The CUORE experiment, a ton-scale cryogenic bolometer array, recently began
operation at the Laboratori Nazionali del Gran Sasso in Italy. The array
represents a significant advancement in this technology, and in this work we
apply it for the first time to a high-sensitivity search for a
lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay.
Examining a total TeO$_2$ exposure of 86.3 kg$\cdot$yr, characterized by an
effective energy resolution of (7.7 $\pm$ 0.5) keV FWHM and a background in the
region of interest of (0.014 $\pm$ 0.002) counts/(keV$\cdot$kg$\cdot$yr), we
find no evidence for neutrinoless double-beta decay. The median statistical
sensitivity of this search is $7.0\times10^{24}$ yr. Including systematic
uncertainties, we place a lower limit on the decay half-life of
$T^{0\nu}_{1/2}$($^{130}$Te) > $1.3\times 10^{25}$ yr (90% C.L.). Combining
this result with those of two earlier experiments, Cuoricino and CUORE-0, we
find $T^{0\nu}_{1/2}$($^{130}$Te) > $1.5\times 10^{25}$ yr (90% C.L.), which is
the most stringent limit to date on this decay. Interpreting this result as a
limit on the effective Majorana neutrino mass, we find $m_{\beta\beta}<(110 -
520)$ meV, where the range reflects the nuclear matrix element estimates
employed.
-
Large-area PhotoMultiplier Tubes (PMT) allow to efficiently instrument Liquid
Scintillator (LS) neutrino detectors, where large target masses are pivotal to
compensate for neutrinos' extremely elusive nature. Depending on the detector
light yield, several scintillation photons stemming from the same neutrino
interaction are likely to hit a single PMT in a few tens/hundreds of
nanoseconds, resulting in several photoelectrons (PEs) to pile-up at the PMT
anode. In such scenario, the signal generated by each PE is entangled to the
others, and an accurate PMT charge reconstruction becomes challenging. This
manuscript describes an experimental method able to address the PMT charge
reconstruction in the case of large PE pile-up, providing an unbiased charge
estimator at the permille level up to 15 detected PEs. The method is based on a
signal filtering technique (Wiener filter) which suppresses the noise due to
both PMT and readout electronics, and on a Fourier-based deconvolution able to
minimize the influence of signal distortions ---such as an overshoot. The
analysis of simulated PMT waveforms shows that the slope of a linear regression
modeling the relation between reconstructed and true charge values improves
from $0.769 \pm 0.001$ (without deconvolution) to $0.989 \pm 0.001$ (with
deconvolution), where unitary slope implies perfect reconstruction. A C++
implementation of the charge reconstruction algorithm is available online at
http://www.fe.infn.it/CRA .
-
TeO2 bolometers have been used for many years to search for neutrinoless
double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently
published the most sensitive limit on the half-life, $T_{1/2}^{0\nu} > 1.5
\times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on
the effective Majorana mass of the neutrino. While it makes CUORE a
world-leading experiment looking for neutrinoless double beta decay, it is not
the only study that CUORE will contribute to in the field of nuclear and
particle physics. As already done over the years with many small-scale
experiments, CUORE will investigate both rare decays (such as the two-neutrino
double beta decay of 130-Te and the hypothesized electron capture in 123-Te),
and rare processes (e.g., dark matter and axion interactions). This paper
describes some of the achievements of past experiments that used TeO2
bolometers, and perspectives for CUORE.
-
We have performed a search for neutrinoless $\beta^{+}\hspace{-0.2em}EC$
decay of $^{120}$Te using the final CUORE-0 data release. We describe a new
analysis method for the simultaneous fit of signatures with different event
topology, and of data subsets with different signal efficiency, obtaining a
limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$
CI. Combining this with results from Cuoricino, a predecessor experiment, we
obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$
yr at $90\%$ CI.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to
search for neutrinoless double beta decay of 130Te with an array of 988 TeO2
bolometers operating at temperatures around 10 mK. The experiment is currently
being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The
goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay
half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main
issue to be addressed to accomplish this aim is the rate of background events
in the region of interest, which must not be higher than
10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation,
based on results from a campaign of material screening, radioassays, and
bolometric measurements, to evaluate the expected background. This was used
over the years to guide the construction strategies of the experiment and we
use it here to project a background model for CUORE. In this paper we report
the results of our study and our expectations for the background rate in the
energy region where the peak signature of neutrinoless double beta decay of
130Te is expected.
