-
The TT-PET collaboration is developing a PET scanner for small animals with
30 ps time-of-flight resolution and sub-millimetre 3D detection granularity.
The sensitive element of the scanner is a monolithic silicon pixel detector
based on state-of-the-art SiGe BiCMOS technology. The first ASIC prototype for
the TT-PET was produced and tested in the laboratory and with minimum ionizing
particles. The electronics exhibit an equivalent noise charge below 600 e- RMS
and a pulse rise time of less than 2 ns, in accordance with the simulations.
The pixels with a capacitance of 0.8 pF were measured to have a detection
efficiency greater than 99% and, although in the absence of the
post-processing, a time resolution of approximately 200 ps.
-
This paper has the purpose to study the rate capability of the Resistive
Plate Chamber, RPC, starting from the basic physics of this detector. The
effect of different working parameters determining the rate capability is
analysed in detail, in order to optimize a new family of RPCs for applications
to heavy irradiation environments and in particular to the LHC phase 2. A
special emphasis is given to the improvement achievable by minimizing the
avalanche charge delivered in the gas. The paper shows experimental results of
Cosmic Ray tests, performed to study the avalanche features for different gas
gap sizes, with particular attention to the overall delivered charge. For this
purpose, the paper studies, in parallel to the prompt electronic signal, also
the ionic signal which gives the main contribution to the delivered charge.
Whenever possible the test results are interpreted on the base of the RPC
detector physics and are intended to extend and reinforce our physical
understanding of this detector.
-
We report on studies of fast triggering and high-precision tracking using
Resistive Plate Chambers (RPCs). Two beam tests were carried out with the 180
GeV muon beam at CERN using RPCs with gas gaps of 1.00 or 1.15 mm and equipped
with readout strips with 1.27 mm pitch. This is the first beam test of RPCs
with fine-pitch readout strips that explores simultaneously precision tracking
and triggering capabilities. RPC signals were acquired with precision timing
and charge integrating readout electronics at both ends of the strips. The time
resolution was measured to be better than 600 ps and the average spatial
resolution was found to be 220 um using charge information and 287 um using
timing information. The dual-ended readout allows the determination of the
average and the difference of the signal arrival times. The average time was
found to be independent of the incident particle position along the strip and
is useful for triggering purposes. The time difference yielded a determination
of the hit position with a precision of 7.5 mm along the strip. These results
demonstrate the feasibility using RPCs for fast and high-resolution triggering
and tracking.