The CALICE Semi-Digital Hadron Calorimeter (SDHCAL) technological prototype
is a sampling calorimeter using Glass Resistive Plate Chamber detectors with a
three-threshold readout as the active medium. This technology is one of the two
options proposed for the hadron calorimeter of the International Large Detector
for the International Linear Collider. The prototype was exposed to beams of
muons, electrons and pions of different energies at the CERN Super Proton
Synchrotron. To be able to study the performance of such a calorimeter in
future experiments it is important to ensure reliable simulation of its
response. In this paper we present our prototype simulation performed with
GEANT4 and the digitization procedure achieved with an algorithm called
SimDigital. A detailed description of this algorithm is given and the methods
to determinate its parameters using muon tracks and electromagnetic showers are
explained. The comparison with hadronic shower data shows a good agreement up
to 50 GeV. Discrepancies are observed at higher energies. The reasons for these
differences are investigated.
-
Calorimeters with a high granularity are a fundamental requirement of the
Particle Flow paradigm. This paper focuses on the prototype of a hadron
calorimeter with analog readout, consisting of thirty-eight scintillator layers
alternating with steel absorber planes. The scintillator plates are finely
segmented into tiles individually read out via Silicon Photomultipliers. The
presented results are based on data collected with pion beams in the energy
range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and
the high sampling frequency allow for an excellent reconstruction of the
spatial development of hadronic showers. A comparison between data and Monte
Carlo simulations is presented, concerning both the longitudinal and lateral
development of hadronic showers and the global response of the calorimeter. The
performance of several GEANT4 physics lists with respect to these observables
is evaluated.
-
A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector
was tested in 2007 at the CERN SPS test beam. Data were collected with electron
and hadron beams in the energy range 8 to 80 GeV. The analysis described here
focuses on the interactions of pions in the calorimeter. One of the main
objectives of the CALICE program is to validate the Monte Carlo tools available
for the design of a full-sized detector. The interactions of pions in the Si-W
calorimeter are therefore confronted with the predictions of various physical
models implemented in the GEANT4 simulation framework.