  • Fiber Bragg Grating sensors for deformation monitoring of GEM foils in HEP detectors (1512.08629)

    L. Benussi, S. Bianco, M. Caponero, S. Muhammad, L. Passamonti, D. Piccolo, D. Pierluigi, G. Raffone, A. Russo, G. Saviano
    Dec. 29, 2015 physics.ins-det
    Fiber Bragg Grating (FBG) sensors have been so far mainly used in high energy physics (HEP) as high precision positioning and re-positioning sensors and as low cost, easy to mount, radiation hard and low space- consuming temperature and humidity devices. FBGs are also commonly used for very precise strain measurements. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide Gas Electron Multiplier (GEM) foils of the GE1/1 chambers of the Compact Muon Solenoid (CMS) experiment at Large Hadron Collider (LHC) of CERN. A network of FBG sensors has been used to determine the optimal mechanical tension applied and to characterize the mechanical stress applied to the foils. The preliminary results of the test performed on a full size GE1/1 final prototype and possible future developments will be discussed.
  • Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors (1512.08481)

    D. Abbaneo, M. Abbas, M. Abbrescia, A.A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, A. Braghieri, S. Braibant, S. Buontempo, C. Calabria, M. Caponero, C. Caputo, F. Cassese, A. Castaneda, S. Cauwenbergh, F.R. Cavallo, A. Celik, M. Choi, S. Choi, J. Christiansen, A. Cimmino, S. Colafranceschi, A. Colaleo, A. Conde Garcia, S. Czellar, M.M. Dabrowski, G. De Lentdecker, R. De Oliveira, G. de Robertis, S. Dildick, B. Dorney, W. Elmetenawee, G. Endroczi, F. Errico, A. Fenyvesi, S. Ferry, I. Furic, P. Giacomelli, V. Golovtsov, L. Guiducci, F. Guilloux, A. Gutierrez, R.M. Hadjiiska, A. Hassan, J. Hauser, K. Hoepfner, M. Hohlmann, H. Hoorani, P. Iaydjiev, Y.G. Jeng, T. Kamon, P. Karchin, A. Korytov, S. Krutelyov, A. Kumar, H. Kim, J. Lee, T. Lenzi, L. Litov, F. Loddo, A. Madorsky, T. Maerschalk, M. Maggi, A. Magnani, P.K. Mal, K. Mandal, A. Marchioro, A. Marinov, R. Masod, N. Majumdar, J.A. Merlin, G. Mitselmakher, A.K. Mohanty, S. Muhammad, A. Mohapatra, J. Molnar, S. Mukhopadhyay, M. Naimuddin, S. Nuzzo, E. Oliveri, L.M. Pant, P. Paolucci, I. Park, G. Passeggio, L. Passamonti, B. Pavlov, B. Philipps, D. Piccolo, D. Pierluigi, H. Postema, A. Puig Baranac, A. Radi, R. Radogna, G. Raffone, A. Ranieri, G. Rashevski, C. Riccardi, M. Rodozov, A. Rodrigues, L. Ropelewski, S. RoyChowdhury, A. Russo, G. Ryu, M.S. Ryu, A. Safonov, S. Salva, G. Saviano, A. Sharma, A. Sharma, R. Sharma, A.H. Shah, M. Shopova, J. Sturdy, G. Sultanov, S.K. Swain, Z. Szillasi, A. Tatarinov, T. Tuuva, M. Tytgat, I. Vai, M. Van Stenis, R. Venditti, E. Verhagen, P. Verwilligen, P. Vitulo, S. Volkov, A. Vorobyev, D. Wang, M. Wang, U. Yang, Y. Yang, R. Yonamine, N. Zaganidis, F. Zenoni, A. Zhang
    Dec. 28, 2015 physics.ins-det
    ... ... ... ... ... ...
    A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
  • A novel application of Fiber Bragg Grating (FBG) sensors in MPGD (1512.08529)