-
CUORE is a tonne-scale cryogenic detector operating at the Laboratori
Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to
search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable
to search for low energy rare events such as solar axions or WIMP scattering,
thanks to its ultra-low background and large target mass. However, to conduct
such sensitive searches requires improving the energy threshold to 10 keV. In
this paper, we describe the analysis techniques developed for the low energy
analysis of CUORE-like detectors, using the data acquired from November 2013 to
March 2015 by CUORE-0, a single-tower prototype designed to validate the
assembly procedure and new cleaning techniques of CUORE. We explain the energy
threshold optimization, continuous monitoring of the trigger efficiency, data
and event selection, and energy calibration at low energies in detail. We also
present the low energy background spectrum of CUORE-0 below 60keV. Finally, we
report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0
energy threshold and background, as well as an estimate of the uncertainty on
the nuclear quenching factor from nuclear recoils in CUORE-0.
-
We report a study of the CUORE sensitivity to neutrinoless double beta
($0\nu\beta\beta$) decay. We used a Bayesian analysis based on a toy Monte
Carlo (MC) approach to extract the exclusion sensitivity to the
$0\nu\beta\beta$ decay half-life ($T_{1/2}^{0\nu}$) at $90\%$ credibility
interval (CI) -- i.e. the interval containing the true value of
$T_{1/2}^{0\nu}$ with $90\%$ probability -- and the $3 \sigma$ discovery
sensitivity. We consider various background levels and energy resolutions, and
describe the influence of the data division in subsets with different
background levels. If the background level and the energy resolution meet the
expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of
$2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of
live time. Under the same conditions, the discovery sensitivity after $3$
months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr,
respectively.
-
In recent years the scintillation mechanism of inorganic crystals has been
extensively investigated in different studies. The main issues are the
non-proportionality mechanism of the light response versus energy and its
connection with the shaping time used for the scintillation signals. In this
study the Compton coincidence technique has been used to measure the relative
non-proportionality of three crystals: CdWO$_{4}$, BGO, and NaI(Tl). To test
the non-proportionality dependence on shaping time, the preamplified
scintillator pulses have been digitized and shaped with a digital trapezoidal
filter. Since no analogic shaping occurs the majority of the scintillation
components are digitized, thus avoiding major information losses. The obtained
results suggest the existence of a correlation between the time constant of the
scintillation emission and light yield.
-
We report on the measurement of the two-neutrino double beta decay half-life
of $^{130}$Te with the CUORE-0 detector. From an exposure of 33.4 kg$\cdot$y of
TeO$_2$, the half-life is determined to be $T_{1/2}^{2\nu}$ = [8.2 $\pm$ 0.2
(stat.) $\pm$ 0.6 (syst.)] $\times$ 10$^{20}$y. This result is obtained after a
detailed reconstruction of the sources responsible for the CUORE-0 counting
rate, with a specific study of those contributing to the $^{130}$Te
neutrinoless double beta decay region of interest.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton
scale bolometric experiment devoted to the search of the neutrinoless
double-beta decay (0{\nu}\b{eta}\b{eta}) in 130Te. The CUORE detector consists
of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE
demonstrator: it has been built to test the performance of the upcoming CUORE
experiment and represents the largest 130Te bolometric setup ever operated.
CUORE-0 has been running at Laboratori Nazionali del Gran Sasso (Italy) from
2013 to 2015. The final CUORE-0 analysis on 0{\nu}\b{eta}\b{eta} and the
corresponding detector performance are presented. The present status of the
CUORE experiment, now in its final construction and commissioning phase, are
discussed. The results from assembly of the detector and the commissioning of
the cryostat are reported.
-
A new generation of cryogenic light detectors exploiting Neganov-Luke effect
to enhance the thermal signal has been used to detect the Cherenkov light
emitted by the electrons interacting in TeO$_{2}$ crystals. With this mechanism
a high significance event-by-event discrimination between alpha and beta/gamma
interactions at the $^{130}$Te neutrino-less double beta decay Q-value -
(2527.515 $\pm$ 0.013) keV - has been demonstrated. This measurement opens the
possibility of drastically reducing the background in cryogenic experiments
based on TeO$_{2}$.
-
The CUORE experiment will search for neutrinoless double-beta decay of
$^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers.
CUORE-0, the first tower assembled according to the CUORE procedures, was built
and commissioned at Laboratori Nazionali del Gran Sasso, and took data from
March 2013 to March 2015. In this paper we describe the design, construction
and operation of the CUORE-0 experiment, with an emphasis on the improvements
made over a predecessor experiment, Cuoricino. In particular, we demonstrate
with CUORE-0 data that the design goals of CUORE are within reach.
