\% C.I.), which corresponds to an effective
Majorana neutrino mass m$_{\beta\beta} <$ (376-770) meV depending on the
nuclear matrix element calculations. The heat-light readout provides a powerful
tool for the rejection of \al\ particles and allows to suppress the background
in the region of interest down to (3.6$^{+1.9}_{-1.4}$)$\cdot$10$^{-3}$\ckky,
an unprecedented level for this technique.
-
TeO2 bolometers have been used for many years to search for neutrinoless
double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently
published the most sensitive limit on the half-life, $T_{1/2}^{0\nu} > 1.5
\times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on
the effective Majorana mass of the neutrino. While it makes CUORE a
world-leading experiment looking for neutrinoless double beta decay, it is not
the only study that CUORE will contribute to in the field of nuclear and
particle physics. As already done over the years with many small-scale
experiments, CUORE will investigate both rare decays (such as the two-neutrino
double beta decay of 130-Te and the hypothesized electron capture in 123-Te),
and rare processes (e.g., dark matter and axion interactions). This paper
describes some of the achievements of past experiments that used TeO2
bolometers, and perspectives for CUORE.
-
We have performed a search for neutrinoless $\beta^{+}\hspace{-0.2em}EC$
decay of $^{120}$Te using the final CUORE-0 data release. We describe a new
analysis method for the simultaneous fit of signatures with different event
topology, and of data subsets with different signal efficiency, obtaining a
limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$
CI. Combining this with results from Cuoricino, a predecessor experiment, we
obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$
yr at $90\%$ CI.
-
This paper reports on the development of a technology involving
$^{100}$Mo-enriched scintillating bolometers, compatible with the goals of
CUPID, a proposed next-generation bolometric experiment to search for
neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality,
radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been
produced and used to develop high performance single detector modules based on
0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of
the lithium molybdate detectors near the $Q$-value of the double-beta
transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the
$\alpha$-induced dominant background above 2.6~MeV is better than 8$\sigma$.
Less than 10~$\mu$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in
the crystals is ensured by boule recrystallization. The potential of
$^{100}$Mo-enriched scintillating bolometers to perform high sensitivity
double-beta decay searches has been demonstrated with only 10~kg$\times$d
exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been
measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$
0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and
detector technologies favor lithium molybdate, which has been selected for the
ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of
$^{100}$Mo.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to
search for neutrinoless double beta decay of 130Te with an array of 988 TeO2
bolometers operating at temperatures around 10 mK. The experiment is currently
being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The
goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay
half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main
issue to be addressed to accomplish this aim is the rate of background events
in the region of interest, which must not be higher than
10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation,
based on results from a campaign of material screening, radioassays, and
bolometric measurements, to evaluate the expected background. This was used
over the years to guide the construction strategies of the experiment and we
use it here to project a background model for CUORE. In this paper we report
the results of our study and our expectations for the background rate in the
energy region where the peak signature of neutrinoless double beta decay of
130Te is expected.
-
CUORE is a tonne-scale cryogenic detector operating at the Laboratori
Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to
search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable
to search for low energy rare events such as solar axions or WIMP scattering,
thanks to its ultra-low background and large target mass. However, to conduct
such sensitive searches requires improving the energy threshold to 10 keV. In
this paper, we describe the analysis techniques developed for the low energy
analysis of CUORE-like detectors, using the data acquired from November 2013 to
March 2015 by CUORE-0, a single-tower prototype designed to validate the
assembly procedure and new cleaning techniques of CUORE. We explain the energy
threshold optimization, continuous monitoring of the trigger efficiency, data
and event selection, and energy calibration at low energies in detail. We also
present the low energy background spectrum of CUORE-0 below 60keV. Finally, we
report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0
energy threshold and background, as well as an estimate of the uncertainty on
the nuclear quenching factor from nuclear recoils in CUORE-0.