    D. Abbaneo, M. Abbas, M. Abbrescia, A.A. Abdelalim, M. Abi Akl, O. Aboamer, D. Acosta, A. Ahmad, W. Ahmed, W. Ahmed, A. Aleksandrov, R. Aly, P. Altieri, C. Asawatangtrakuldee, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, V. Barashko, P. Barria, G. Bencze, N. Beni, L. Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, A. Braghieri, S. Braibant, S. Buontempo, C. Calabria, M. Caponero, C. Caputo, F. Cassese, A. Castaneda, S. Cauwenbergh, F.R. Cavallo, A. Celik, M. Choi, S. Choi, J. Christiansen, A. Cimmino, S. Colafranceschi, A. Colaleo, A. Conde Garcia, S. Czellar, M.M. Dabrowski, G. De Lentdecker, R. De Oliveira, G. de Robertis, S. Dildick, B. Dorney, W. Elmetenawee, G. Endroczi, F. Errico, A. Fenyvesi, S. Ferry, I. Furic, P. Giacomelli, V. Golovtsov, L. Guiducci, F. Guilloux, A. Gutierrez, R.M. Hadjiiska, A. Hassan, J. Hauser, K. Hoepfner, M. Hohlmann, H. Hoorani, P. Iaydjiev, Y.G. Jeng, T. Kamon, P. Karchin, A. Korytov, S. Krutelyov, A. Kumar, H. Kim, J. Lee, T. Lenzi, L. Litov, F. Loddo, A. Madorsky, T. Maerschalk, M. Maggi, A. Magnani, P.K. Mal, K. Mandal, A. Marchioro, A. Marinov, R. Masod, N. Majumdar, J.A. Merlin, G. Mitselmakher, A.K. Mohanty, S. Muhammad, A. Mohapatra, J. Molnar, S. Mukhopadhyay, M. Naimuddin, S. Nuzzo, E. Oliveri, L.M. Pant, P. Paolucci, I. Park, G. Passeggio, L. Passamonti, B. Pavlov, B. Philipps, D. Piccolo, D. Pierluigi, H. Postema, A. Puig Baranac, A. Radi, R. Radogna, G. Raffone, A. Ranieri, G. Rashevski, C. Riccardi, M. Rodozov, A. Rodrigues, L. Ropelewski, S. RoyChowdhury, A. Russo, G. Ryu, M.S. Ryu, A. Safonov, S. Salva, G. Saviano, A. Sharma, A. Sharma, R. Sharma, A.H. Shah, M. Shopova, J. Sturdy, G. Sultanov, S.K. Swain, Z. Szillasi, A. Tatarinov, T. Tuuva, M. Tytgat, I. Vai, M. Van Stenis, R. Venditti, E. Verhagen, P. Verwilligen, P. Vitulo, S. Volkov, A. Vorobyev, D. Wang, M. Wang, U. Yang, Y. Yang, R. Yonamine, N. Zaganidis, F. Zenoni, A. Zhang
    Dec. 28, 2015 physics.ins-det
    ... ... ... ... ... ...
    We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
  • Performance of a Large-Area GEM Detector Prototype for the Upgrade of the CMS Muon Endcap System (1412.0228)

