We present the first measurements of the muon-induced neutron flux at the
Boulby Underground Laboratory. The experiment was carried out with an 0.73
tonne liquid scintillator that also served as an anticoincidence system for the
ZEPLIN-II direct dark matter search. The experimental method exploited the
delayed coincidences between high-energy muon signals and gamma-rays from
radiative neutron capture on hydrogen or other elements. The muon-induced
neutron rate, defined as the average number of detected neutrons per detected
muon, was measured as $0.079 \pm 0.003$ (stat.) neutrons/muon using
neutron-capture signals above 0.55 MeV in a time window of 40-190 $\mu$s after
the muon trigger. Accurate Monte Carlo simulations of the neutron production,
transport and detection in a precisely modeled laboratory and experimental
setup using the GEANT4 toolkit gave a result 1.8 times higher than the measured
value. The difference greatly exceeds all statistical and systematic
uncertainties. As the vast majority of neutrons detected in the current setup
were produced in lead we evaluated from our measurements the neutron yield in
lead as $(1.31 \pm 0.06) \times 10^{-3}$ neutrons/muon/(g/cm$^2$) for a mean
muon energy of about 260 GeV.
-
We propose a new concept for a very low background multi-ton liquid xenon
Dark Matter experiment. The detector consists of two concentric spheres and a
charge readout device in the centre. Xenon between the two spheres forms a
self-shield and veto device. The inner surface of the central sphere is coated
with CsI to form an internal photocathode with minimum of 2\pi coverage for any
event in the active volume. Photoelectrons from the CsI photocathode drift
toward the charge readout micro-structure in the centre of the detector. Both
scintillation and ionisation are measured simultaneously for background
rejection and 3-D event mapping. In addition to external shielding, the low
background is achieved by eliminating PMTs and by using low radioactivity pure
materials throughout the detector. We present detailed calculations of the
charge readout system and design details. The detector is expected to probe the
full SUSY parameter space.
-
Results are presented from the first underground data run of ZEPLIN-II, a 31
kg two phase xenon detector developed to observe nuclear recoils from
hypothetical weakly interacting massive dark matter particles. Discrimination
between nuclear recoils and background electron recoils is afforded by
recording both the scintillation and ionisation signals generated within the
liquid xenon, with the ratio of these signals being different for the two
classes of event. This ratio is calibrated for different incident species using
an AmBe neutron source and Co-60 gamma-ray sources. From our first 31 live days
of running ZEPLIN-II, the total exposure following the application of fiducial
and stability cuts was 225 kgxdays. A background population of radon progeny
events was observed in this run, arising from radon emission in the gas
purification getters, due to radon daughter ion decays on the surfaces of the
walls of the chamber. An acceptance window, defined by the neutron calibration
data, of 50% nuclear recoil acceptance between 5 keVee and 20 keVee, had an
observed count of 29 events, with a summed expectation of 28.6+/-4.3 gamma-ray
and radon progeny induced background events. These figures provide a 90% c.l.
upper limit to the number of nuclear recoils of 10.4 events in this acceptance
window, which converts to a WIMP-nucleon spin-independent cross-section with a
minimum of 6.6x10^-7 pb following the inclusion of an energy dependent,
calibrated, efficiency. A second run is currently underway in which the radon
progeny will be eliminated, thereby removing the background population, with a
projected sensitivity of 2x10^-7 pb for similar exposures as the first run.
-
A technique to measure low intensity fast neutron flux has been developed.
The design, calibrations, procedure for data analysis and interpretation of the
results are discussed in detail. The technique has been applied to measure the
neutron background from rock at the Boulby Underground Laboratory, a site used
for dark matter and other experiments, requiring shielding from cosmic ray
muons. The experiment was performed using a liquid scintillation detector. A
6.1 litre volume stainless steel cell was filled with an in-house made liquid
scintillator loaded with Gd to enhance neutron capture. A two-pulse signature
(proton recoils followed by gammas from neutron capture) was used to identify
the neutron events from much larger gamma background from PMTs. Suppression of
gammas from the rock was achieved by surrounding the detector with high-purity
lead and copper. Calibrations of the detector were performed with various gamma
and neutron sources. Special care was taken to eliminate PMT afterpulses and
correlated background events from the delayed coincidences of two pulses in the
Bi-Po decay chain. A four month run revealed a neutron-induced event rate of
1.84 +- 0.65 (stat.) events/day. Monte Carlo simulations based on the GEANT4
toolkit were carried out to estimate the efficiency of the detector and the
energy spectra of the expected proton recoils. From comparison of the measured
rate with Monte Carlo simulations the flux of fast neutrons from rock was
estimated as (1.72 +- 0.61 (stat.) +- 0.38 (syst.))*10^(-6) cm^(-2) s^(-1)
above 0.5 MeV.