-
We describe in detail the methods used to obtain the lower bound on the
lifetime of neutrinoless double-beta ($0\nu\beta\beta$) decay in $^{130}$Te and
the associated limit on the effective Majorana mass of the neutrino using the
CUORE-0 detector. CUORE-0 is a bolometric detector array located at the
Laboratori Nazionali del Gran Sasso that was designed to validate the
background reduction techniques developed for CUORE, a next-generation
experiment scheduled to come online in 2016. CUORE-0 is also a competitive
$0\nu\beta\beta$ decay search in its own right and functions as a platform to
further develop the analysis tools and procedures to be used in CUORE. These
include data collection, event selection and processing, as well as an
evaluation of signal efficiency. In particular, we describe the amplitude
evaluation, thermal gain stabilization, energy calibration methods, and the
analysis event selection used to create our final $0\nu\beta\beta$ decay search
spectrum. We define our high level analysis procedures, with emphasis on the
new insights gained and challenges encountered. We outline in detail our
fitting methods near the hypothesized $0\nu\beta\beta$ decay peak and catalog
the main sources of systematic uncertainty. Finally, we derive the
$0\nu\beta\beta$ decay half-life limits previously reported for CUORE-0,
$T^{0\nu}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino
limit, $T^{0\nu}_{1/2}>4.0\times10^{24}$ yr.
-
We report the results of a search for neutrinoless double-beta decay in a
9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array,
CUORE-0. The characteristic detector energy resolution and background level in
the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm
0.004\,(\mathrm{stat.})\pm
0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The
median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times
10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find
no evidence for neutrinoless double-beta decay of $^{130}$Te and place a
Bayesian lower bound on the decay half-life, $T^{0\nu}_{1/2}>$~$ 2.7\times
10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr
exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0\nu}_{1/2}
> 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent
limit to date on this half-life. Using a range of nuclear matrix element
estimates we interpret this as a limit on the effective Majorana neutrino mass,
$m_{\beta\beta}< 270$ -- $760~\mathrm{meV}$.
-
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine
the neutrino mass hierarchy using an underground liquid scintillator detector.
It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants
in Guangdong, China. The experimental hall, spanning more than 50 meters, is
under a granite mountain of over 700 m overburden. Within six years of running,
the detection of reactor antineutrinos can resolve the neutrino mass hierarchy
at a confidence level of 3-4$\sigma$, and determine neutrino oscillation
parameters $\sin^2\theta_{12}$, $\Delta m^2_{21}$, and $|\Delta m^2_{ee}|$ to
an accuracy of better than 1%. The JUNO detector can be also used to study
terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard
Model. The central detector contains 20,000 tons liquid scintillator with an
acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high
quantum efficiency provide $\sim$75% optical coverage. The current choice of
the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO
as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of
detected photoelectrons per MeV is larger than 1,100 and the energy resolution
is expected to be 3% at 1 MeV. The calibration system is designed to deploy
multiple sources to cover the entire energy range of reactor antineutrinos, and
to achieve a full-volume position coverage inside the detector. The veto system
is used for muon detection, muon induced background study and reduction. It
consists of a Water Cherenkov detector and a Top Tracker system. The readout
system, the detector control system and the offline system insure efficient and
stable data acquisition and processing.
-
Next generation calorimetric experiments for the search of rare events rely
on the detection of tiny amounts of light (of the order of 20 optical photons)
to discriminate and reduce background sources and improve sensitivity.
Calorimetric detectors are the simplest solution for photon detection at
cryogenic (mK) temperatures. The development of silicon based light detectors
with enhanced performance thanks to the use of the Neganov-Luke effect is
described. The aim of this research line is the production of high performance
detectors with industrial-grade reproducibility and reliability.
-
The Cryogenic Underground Observatory for Rare Events (CUORE) is an
experiment to search for neutrinoless double beta decay ($0\nu\beta\beta$) in
$^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of
988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being
constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will
start taking data in 2015. If the target background of 0.01
counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking
CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\%
C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to
test and demonstrate the performances expected for CUORE, has been assembled
and is running. The detector is a single tower of 52 CUORE-like bolometers that
started taking data in spring 2013. The status and perspectives of CUORE will
be discussed, and the first CUORE-0 data will be presented.
-
The European Research Council has recently funded HOLMES, a new experiment to
directly measure the neutrino mass. HOLMES will perform a calorimetric
measurement of the energy released in the decay of 163Ho. The calorimetric
measurement eliminates systematic uncertainties arising from the use of
external beta sources, as in experiments with beta spectrometers. This
measurement was proposed in 1982 by A. De Rujula and M. Lusignoli, but only
recently the detector technological progress allowed to design a sensitive
experiment. HOLMES will deploy a large array of low temperature
microcalorimeters with implanted 163Ho nuclei. The resulting mass sensitivity
will be as low as 0.4 eV. HOLMES will be an important step forward in the
direct neutrino mass measurement with a calorimetric approach as an alternative
to spectrometry. It will also establish the potential of this approach to
extend the sensitivity down to 0.1 eV. We outline here the project with its
technical challenges and perspectives.