-
We report a study of the CUORE sensitivity to neutrinoless double beta
($0\nu\beta\beta$) decay. We used a Bayesian analysis based on a toy Monte
Carlo (MC) approach to extract the exclusion sensitivity to the
$0\nu\beta\beta$ decay half-life ($T_{1/2}^{0\nu}$) at $90\%$ credibility
interval (CI) -- i.e. the interval containing the true value of
$T_{1/2}^{0\nu}$ with $90\%$ probability -- and the $3 \sigma$ discovery
sensitivity. We consider various background levels and energy resolutions, and
describe the influence of the data division in subsets with different
background levels. If the background level and the energy resolution meet the
expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of
$2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of
live time. Under the same conditions, the discovery sensitivity after $3$
months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr,
respectively.
-
Recently there is a flourishing and notable interest in the crystalline
scintillator material sodium iodide (NaI) as target for direct dark matter
searches. This is mainly driven by the long-reigning contradicting situation in
the dark matter sector: the positive evidence for the detection of a dark
matter modulation signal claimed by the DAMA/LIBRA collaboration is (under
so-called standard assumptions) inconsistent with the null-results reported by
most of the other direct dark matter experiments. We present the results of a
first prototype detector using a new experimental approach in comparison to
conventional single-channel NaI scintillation light detectors: a NaI crystal
operated as a scintillating calorimeter at milli-Kelvin temperatures
simultaneously providing a phonon (heat) plus scintillation light signal and
particle discrimination on an event-by-event basis. We evaluate energy
resolution, energy threshold and further performance parameters of this
prototype detector developed within the COSINUS R&D project.
-
In recent years the scintillation mechanism of inorganic crystals has been
extensively investigated in different studies. The main issues are the
non-proportionality mechanism of the light response versus energy and its
connection with the shaping time used for the scintillation signals. In this
study the Compton coincidence technique has been used to measure the relative
non-proportionality of three crystals: CdWO$_{4}$, BGO, and NaI(Tl). To test
the non-proportionality dependence on shaping time, the preamplified
scintillator pulses have been digitized and shaped with a digital trapezoidal
filter. Since no analogic shaping occurs the majority of the scintillation
components are digitized, thus avoiding major information losses. The obtained
results suggest the existence of a correlation between the time constant of the
scintillation emission and light yield.
-
We report on the measurement of the two-neutrino double beta decay half-life
of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of
TeO$_2$, the half-life is determined to be $T_{1/2}^{2\nu}$ = [8.2 $\pm$ 0.2
(stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a
detailed reconstruction of the sources responsible for the CUORE-0 counting
rate, with a specific study of those contributing to the $^{130}$Te
neutrinoless double beta decay region of interest.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton
scale bolometric experiment devoted to the search of the neutrinoless
double-beta decay (0{\nu}\b{eta}\b{eta}) in 130Te. The CUORE detector consists
of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE
demonstrator: it has been built to test the performance of the upcoming CUORE
experiment and represents the largest 130Te bolometric setup ever operated.
CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from
2013 to 2015. The final CUORE-0 analysis on 0{\nu}\b{eta}\b{eta} and the
corresponding detector performance are presented. The present status of the
CUORE experiment, now in its final construction and commissioning phase, are
discussed. The results from assembly of the detector and the commissioning of
the cryostat are reported.
-
A new generation of cryogenic light detectors exploiting Neganov-Luke effect
to enhance the thermal signal has been used to detect the Cherenkov light
emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism
a high significance event-by-event discrimination between alpha and beta/gamma
interactions at the $^{130}$Te neutrino-less double beta decay Q-value -
(2527.515 $\pm$ 0.013) keV - has been demonstrated. This measurement opens the
possibility of drastically reducing the background in cryogenic experiments
based on TeO$_{2}$.
