• Aiming at high precision beam position measurement of micron or sub-micron for Shanghai Soft X-ray free electron laser (SXFEL) facility which is being built in site of the Shanghai Synchrotron Radiation Facility (SSRF), Shanghai Institute of Applied Physics has developed a high Q cavity beam position monitor (CBPM) that the resonant frequency is 4.7 GHz and relevant BPM electronics include dedicated RF front-end and home-made digital BPM (DBPM) also has been done. The cavity design, cold test, system architecture and the beam test with three adjacent pickups has been performed in Shanghai Deep ultraviolet free electron laser(SDUV-FEL) facility are included. The beam experiment results show that the physical design of our CBPM is consistent with the expectations basically and the beam position resolution can fulfill the resolution requirements for the SXFEL project if we optimize the beam conditions.
  • The stabilities of the beam and machine have almost the highest priority in a modern light source. Although a lot of machine parameters could be used to represent the beam quality, there lacks a single one that could indicate the global information for the machine operators and accelerator physicists, recently. A new parameter has been studied for the last few years as a beam quality flag in Shanghai Synchrotron Radiation Facility (SSRF). Calculations, simulations and detailed analysis of the real-time data from the storage ring had been made and interesting results had confirmed its feasibility.
  • This paper reports the design and cold test of the cavity beam position monitor (CBPM) for SX-FEL to fulfill the requirement of beam position measurement resolution of less than 1{\mu}m, even 0.1{\mu}m. The CBPM was optimized by using a coupling slot to damp the TM010 mode in the output signal. The isolation of TM010 mode is about 117dB, and the shunt impedance is about 200{\Omega}@4.65GHz with the quality factor 80 from MAFIA simulation and test result. A special antenna was designed to load power for reducing excitation of other modes in the cavity. The resulting output power of TM110 mode was about 90mV/mm when the source was 6dBm, and the accomplishable minimum voltage was about 200{\mu}V. The resolution of the CBPM was about 0.1{\mu}m from the linear fitting result based on the cold test.