Weakly Interacting Massive Particles (WIMPs) are a leading candidate for dark
matter and are expected to produce nuclear recoil (NR) events within liquid
xenon time-projection chambers. We present a measurement of the scintillation
timing characteristics of liquid xenon in the LUX dark matter detector and
develop a pulse shape discriminant to be used for particle identification. To
accurately measure the timing characteristics, we develop a template-fitting
method to reconstruct the detection times of photons. Analyzing calibration
data collected during the 2013-16 LUX WIMP search, we provide a new measurement
of the singlet-to-triplet scintillation ratio for electron recoils (ER) below
46~keV, and we make a first-ever measurement of the NR singlet-to-triplet ratio
at recoil energies below 74~keV. We exploit the difference of the photon time
spectra for NR and ER events by using a prompt fraction discrimination
parameter, which is optimized using calibration data to have the least number
of ER events that occur in a 50\% NR acceptance region. We then demonstrate how
this discriminant can be used in conjunction with the charge-to-light
discrimination to possibly improve the signal-to-noise ratio for nuclear
recoils.
-
The Large Underground Xenon experiment (LUX) searches for dark matter using a
dual-phase xenon detector. LUX uses a custom-developed trigger system for event
selection. In this paper, the trigger efficiency, which is defined as the
probability that an event of interest is selected for offline analysis, is
studied using raw data obtained from both electron recoil (ER) and nuclear
recoil (NR) calibrations. The measured efficiency exceeds 98\% at a pulse area
of 90 detected photons, which is well below the WIMP analysis threshold on the
S2 pulse area. The efficiency also exceeds 98\% at recoil energies of 1.3 keV
and above, for both ER and NR. The measured trigger efficiency varies between
99\% and 100\% over the fiducial volume of the detector.
-
LUX-ZEPLIN (LZ) is a next generation dark matter direct detection experiment
that will operate 4850 feet underground at the Sanford Underground Research
Facility (SURF) in Lead, South Dakota, USA. Using a two-phase xenon detector
with an active mass of 7 tonnes, LZ will search primarily for low-energy
interactions with Weakly Interacting Massive Particles (WIMPs), which are
hypothesized to make up the dark matter in our galactic halo. In this paper,
the projected WIMP sensitivity of LZ is presented based on the latest
background estimates and simulations of the detector. For a 1000 live day run
using a 5.6 tonne fiducial mass, LZ is projected to exclude at 90% confidence
level spin-independent WIMP-nucleon cross sections above $1.6 \times 10^{-48}$
cm$^{2}$ for a 40 $\mathrm{GeV}/c^{2}$ mass WIMP. Additionally, a $5\sigma$
discovery potential is projected reaching cross sections below the existing and
projected exclusion limits of similar experiments that are currently operating.
For spin-dependent WIMP-neutron(-proton) scattering, a sensitivity of $2.7
\times 10^{-43}$ cm$^{2}$ ($8.1 \times 10^{-42}$ cm$^{2}$) for a 40
$\mathrm{GeV}/c^{2}$ mass WIMP is expected. With construction well underway, LZ
is on track for underground installation at SURF in 2019 and will start
collecting data in 2020.
-
The LUX-ZEPLIN (LZ) experiment will search for dark matter particle
interactions with a detector containing a total of 10 tonnes of liquid xenon
within a double-vessel cryostat. The large mass and proximity of the cryostat
to the active detector volume demand the use of material with extremely low
intrinsic radioactivity. We report on the radioassay campaign conducted to
identify suitable metals, the determination of factors limiting radiopure
production, and the selection of titanium for construction of the LZ cryostat
and other detector components. This titanium has been measured with activities
of $^{238}$U$_{e}$~$<$1.6~mBq/kg, $^{238}$U$_{l}$~$<$0.09~mBq/kg,
$^{232}$Th$_{e}$~$=0.28\pm 0.03$~mBq/kg, $^{232}$Th$_{l}$~$=0.25\pm
0.02$~mBq/kg, $^{40}$K~$<$0.54~mBq/kg, and $^{60}$Co~$<$0.02~mBq/kg (68\% CL).
Such low intrinsic activities, which are some of the lowest ever reported for
titanium, enable its use for future dark matter and other rare event searches.
Monte Carlo simulations have been performed to assess the expected background
contribution from the LZ cryostat with this radioactivity. In 1,000 days of
WIMP search exposure of a 5.6-tonne fiducial mass, the cryostat will contribute
only a mean background of $0.160\pm0.001$(stat)$\pm0.030$(sys) counts.
-
The first searches for axions and axion-like particles with the Large
Underground Xenon (LUX) experiment are presented. Under the assumption of an
axio-electric interaction in xenon, the coupling constant between axions and
electrons, gAe is tested, using data collected in 2013 with an exposure
totalling 95 live-days $\times$ 118 kg. A double-sided, profile likelihood
ratio statistic test excludes gAe larger than 3.5 $\times$ 10$^{-12}$ (90%
C.L.) for solar axions. Assuming the DFSZ theoretical description, the upper
limit in coupling corresponds to an upper limit on axion mass of 0.12
eV/c$^{2}$, while for the KSVZ description masses above 36.6 eV/c$^{2}$ are
excluded. For galactic axion-like particles, values of gAe larger than 4.2
$\times$ 10$^{-13}$ are excluded for particle masses in the range 1-16
keV/c$^{2}$. These are the most stringent constraints to date for these
interactions.