-
At present the results in the field of direct dark matter search are in
tension: the positive claim of DAMA/LIBRA versus null results from other
experiments. However, the comparison of the results of different experiments
involves model dependencies, in particular because of the different target
materials in use. The COSINUS R&D project aims to operate NaI as a cryogenic
calorimeter. Such a detector would not only allow for a direct comparison to
DAMA/LIBRA, but would also provide a low(er) nuclear recoil threshold and
particle discrimination.
-
The CUORE experiment will search for neutrinoless double-beta decay of
$^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers.
CUORE-0, the first tower assembled according to the CUORE procedures, was built
and commissioned at Laboratori Nazionali del Gran Sasso, and took data from
March 2013 to March 2015. In this paper we describe the design, construction
and operation of the CUORE-0 experiment, with an emphasis on the improvements
made over a predecessor experiment, Cuoricino. In particular, we demonstrate
with CUORE-0 data that the design goals of CUORE are within reach.
-
The R&D activity performed during the last years proved the potential of ZnSe
scintillating bolometers to the search for neutrino-less double beta decay,
motivating the realization of the first large-mass experiment based on this
technology: CUPID-0. The isotopic enrichment in $^{82}$Se, the Zn$^{82}$Se
crystals growth, as well as the light detectors production have been
accomplished, and the experiment is now in construction at Laboratori Nazionali
del Gran Sasso (Italy). In this paper we present the results obtained testing
the first three Zn$^{82}$Se crystals operated as scintillating bolometers, and
we prove that their performance in terms of energy resolution, background
rejection capability and intrinsic radio-purity complies with the requirements
of CUPID-0.
-
We describe in detail the methods used to obtain the lower bound on the
lifetime of neutrinoless double-beta ($0\nu\beta\beta$) decay in $^{130}$Te and
the associated limit on the effective Majorana mass of the neutrino using the
CUORE-0 detector. CUORE-0 is a bolometric detector array located at the
Laboratori Nazionali del Gran Sasso that was designed to validate the
background reduction techniques developed for CUORE, a next-generation
experiment scheduled to come online in 2016. CUORE-0 is also a competitive
$0\nu\beta\beta$ decay search in its own right and functions as a platform to
further develop the analysis tools and procedures to be used in CUORE. These
include data collection, event selection and processing, as well as an
evaluation of signal efficiency. In particular, we describe the amplitude
evaluation, thermal gain stabilization, energy calibration methods, and the
analysis event selection used to create our final $0\nu\beta\beta$ decay search
spectrum. We define our high level analysis procedures, with emphasis on the
new insights gained and challenges encountered. We outline in detail our
fitting methods near the hypothesized $0\nu\beta\beta$ decay peak and catalog
the main sources of systematic uncertainty. Finally, we derive the
$0\nu\beta\beta$ decay half-life limits previously reported for CUORE-0,
$T^{0\nu}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino
limit, $T^{0\nu}_{1/2}>4.0\times10^{24}$ yr.
-
The R&D project COSINUS (Cryogenic Observatory for SIgnatures seen in
Next-generation Underground Searches) aims to develop a cryogenic scintillating
calorimeter using NaI as target crystal for direct darkmatter search. Dark
matter particles interacting with the detector material generate both a phonon
signal and scintillation light. While the phonon signal provides a precise
determination of the deposited energy, the simultaneously measured
scintillation light allows for a particle identification on an event-by-event
basis, a powerful tool to study material-dependent interactions, and to
suppress backgrounds. Using the same target material as the DAMA/LIBRA
collaboration, the COSINUS technique may offer a unique possibility to
investigate and contribute information to the presently controversial situation
in the dark matter sector. We report on the dedicated design planned for the
NaI proof-of-principle detector and the objectives of using this detection
technique in the light of direct dark matter detection.