    D.Abbaneo, M. Abbas, M. Abbrescia, A.A. Abdelalim, M. Abi Akl, W. Ahmed, W. Ahmed, P. Altieri, R. Aly, C. Asawatangtrakuldee, A. Ashfaq, P. Aspell, Y. Assran, I. Awan, S. Bally, Y. Ban, S. Banerjee, P. Barria, L.Benussi, V. Bhopatkar, S. Bianco, J. Bos, O. Bouhali, S. Braibant, S. Buontempo, C. Calabria, M. Caponero, C. Caputo, F. Cassese, A. Castaneda, S. Cauwenbergh, F.R. Cavallo, A. Celik, M. Choi, K. Choi, S. Choi, J. Christiansen, A. Cimmino, S. Colafranceschi, A. Colaleo, A. Conde Garcia, M.M.Dabrowski, G. De Lentdecker, R. De Oliveira, G.de Robertis, S. Dildick, B.Dorney, W. Elmetenawee, G. Fabrice, M. Ferrini, S. Ferry, P. Giacomelli, J. Gilmore, L. Guiducci, A. Gutierrez, R.M. Hadjiiska, A. Hassan, J. Hauser, K. Hoepfner, M. Hohlmann, H. Hoorani, Y.G. Jeng, T. Kamon, P.E. Karchin, H.S. Kim, S. Krutelyov, A. Kumar, J. Lee, T. Lenzi, L. Litov, F. Loddo, T. Maerschalk, G. Magazzu, M. Maggi, Y. Maghrbi, A. Magnani, N. Majumdar, P.K. Mal, K. Mandal, A. Marchioro, A. Marinov, J.A. Merlin, A.K. Mohanty, A. Mohapatra, S. Muhammad, S. Mukhopadhyay, M. Naimuddin, S. Nuzzo, E. Oliveri, L.M. Pant, P. Paolucci, I. Park, G. Passeggio, B. Pavlov, B. Philipps, M. Phipps, D. Piccolo, H. Postema, G. Pugliese, A. Puig Baranac, A. Radi, R. Radogna, G. Raffone, S. Ramkrishna, A. Ranieri, C. Riccardi, A. Rodrigues, L. Ropelewski, S. RoyChowdhury, M.S. Ryu, G. Ryu, A. Safonov, A. Sakharov, S. Salva, G. Saviano, A. Sharma, S.K. Swain, J.P. Talvitie, C. Tamma, A. Tatarinov, N. Turini, T. Tuuva, J. Twigger, M. Tytgat, I. Vai, M. van Stenis, R. Venditi, E. Verhagen, P. Verwilligen, P. Vitulo, D. Wang, M. Wang, U. Yang, Y. Yang, R. Yonamine, N. Zaganidis, F. Zenoni, A. Zhang
    Dec. 8, 2014 physics.ins-det
    ... ... ... ... ... ...
    Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid\eta\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $\mu$rad pitch arranged in eight $\eta$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $\mu$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $\mu$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $\mu$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $\mu$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $\mu$rad. Other $\eta$-sectors of the detector show similar response and performance.
  • The Upgrade of the CMS RPC System during the First LHC Long Shutdown (1209.1979)

    M. Tytgat, A. Marinov, P. Verwilligen, N. Zaganidis, A. Aleksandrov, V. Genchev, P. Iaydjiev, M. Rodozov, M. Shopova, G. Sultanov, Y. Assran, M. Abbrescia, C. Calabria, A. Colaleo, G. Iaselli, F. Loddo, M. Maggi, G. Pugliese, L. Benussi, S. Bianco, M. Caponero, S. Colafranceschi, F. Felli, D. Piccolo, G. Saviano, C. Carrillo, U. Berzano, M. Gabusi, P. Vitulo, M. Kang, K. S. Lee, S. K. Park, S. Shin, A. Sharma
    Sept. 10, 2012 hep-ex, physics.ins-det
    ... ... ... ... ... ...
    The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value of 10^34/cm^2/s at 14 TeV. To prepare the machine and also the experiments for this, two long shutdown periods are scheduled for 2013-2014 and 2018-2019. The CMS Collaboration is planning several detector upgrades during these long shutdowns. In particular, the muon detection system should be able to maintain a low-pT threshold for an efficient Level-1 Muon Trigger at high particle rates. One of the measures to ensure this, is to extend the present RPC system with the addition of a 4th layer in both endcap regions. During the first long shutdown, these two new stations will be equipped in the region |eta|<1.6 with 144 High Pressure Laminate (HPL) double-gap RPCs operating in avalanche mode, with a similar design as the existing CMS endcap chambers. Here, we present the upgrade plans for the CMS RPC system for the fist long shutdown, including trigger simulation studies for the extended system, and details on the new HPL production, the chamber assembly and the quality control procedures.