-
Neutrinoless double-beta ($0\nu\beta\beta$) decay is a hypothesized
lepton-number-violating process that offers the only known means of asserting
the possible Majorana nature of neutrino mass. The Cryogenic Underground
Observatory for Rare Events (CUORE) is an upcoming experiment designed to
search for $0\nu\beta\beta$ decay of $^{130}$Te using an array of 988 TeO$_2$
crystal bolometers operated at 10 mK. The detector will contain 206 kg of
$^{130}$Te and have an average energy resolution of 5 keV; the projected
$0\nu\beta\beta$ decay half-life sensitivity after five years of live time is
$1.6\times 10^{26}$ y at $1\sigma$ ($9.5\times10^{25}$ y at the 90% confidence
level), which corresponds to an upper limit on the effective Majorana mass in
the range 40--100 meV (50--130 meV). In this paper we review the experimental
techniques used in CUORE as well as its current status and anticipated physics
reach.
-
With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV
(0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory
for Rare Events) experiment aims at searching for neutrinoless double beta
decay of 130Te with unprecedented sensitivity. Expected to start data taking in
2015, CUORE is currently in an advanced construction phase at LNGS. CUORE
projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1
sigma (9.5E25 y at the 90% confidence level), in five years of live time,
corresponding to an upper limit on the effective Majorana mass in the range
40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric
detectors could improve CUORE sensitivity and competitiveness of bolometric
detectors towards a full analysis of the inverted neutrino mass hierarchy.
CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE
experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g
each, arranged in a 13 floor structure) constructed strictly following CUORE
recipes both for materials and assembly procedures. An experiment its own,
CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta
decay half-life of 130Te around 3E24 y in one year of live time. We present an
update of the data, corresponding to an exposure of 18.1 kg y. An analysis of
the background indicates that the CUORE performance goal is satisfied while the
sensitivity goal is within reach.
-
A search for axioelectric absorption of 5.5 MeV solar axions produced in the
$p + d \rightarrow {^3\rm{He}}+\gamma~(5.5~ \rm{MeV})$ reaction has been
performed with a BGO detectors. A model-independent limit on the product of
axion-nucleon $g_{AN}^3$ and axion-electron $g_{Ae}$ coupling constants has
been obtained: $| g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90\% C.L..
-
A search for axioelectric absorption of solar axions produced in the $ p + d
\rightarrow {^3\rm{He}}+\gamma~(5.5~ \rm{MeV})$ reactions has been performed
with a BGO detector placed in a low-background setup. A model-independent limit
on an axion-nucleon and axion-electron coupling constant has been obtained: $|
g_{Ae}\times g_{AN}^3|< 1.9\times 10^{-10}$ for 90% confidence level. The
constrains of the axion-electron coupling have been obtained for hadronic axion
with masses in (0.1 - 1) MeV range: $|g_{Ae}| \leq (0.96 - 8.2)\times 10^{-8}$.
-
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide
bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present
the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on
background measurements and energy resolution. The background rates in the
neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the
{\alpha} background-dominated region (2.70 to 3.90 MeV) have been measured to
be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The
latter result represents a factor of 6 improvement from a predecessor
experiment, Cuoricino. The results verify our understanding of the background
sources in CUORE-0, which is the basis of extrapolations to the full CUORE
detector. The obtained energy resolution (full width at half maximum) in the
region of interest is 5.7 keV. Based on the measured background rate and energy
resolution in the region of interest, CUORE-0 half-life sensitivity is expected
to surpass the observed lower bound of Cuoricino with one year of live time.
-
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will
search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$
crystals and an excellent energy resolution of 5 keV (0.2%) at the region of
interest, CUORE will be one of the most competitive neutrinoless double beta
decay experiments on the horizon. With five years of live time, CUORE projected
neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y
at $1\sigma$ ($9.5\times10^{25}$ y at the 90% confidence level), which
corresponds to an upper limit on the effective Majorana mass in the range
40--100 meV (50--130 meV). Further background rejection with auxiliary light
detector can significantly improve the search sensitivity and competitiveness
of bolometric detectors to fully explore the inverted neutrino mass hierarchy
with $^{130}$Te and possibly other double beta decay candidate nuclei.
-
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes
for physics beyond the Standard Model, providing unique information on the
nature of neutrinos. In this paper we review the status and outlook for
bolometric 0nubb decay searches. We summarize recent advances in background
suppression demonstrated using bolometers with simultaneous readout of heat and
light signals. We simulate several configurations of a future CUORE-like
bolometer array which would utilize these improvements and present the
sensitivity reach of a hypothetical next-generation bolometric 0nubb
experiment. We demonstrate that a bolometric experiment with the isotope mass
of about 1 ton is capable of reaching the sensitivity to the effective Majorana
neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the
so-called inverted neutrino mass hierarchy region. We highlight the main
challenges and identify priorities for an R&D program addressing them.