-
Cryogenic detectors have a long history of success in the field of rare event
searches. In particular scintillating calorimeters are very suitable detectors
for this task since they provide particle discrimination: the simultaneous
detection of the thermal and the light signal produced by a particle
interaction in scintillating crystals allows to identify the nature of
particle, as the light yield depends thereon. We investigate the performance of
two large CsI (undoped) crystals ($\sim$122 g each) operated as scintillating
calorimeters at milli-Kelvin temperatures in terms of calorimetric properties
and background rejection capabilities. Furthermore, we discuss the feasibility
of this detection approach towards a background-free future dark matter
experiment based on alkali halides crystals, with active particle
discrimination via the two-channel detection.
-
The LUCIFER project aims at deploying the first array of enriched
scintillating bolometers for the investigation of neutrinoless double-beta
decay of $^{82}$Se. The matrix which embeds the source is an array of ZnSe
crystals, where enriched $^{82}$Se is used as decay isotope. The radiopurity of
the initial components employed for manufacturing crystals, that can be
operated as bolometers, is crucial for achieving a null background level in the
region of interest for double-beta decay investigations. In this work, we
evaluated the radioactive content in 2.5 kg of 96.3\% enriched $^{82}$Se metal,
measured with a high-purity germanium detector at the Gran Sasso deep
underground laboratory. The limits on internal contaminations of primordial
decay chain elements of $^{232}$Th, $^{238}$U and $^{235}$U are respectively:
$<$61 $\mu$Bq/kg, $< $110 $\mu$Bq/kg and $<$74 $\mu$Bq/kg at 90\% C.L.. The
extremely low-background conditions in which the measurement was carried out
and the high radiopurity of the $^{82}$Se allowed us to establish the most
stringent lower limits on the half-lives of double-beta decay of $^{82}$Se to
0$^+_1$, 2$^+_2$ and 2$^+_1$ excited states of $^{82}$Kr of 3.4$\cdot$10$^{22}$
y, 1.3$\cdot$10$^{22}$ y and 1.0$\cdot$10$^{22}$ y, respectively, with a 90\%
C.L..
-
Next generation calorimetric experiments for the search of rare events rely
on the detection of tiny amounts of light (of the order of 20 optical photons)
to discriminate and reduce background sources and improve sensitivity.
Calorimetric detectors are the simplest solution for photon detection at
cryogenic (mK) temperatures. The development of silicon based light detectors
with enhanced performance thanks to the use of the Neganov-Luke effect is
described. The aim of this research line is the production of high performance
detectors with industrial-grade reproducibility and reliability.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is an
experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) in
$^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of
988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being
constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will
start taking data in 2015. If the target background of 0.01
counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking
CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\%
C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to
test and demonstrate the performances expected for CUORE, has been assembled
and is running. The detector is a single tower of 52 CUORE-like bolometers that
started taking data in spring 2013. The status and perspectives of CUORE will
be discussed, and the first CUORE-0 data will be presented.
-
Neutrinoless double-beta ($0\nu\beta\beta$) decay is a hypothesized
lepton-number-violating process that offers the only known means of asserting
the possible Majorana nature of neutrino mass. The Cryogenic Underground
Observatory for Rare Events (CUORE) is an upcoming experiment designed to
search for $0\nu\beta\beta$ decay of $^{130}$Te using an array of 988 TeO$_2$
crystal bolometers operated at 10 mK. The detector will contain 206 kg of
$^{130}$Te and have an average energy resolution of 5 keV; the projected
$0\nu\beta\beta$ decay half-life sensitivity after five years of live time is
$1.6\times 10^{26}$ y at $1\sigma$ ($9.5\times10^{25}$ y at the 90% confidence
level), which corresponds to an upper limit on the effective Majorana mass in
the range 40--100 meV (50--130 meV). In this paper we review the experimental
techniques used in CUORE as well as its current status and anticipated physics
reach.
-
CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless
double beta decay of 130Te. The detector is being constructed at the Laboratori
Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If
the target background of 0.01 counts/keV/kg/y will be reached, in five years of
data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0
is a smaller experiment constructed to test and demonstrate the performances
expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers
that started taking data in spring 2013. The status and perspectives of CUORE
will be discussed, and the first CUORE-0 data will be presented.