The GERmanium Detector Array (GERDA) experiment at the Gran Sasso underground
laboratory (LNGS) of INFN is searching for neutrinoless double beta decay of
76Ge. The signature of the signal is a monoenergetic peak at 2039 keV, the
Q-value of the decay, Q_bb. To avoid bias in the signal search, the present
analysis does not consider all those events, that fall in a 40 keV wide region
centered around Q_bb. The main parameters needed for the neutrinoless double
beta decay analysis are described. A background model was developed to describe
the observed energy spectrum. The model contains several contributions, that
are expected on the basis of material screening or that are established by the
observation of characteristic structures in the energy spectrum. The model
predicts a flat energy spectrum for the blinding window around Q_bb with a
background index ranging from 17.6 to 23.8*10^{-3} counts/(keV kg yr). A part
of the data not considered before has been used to test if the predictions of
the background model are consistent. The observed number of events in this
energy region is consistent with the background model. The background at Q-bb
is dominated by close sources, mainly due to 42K, 214Bi, 228Th, 60Co and alpha
emitting isotopes from the 226Ra decay chain. The individual fractions depend
on the assumed locations of the contaminants. It is shown, that after removal
of the known gamma peaks, the energy spectrum can be fitted in an energy range
of 200 kev around Q_bb with a constant background. This gives a background
index consistent with the full model and uncertainties of the same size.
-
Neutrinoless double beta decay is a process that violates lepton number
conservation. It is predicted to occur in extensions of the Standard Model of
particle physics. This Letter reports the results from Phase I of the GERmanium
Detector Array (GERDA) experiment at the Gran Sasso Laboratory (Italy)
searching for neutrinoless double beta decay of the isotope 76Ge. Data
considered in the present analysis have been collected between November 2011
and May 2013 with a total exposure of 21.6 kgyr. A blind analysis is performed.
The background index is about 1.10^{-2} cts/(keV kg yr) after pulse shape
discrimination. No signal is observed and a lower limit is derived for the
half-life of neutrinoless double beta decay of 76Ge, T_1/2 > 2.1 10^{25} yr
(90% C.L.). The combination with the results from the previous experiments with
76Ge yields T_1/2 > 3.0 10^{25} yr (90% C.L.).
-
The GERDA experiment located at the LNGS searches for neutrinoless double
beta (0\nu\beta\beta) decay of ^{76}Ge using germanium diodes as source and
detector. In Phase I of the experiment eight semi-coaxial and five BEGe type
detectors have been deployed. The latter type is used in this field of research
for the first time. All detectors are made from material with enriched ^{76}Ge
fraction. The experimental sensitivity can be improved by analyzing the pulse
shape of the detector signals with the aim to reject background events. This
paper documents the algorithms developed before the data of Phase I were
unblinded. The double escape peak (DEP) and Compton edge events of 2.615 MeV
\gamma\ rays from ^{208}Tl decays as well as 2\nu\beta\beta\ decays of ^{76}Ge
are used as proxies for 0\nu\beta\beta\ decay. For BEGe detectors the chosen
selection is based on a single pulse shape parameter. It accepts 0.92$\pm$0.02
of signal-like events while about 80% of the background events at
Q_{\beta\beta}=2039 keV are rejected.
For semi-coaxial detectors three analyses are developed. The one based on an
artificial neural network is used for the search of 0\nu\beta\beta\ decay. It
retains 90% of DEP events and rejects about half of the events around
Q_{\beta\beta}. The 2\nu\beta\beta\ events have an efficiency of 0.85\pm0.02
and the one for 0\nu\beta\beta\ decays is estimated to be 0.90^{+0.05}_{-0.09}.
A second analysis uses a likelihood approach trained on Compton edge events.
The third approach uses two pulse shape parameters. The latter two methods
confirm the classification of the neural network since about 90% of the data
events rejected by the neural network are also removed by both of them. In
general, the selection efficiency extracted from DEP events agrees well with
those determined from Compton edge events or from 2\nu\beta\beta\ decays.
-
The GERDA collaboration is performing a search for neutrinoless double beta
decay of ^{76}Ge with the eponymous detector. The experiment has been installed
and commissioned at the Laboratori Nazionali del Gran Sasso and has started
operation in November 2011. The design, construction and first operational
results are described, along with detailed information from the R&D phase.
-
The primary goal of the GERmanium Detector Array (Gerda) experiment at the
Laboratori Nazionali del Gran Sasso of INFN is the search for the neutrinoless
double beta decay of Ge-76. High-purity germanium detectors made from material
enriched in Ge-76 are operated directly immersed in liquid argon, allowing for
a substantial reduction of the background with respect to predecessor
experiments. The first 5.04 kg yr of data collected in Phase I of the
experiment have been analyzed to measure the half-life of the
neutrino-accompanied double beta decay of Ge-76. The observed spectrum in the
energy range between 600 and 1800 keV is dominated by the double beta decay of
Ge-76. The half-life extracted from Gerda data is T(1/2) = (1.84 +0.14 -0.10)
10^{21} yr.
-
The GERDA (GERmanium Detector Array) experiment aiming to search for the
neutrinoless double beta decay of 76Ge at the Laboratori Nazionali Del Gran
Sasso (LNGS), Italy, will operate bare enriched high-purity germanium (HPGe)
detectors in liquid argon. GERDA Phase I will use the enriched diodes from the
previous Heidelberg-Moscow (HdM) and IGEX experiments. With the HPGe detectors
mounted in a low-mass holder, GERDA aims at an excellent energy resolution and
extremely low background. The goal is to check the claim for the neutrinoless
double beta decay evidence in the HdM 76Ge experiment within one year of data
taking. Before dismounting the enriched diodes from their cryostat, the
performance parameters of the HdM and the IGEX detectors have been measured.
The diodes have been removed from their cryostats, their dimensions measured
and they have been put under va-cuum in a transportation container. They are
now being refurbished for GERDA Phase I at Canberra Semiconductor NV. Before
operating the enriched diodes, a non-enriched HPGe p-type detector mounted in a
low-mass holder is operated in the liquid argon test facility of the GERDA
Detector Laboratory (GDL) at LNGS. Since January 2006, the testing of the
prototype detector is being carried out in the GDL as well as at the site of
the detector manufacturer.