-
We present details of the technical design and manufacture of the ZEPLIN-III
dark matter experiment. ZEPLIN-III is a two-phase xenon detector which measures
both the scintillation light and the ionisation charge generated in the liquid
by interacting particles and radiation. The instrument design is driven by both
the physics requirements and by the technology requirements surrounding the use
of liquid xenon. These include considerations of key performance parameters,
such as the efficiency of scintillation light collection, restrictions placed
on the use of materials to control the inherent radioactivity levels,
attainment of high vacuum levels and chemical contamination control. The
successful solution has involved a number of novel design and manufacturing
features which will be of specific use to future generations of direct dark
matter search experiments as they struggle with similar and progressively more
demanding requirements.
-
We present results from a GEANT4-based Monte Carlo tool for end-to-end
simulations of the ZEPLIN-III dark matter experiment. ZEPLIN-III is a two-phase
detector which measures both the scintillation light and the ionisation charge
generated in liquid xenon by interacting particles and radiation. The software
models the instrument response to radioactive backgrounds and calibration
sources, including the generation, ray-tracing and detection of the primary and
secondary scintillations in liquid and gaseous xenon, and subsequent processing
by data acquisition electronics. A flexible user interface allows easy
modification of detector parameters at run time. Realistic datasets can be
produced to help with data analysis, an example of which is the position
reconstruction algorithm developed from simulated data. We present a range of
simulation results confirming the original design sensitivity of a few times
$10^{-8}$ pb to the WIMP-nucleon cross-section.
-
Presented here are results of simulations of neutron background performed for
a time projection chamber acting as a particle dark matter detector in an
underground laboratory. The investigated background includes neutrons from rock
and detector components, generated via spontaneous fission and (alpha, n)
reactions, as well as those due to cosmic-ray muons. Neutrons were propagated
to the sensitive volume of the detector and the nuclear recoil spectra were
calculated. Methods of neutron background suppression were also examined and
limitations to the sensitivity of a gaseous dark matter detector are discussed.
Results indicate that neutrons should not limit sensitivity to WIMP-nucleon
interactions down to a level of (1 - 3) x 10^{-8} pb in a 10 kg detector.
-
In low background and low threshold particle astrophysics experiments using
observation of Cherenkov or scintillation light it is common to use pairs or
arrays of photomultipliers operated in coincidence. In such circumstances, for
instance in dark matter and neutrino experiments, unexpected PMT noise events
have been observed, probably arising from generation of light from one PMT
being detected by one or more other PMTs. We describe here experimental
investigation of such coincident noise events and development of new techniques
to remove them using novel pulse shape discrimination procedures. When applied
to data from a low background NaI detector with facing PMTs the new procedures
are found to improve noise rejection by a factor of 20 over conventional
techniques, with significantly reduced loss of signal events.
-
Simulations of the neutron background for future large-scale particle dark
matter detectors are presented. Neutrons were generated in rock and detector
elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray
muons. The simulation techniques and results are discussed in the context of
the expected sensitivity of a generic liquid xenon dark matter detector.
Methods of neutron background suppression are investigated. A sensitivity of
$10^{-9}-10^{-10}$ pb to WIMP-nucleon interactions can be achieved by a
tonne-scale detector.
-
The NAIAD experiment (NaI Advanced Detector) for WIMP dark matter searches at
Boulby mine (UK) is described. The detector consists of an array of
encapsulated and unencapsulated NaI(Tl) crystals with high light yield. Six
crystals are collecting data at present. Data accumulated by four of them (10.6
kg x year exposure) have been used to set upper limits on the WIMP-nucleon
spin-independent and WIMP-proton spin-dependent cross-sections. Pulse shape
analysis has been applied to discriminate between nuclear recoils, as may be
caused by WIMP interactions, and electron recoils due to gamma background.
Various calibrations of crystals are presented.
-
The status of dark matter searches with inorganic scintillator detectors at
Boulby mine is reviewed and the results of tests with a CsI(Tl) crystal are
presented. The objectives of the latter experiment were to study anomalous fast
events previously observed and to identify ways to remove this background.
Clear indications were found that these events were due to surface
contamination of crystals by alphas, probably from radon decay. A new array of
unencapsulated NaI(Tl) crystals immersed either in liquid paraffin or pure
nitrogen atmosphere is under construction at Boulby. Such an approach allows
complete control of the surface of the crystals and the ability to remove any
surface contamination. First data from the unencapsulated NaI(Tl) do not show
the presence of anomalous fast events.
-
We analyse ASCA x-ray data and Whipple \gamma-ray data from the blazars
Mkn421 and Mkn501 for short-timescale variability. We find no evidence for
statistically significant (>3\sigma) variability in these data, in either
source, on timescales of less than \sim 10 minutes.
-
Markarian 501, a nearby (z=0.033) X-ray selected BL Lacertae object, is a
well established source of Very High Energy (VHE, E>=300 GeV) gamma rays.
Dramatic variability in its gamma-ray emission on time-scales from years to as
short as two hours has been detected. Multiwavelength observations have also
revealed evidence that the VHE gamma-ray and hard X-ray fluxes may be
correlated. Here we present results of observations made with the Whipple
Collaboration's 10 m Atmospheric Cerenkov Imaging Telescope during 1999 and
discuss them in the context of observations made on Markarian 501 during the
period from 1996-1998.