-
In this Technical Design Report (TDR) we describe the LZ detector to be built
at the Sanford Underground Research Facility (SURF). The LZ dark matter
experiment is designed to achieve sensitivity to a WIMP-nucleon
spin-independent cross section of three times ten to the negative forty-eighth
square centimeters.
-
This work presents an analysis of monoenergetic electronic recoil peaks in
the dark-matter-search and calibration data from the first underground science
run of the Large Underground Xenon (LUX) detector. Liquid xenon charge and
light yields for electronic recoil energies between 5.2 and 661.7 keV are
measured, as well as the energy resolution for the LUX detector at those same
energies. Additionally, there is an interpretation of existing measurements and
descriptions of electron-ion recombination fluctuations in liquid xenon as
limiting cases of a more general liquid xenon re- combination fluctuation
model. Measurements of the standard deviation of these fluctuations at
monoenergetic electronic recoil peaks exhibit a linear dependence on the number
of ions for energy deposits up to 661.7 keV, consistent with previous LUX
measurements between 2-16 keV with $^3$H. We highlight similarities in liquid
xenon recombination for electronic and nuclear recoils with a comparison of
recombination fluctuations measured with low-energy calibration data.
-
The Large Underground Xenon (LUX) experiment operates at the Sanford
Underground Research Facility to detect nuclear recoils from the hypothetical
Weakly Interacting Massive Particles (WIMPs) on a liquid xenon target. Liquid
xenon typically contains trace amounts of the noble radioactive isotopes
$^{85}$Kr and $^{39}$Ar that are not removed by the {\em in situ} gas
purification system. The decays of these isotopes at concentrations typical of
research-grade xenon would be a dominant background for a WIMP search
exmperiment. To remove these impurities from the liquid xenon, a
chromatographic separation system based on adsorption on activated charcoal was
built. 400\,kg of xenon was processed, reducing the average concentration of
krypton from 130\,ppb to 3.5\,ppt as measured by a cold-trap assisted mass
spectroscopy system. A 50 kg batch spiked to 0.001 g/g of krypton was processed
twice and reduced to an upper limit of 0.2 ppt.
-
LUX is a two-phase (liquid/gas) xenon time projection chamber designed to
detect nuclear recoils resulting from interactions with dark matter particles.
Signals from the detector are processed with an FPGA-based digital trigger
system that analyzes the incoming data in real-time, with just a few
microsecond latency. The system enables first pass selection of events of
interest based on their pulse shape characteristics and 3D localization of the
interactions. It has been shown to be >99% efficient in triggering on S2
signals induced by only few extracted liquid electrons. It is continuously and
reliably operating since its full underground deployment in early 2013. This
document is an overview of the systems capabilities, its inner workings, and
its performance.
-
The Large Underground Xenon (LUX) dark matter experiment aims to detect rare
low-energy interactions from Weakly Interacting Massive Particles (WIMPs). The
radiogenic backgrounds in the LUX detector have been measured and compared with
Monte Carlo simulation. Measurements of LUX high-energy data have provided
direct constraints on all background sources contributing to the background
model. The expected background rate from the background model for the 85.3 day
WIMP search run is
$(2.6\pm0.2_{\textrm{stat}}\pm0.4_{\textrm{sys}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$
in a 118~kg fiducial volume. The observed background rate is
$(3.6\pm0.4_{\textrm{stat}})\times10^{-3}$~events~keV$_{ee}^{-1}$~kg$^{-1}$~day$^{-1}$,
consistent with model projections. The expectation for the radiogenic
background in a subsequent one-year run is presented.
-
LUX, the world's largest dual-phase xenon time-projection chamber, with a
fiducial target mass of 118 kg and 10,091 kg-days of exposure thus far, is
currently the most sensitive direct dark matter search experiment. The initial
null-result limit on the spin-independent WIMP-nucleon scattering cross-section
was released in October 2013, with a primary scintillation threshold of 2 phe,
roughly 3 keVnr for LUX. The detector has been deployed at the Sanford
Underground Research Facility (SURF) in Lead, South Dakota, and is the first
experiment to achieve a limit on the WIMP cross-section lower than $10^{-45}$
cm$^{2}$. Here we present a more in-depth discussion of the novel energy scale
employed to better understand the nuclear recoil light and charge yields, and
of the calibration sources, including the new internal tritium source. We found
the LUX data to be in conflict with low-mass WIMP signal interpretations of
other results.
-
The Large Underground Xenon (LUX) experiment, a dual-phase xenon
time-projection chamber operating at the Sanford Underground Research Facility
(Lead, South Dakota), was cooled and filled in February 2013. We report results
of the first WIMP search dataset, taken during the period April to August 2013,
presenting the analysis of 85.3 live-days of data with a fiducial volume of 118
kg. A profile-likelihood analysis technique shows our data to be consistent
with the background-only hypothesis, allowing 90% confidence limits to be set
on spin-independent WIMP-nucleon elastic scattering with a minimum upper limit
on the cross section of $7.6 \times 10^{-46}$ cm$^{2}$ at a WIMP mass of 33
GeV/c$^2$. We find that the LUX data are in strong disagreement with low-mass
WIMP signal interpretations of the results from several recent direct detection
experiments.